Gold nanoparticle enhanced proton therapy: A Monte Carlo simulation of the effects of proton energy, nanoparticle size, coating material, and coating thickness on dose and radiolysis yield.

Abstract:

PURPOSE:Radiosensitizer enhanced radiotherapy provides the possibility of improved treatment outcomes by preferentially increasing the effectiveness of radiation within the tumor. Proton therapy offers improved sparing of tissue distal of the tumor along the beam path and reduced integral dose compared to conventional photon therapy. The combination of proton therapy with radiosensitizers offers the potential for an enhanced therapy with increased effect within the tumor and low integral dose. The simulations performed in this work determine the effect of nanoparticle characteristics and proton energy on the nanoscale dose and radiolysis yield enhancement for a single gold nanoparticle irradiated with a proton beam. This data can be used to determine optimal nanoparticle characteristics to enhance proton therapy. METHODS:A two-stage Monte Carlo simulation was performed using Geant4. In the first stage of the simulation, the physical interactions of protons within a gold nanoparticle were modeled and the secondary electrons escaping the nanoparticle's surface were scored in a phase space file. In the second stage of the simulation, the phase space file was used as an input to model the physical interactions of the secondary electrons in water and the resulting production and chemical interactions of reactive species. By comparing a gold nanoparticle with an equivalent water nanoparticle, the nanoscale enhancement of dose and radiolysis yield was calculated. RESULTS:A large nanoscale enhancement of both the dose and radiolysis yield of up to a factor of 11 due to gold nanoparticles was found for most simulated conditions. For 50 nm gold nanoparticles, a large enhancement factor of 9-11 was observed for high proton energies; however, the enhancement was reduced for proton energies below 10 MeV. For 5 MeV incident protons, it was found that the enhancement factor was approximately 9 for gold nanoparticles of sizes 5-25 nm with a reduction in enhancement observed for nanoparticle sizes outside this range. Additionally, it was found that larger nanoparticle sizes resulted in greater total energy deposition and radiolysis yields per proton flux but with reduced efficiency per nanoparticle mass. It was observed that a large loss of enhancement occurred for thick nanoparticle coatings. However, for polyethylene glycol (PEG) coatings, coating density had a minimal effect on enhancement. CONCLUSIONS:A large enhancement in dose and radiolysis yield was observed. However, the low-energy secondary electrons produced within the gold for lower energy protons are susceptible to self-absorption and result in the loss of enhancement observed for larger nanoparticles and thicker coatings. The radiolysis yield and dose increase with nanoparticle size; however, the yield and dose per gold mass decrease due to self-absorption. Therefore, an intermediate nanoparticle size of approximately 10-25 nm maximizes both the radiolysis yield and dose as well as the enhancement. Coatings should be kept to the minimum effective thickness to limit the loss of enhancement. For molecular coatings such as PEG, coating density should be maximized as this increases the coating's effectiveness with only a minimal effect on enhancement.

journal_name

Med Phys

journal_title

Medical physics

authors

Peukert D,Kempson I,Douglass M,Bezak E

doi

10.1002/mp.13923

subject

Has Abstract

pub_date

2020-02-01 00:00:00

pages

651-661

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • Rapid in vivo localization of a lost brachytherapy seed.

    abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595528

    authors: Woolfenden JM,Barber HB,Oleson JR,Wild WJ

    更新日期:1984-07-01 00:00:00

  • Practical reconstruction protocol for quantitative (90)Y bremsstrahlung SPECT/CT.

    abstract:PURPOSE:To develop a practical background compensation (BC) technique to improve quantitative (90)Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. METHODS:All images were acquired using medium-energy collimation in six energy wi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4960629

    authors: Siman W,Mikell JK,Kappadath SC

    更新日期:2016-09-01 00:00:00

  • Computed tomography scanning with simultaneous patient translation.

    abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596464

    authors: Crawford CR,King KF

    更新日期:1990-11-01 00:00:00

  • Ultrasound contrast-detail analysis: a preliminary study in human observer performance.

    abstract::Results of a human observer performance study using a new ultrasound contrast-detail (CD) phantom are reported. The new phantom allows estimates of the fundamental statistical uncertainties involved in CD analysis. Results of these experiments show that observers generally considered to be "trained" require experience...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597147

    authors: Hall TJ,Insana MF,Soller NM,Harrison LA

    更新日期:1993-01-01 00:00:00

  • JADA: a graphical user interface for comprehensive internal dose assessment in nuclear medicine.

    abstract:PURPOSE:The main objective of this work was to design a comprehensive dosimetry package that would keep all aspects of internal dose calculation within the framework of a single software environment and that would be applicable for a variety of dose calculation approaches. METHODS:Our MATLAB-based graphical user inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810963

    authors: Grimes J,Uribe C,Celler A

    更新日期:2013-07-01 00:00:00

  • A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy.

    abstract::The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312190

    authors: Arnfield MR,Siebers JV,Kim JO,Wu Q,Keall PJ,Mohan R

    更新日期:2000-10-01 00:00:00

  • Mapping structural changes in breast tissue disease using x-ray scattering.

    abstract::Spread of invasive carcinoma throughout breast tissue is believed to occur at supramolecular levels, beyond the range of standard histopathology identification. Small angle x-ray scattering (SAXS) is capable of characterizing the structural properties of collagen and tissue found in the breast at the scale of tens to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3147144

    authors: Sidhu S,Siu KK,Falzon G,Hart SA,Foxe JG,Lewis RA

    更新日期:2009-07-01 00:00:00

  • Three-dimensional ultrasound system for guided breast brachytherapy.

    abstract::Breast-conserving surgery combined with subsequent radiation therapy is a standard procedure in breast cancer treatment. The disadvantage of whole-breast beam irradiation is that it requires 20-25 treatment days, which is inconvenient for patients with limited mobility or who reside far from the treatment center. Howe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3243865

    authors: De Jean P,Beaulieu L,Fenster A

    更新日期:2009-11-01 00:00:00

  • Limitations of two-dimensional treatment planning programs.

    abstract::Some limitations of conventional two-dimensional computer programs used to plan radiation therapy are presented. These include: a lack of involvement in defining the clinical problem; deficiencies in the algorithms for computing dose; failure to compute dose throughout the volume of interest; an inability to handle tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595226

    authors: Goitein M

    更新日期:1982-07-01 00:00:00

  • COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs.

    abstract::Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103Pd, 125I, and 131Cs radionuclides, respectively, were modeled and benchmarked against previously published ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2940604

    authors: Melhus CS,Rivard MJ

    更新日期:2008-07-01 00:00:00

  • Characterizing the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations.

    abstract:PURPOSE:To characterize the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations. To assess the spatial resolution of proton/carbon radiographic imaging. METHODS:A phantom was specifically modeled with inserts composed of two materials with three different densities of bone and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4819816

    authors: Seco J,Oumano M,Depauw N,Dias MF,Teixeira RP,Spadea MF

    更新日期:2013-09-01 00:00:00

  • Poster - Thur Eve - 23: Statistical analysis and verification of the percentage depth dose calculation based on the tissue maximum ratio in external beam radiotherapy.

    abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740131

    authors: Isa M,Iqbal K,Afzal M,Buzdar S,Chow J

    更新日期:2012-07-01 00:00:00

  • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.

    abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3177312

    authors: Van Holen R,Staelens S,Vandenberghe S

    更新日期:2009-09-01 00:00:00

  • Continuous time-dependence in computed tomography.

    abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594458

    authors: Holden JE,Ip WR

    更新日期:1978-11-01 00:00:00

  • MO-C-BRCD-03: The Role of Informatics in Medical Physics and Vice Versa.

    abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735777

    authors: Andriole K

    更新日期:2012-06-01 00:00:00

  • Scan pattern optimization for uniform proton beam scanning.

    abstract::Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3158731

    authors: Anferov VA

    更新日期:2009-08-01 00:00:00

  • An algorithm for fast beam angle selection in intensity modulated radiotherapy.

    abstract:PURPOSE:This article aims to introduce a novel algorithm for fast beam angle selection in intensity modulated radiotherapy (IMRT). METHODS:The algorithm models the optimization problem as a beam angle ranking problem and chooses suitable beam angles according to their rank. A new parameter called "beam intensity profi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3517866

    authors: Vaitheeswaran R,Narayanan VK,Bhangle JR,Nirhali A,Kumar N,Basu S,Maiya V

    更新日期:2010-12-01 00:00:00

  • Dosimetric effect of respiration-gated beam on IMRT delivery.

    abstract::Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1592017

    authors: Duan J,Shen S,Fiveash JB,Brezovich IA,Popple RA,Pareek PN

    更新日期:2003-08-01 00:00:00

  • Evaluation of carbon nanotube x-ray source array for stationary head computed tomography.

    abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14696

    authors: Spronk D,Luo Y,Inscoe CR,Lee YZ,Lu J,Zhou O

    更新日期:2020-12-31 00:00:00

  • Monte Carlo dose calculations for a new ovoid shield system for carcinoma of the uterine cervix.

    abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598459

    authors: Weeks KJ

    更新日期:1998-12-01 00:00:00

  • Experimental study of humidity effect on charge measurement of reference ionization chambers in clinical high-energy photon beams.

    abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13665

    authors: Sato Y,Shimizu M,Morishita Y,Sato M,Hoshina M

    更新日期:2019-09-01 00:00:00

  • Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

    abstract:PURPOSE:Dual-energy computed tomography and dual-energy cone-beam computed tomography (DE-CBCT) are promising modalities for applications ranging from vascular to breast, renal, hepatic, and musculoskeletal imaging. Accordingly, the optimization of imaging techniques for such applications would benefit significantly fr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736420

    authors: Gang GJ,Zbijewski W,Webster Stayman J,Siewerdsen JH

    更新日期:2012-08-01 00:00:00

  • A quality assurance program for monitor unit calculators.

    abstract::A quality assurance protocol has been developed to assess the relative accuracy of computerized monitor unit calculations. Results from this testing reveal that errors (defined as the difference between the computer results and those obtained using a standard formula with manual calculation) in monitor unit calculator...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596539

    authors: Dahl RA,McCullough EC,Mellenberg DE

    更新日期:1990-01-01 00:00:00

  • On the effective point of measurement in megavoltage photon beams.

    abstract::This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the cham...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2201147

    authors: Kawrakow I

    更新日期:2006-06-01 00:00:00

  • First study of on-treatment volumetric imaging during respiratory gated VMAT.

    abstract:PURPOSE:To obtain on-treatment volumetric patient anatomy during respiratory gated volumetric modulated arc therapy (VMAT). METHODS:On-board imaging device integrated with Linacs offers a viable tool for obtaining patient anatomy during radiation treatment delivery. In this study, the authors acquired beam-level kV im...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4794925

    authors: Choi K,Xing L,Koong A,Li R

    更新日期:2013-04-01 00:00:00

  • Predicting the noise in hybrid (phase and attenuation) x-ray images acquired with the edge illumination technique.

    abstract:PURPOSE:To analyze the noise performance of the edge illumination phase-based x-ray imaging technique when applying "single-shot" phase retrieval. The latter consists in applying a sample-specific low-pass filter to the raw data, leading to "hybrid" images in which phase and attenuation contrast are merged with each ot...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14366

    authors: Hagen CK,Roche I Morgó O,Olivo A

    更新日期:2020-09-01 00:00:00

  • Optimization of power deposition and a heating strategy for external ultrasound thermal therapy.

    abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406516

    authors: Lin WL,Liang TC,Yen JY,Liu HL,Chen YY

    更新日期:2001-10-01 00:00:00

  • Computerized detection of masses in digital mammograms: automated alignment of breast images and its effect on bilateral-subtraction technique.

    abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597307

    authors: Yin FF,Giger ML,Doi K,Vyborny CJ,Schmidt RA

    更新日期:1994-03-01 00:00:00

  • Dose in the buildup region outside the primary beam.

    abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595508

    authors: Horton JL

    更新日期:1984-05-01 00:00:00