Limitations of two-dimensional treatment planning programs.

Abstract:

:Some limitations of conventional two-dimensional computer programs used to plan radiation therapy are presented. These include: a lack of involvement in defining the clinical problem; deficiencies in the algorithms for computing dose; failure to compute dose throughout the volume of interest; an inability to handle treatments with noncoplanar beams; failure to provide estimates of error; lack of tools for comparing rival plans; inadequate definition of geometric coverage of anatomic structures by external beams; and failure to provide tools for specifying and verifying the accuracy of treatment delivery. Some suggestions are offered for improvements in some of these areas. In particular, subtraction of dose distributions is proposed as a tool for comparing plans, and displays which exhibit the results of error analyses are presented.

journal_name

Med Phys

journal_title

Medical physics

authors

Goitein M

doi

10.1118/1.595226

subject

Has Abstract

pub_date

1982-07-01 00:00:00

pages

580-6

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

9

pub_type

杂志文章
  • A Laplace transform pair model for spectral reconstruction.

    abstract::A four-parameter Laplace transform pair model, which accurately reconstructs an experimental bremsstrahlung spectrum from attenuation data, is presented. Computed spectral values with both aluminum and copper attenuators generally agree with experimental 70-kVp data to better than 2%. Reconstructed spectra at other kV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595193

    authors: Archer BR,Wagner LK

    更新日期:1982-11-01 00:00:00

  • Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

    abstract::Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756941

    authors: Godfrey DJ,Ren L,Yan H,Wu Q,Yoo S,Oldham M,Yin FF

    更新日期:2007-08-01 00:00:00

  • Reliability of water proton chemical shift temperature calibration for focused ultrasound ablation therapy.

    abstract::Our purpose in this work was to assess the reliability of the calibration coefficient for magnetic resonance water proton chemical shift temperature mapping. Over a six month period, the calibration coefficient was measured 15 times in several different phantoms. A highly linear relationship between water proton chemi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598864

    authors: Wu T,Kendell KR,Felmlee JP,Lewis BD,Ehman RL

    更新日期:2000-01-01 00:00:00

  • A novel total variation based ring artifact suppression method for CBCT imaging with two-dimensional antiscatter grids.

    abstract:PURPOSE:Two-dimensional antiscatter grids (2DASG) for cone beam computed tomography (CBCT) is a new area of research to reduce scatter intensity, and consequently improve CBCT image quality. One of the challenges in implementation of 2DASGs is their septa shadows that are impinged on the projections. If these artifacts...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13456

    authors: Alexeev T,Kavanagh B,Miften M,Altunbas C

    更新日期:2019-05-01 00:00:00

  • Technical and dosimetric realization of in vivo x-ray microbeam irradiations at the Munich Compact Light Source.

    abstract:PURPOSE:X-ray microbeam radiation therapy is a preclinical concept for tumor treatment promising tissue sparing and enhanced tumor control. With its spatially separated, periodic micrometer-sized pattern, this method requires a high dose rate and a collimated beam typically available at large synchrotron radiation faci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14433

    authors: Burger K,Urban T,Dombrowsky AC,Dierolf M,Günther B,Bartzsch S,Achterhold K,Combs SE,Schmid TE,Wilkens JJ,Pfeiffer F

    更新日期:2020-10-01 00:00:00

  • Feasibility of estimating regional mechanical properties of cerebral aneurysms in vivo.

    abstract:PURPOSE:In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS:A data assimilation framework was developed to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3355933

    authors: Balocco S,Camara O,Vivas E,Sola T,Guimaraens L,Gratama van Andel HA,Majoie CB,Pozo JM,Bijnens BH,Frangi AF

    更新日期:2010-04-01 00:00:00

  • Using FDG-PET activity as a surrogate for tumor cell density and its effect on equivalent uniform dose calculation.

    abstract::The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imagi...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1779372

    authors: Zhou SM,Wong TZ,Marks LB

    更新日期:2004-09-01 00:00:00

  • Theoretical study of temperature elevation at muscle/bone interface during ultrasound hyperthermia.

    abstract::This paper examines the distributions of the SAR (specific absorption rate) ratio and temperature elevation when an ultrasound beam propagates through the interface of muscle and bone. This interface is regarded as a flat boundary to partition the energy of the ultrasound beam, and the analytical solution of temperatu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598979

    authors: Lin WL,Liauh CT,Chen YY,Liu HC,Shieh MJ

    更新日期:2000-05-01 00:00:00

  • Discriminating solitary cysts from soft tissue lesions in mammography using a pretrained deep convolutional neural network.

    abstract:PURPOSE:It is estimated that 7% of women in the western world will develop palpable breast cysts in their lifetime. Even though cysts have been correlated with risk of developing breast cancer, many of them are benign and do not require follow-up. We develop a method to discriminate benign solitary cysts from malignant...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12110

    authors: Kooi T,van Ginneken B,Karssemeijer N,den Heeten A

    更新日期:2017-03-01 00:00:00

  • Lung morphometry using hyperpolarized 129 Xe multi-b diffusion MRI with compressed sensing in healthy subjects and patients with COPD.

    abstract:PURPOSE:To demonstrate the feasibility of compressed sensing (CS) to accelerate the acquisition of hyperpolarized (HP) 129 Xe multi-b diffusion MRI for quantitative assessments of lung microstructural morphometry. METHODS:Six healthy subjects and six chronic obstructive pulmonary disease (COPD) subjects underwent HP 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12944

    authors: Zhang H,Xie J,Xiao S,Zhao X,Zhang M,Shi L,Wang K,Wu G,Sun X,Ye C,Zhou X

    更新日期:2018-07-01 00:00:00

  • Feasibility of estimating volumetric breast density from mammographic x-ray spectra using a cadmium telluride photon-counting detector.

    abstract:PURPOSE:Mammographic density of glandular breast tissue has a masking effect that can reduce lesion detection accuracy and is also a strong risk factor for breast cancer. Therefore, accurate quantitative estimation of breast density is clinically important. In this study, we investigate experimentally the feasibility o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13031

    authors: Ghammraoui B,Badal A,Glick SJ

    更新日期:2018-06-03 00:00:00

  • Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.

    abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740174

    authors: Jiang R,Fleck A,Schaly B,Charland P,Zhan L,Alliet K,Rachakonda R,Osei E

    更新日期:2012-07-01 00:00:00

  • Analyzing the impact of intrafraction motion: correlation of different dose metrics with changes in target D95%.

    abstract:PURPOSE:A number of techniques are available to determine the dosimetric impact of intrafraction motion during intensity modulated radiation therapy (IMRT). Motion-induced dose perturbations can be determined both computationally and experimentally using a number of different dosimetric metrics. However, these measures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3605633

    authors: Waghorn BJ,Meeks SL,Langen KM

    更新日期:2011-08-01 00:00:00

  • On the capabilities of conventional x-ray tubes to deliver ultra-high (FLASH) dose rates.

    abstract:PURPOSE:By means of Monte Carlo (MC) simulations and indirect measurements, we have evaluated the maximum dose rates achievable with conventional x-ray tubes and related them to FLASH therapy dose rates of >40 Gy/s. METHODS:Monte Carlo models of two 160 kV x-ray tubes, the 3-kW MXR-160/22 and the 6-kW MXR-165, were bu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13858

    authors: Bazalova-Carter M,Esplen N

    更新日期:2019-12-01 00:00:00

  • Accurate assessment and prediction of noise in clinical CT images.

    abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938588

    authors: Tian X,Samei E

    更新日期:2016-01-01 00:00:00

  • A method for reducing motion induced errors in T2-weighted magnetic resonance imaging.

    abstract::It is known that motion of an object imaged by magnetic resonance imaging leads to errors and artifacts in the image. This effect is especially important when a pulse sequence with long echo time (TE) and long TR is used to provide T2-weighted images. We have modified the usual spin warp imaging pulse sequence in a wa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596026

    authors: Joseph PM,Shetty A,Bonaroti EA

    更新日期:1987-07-01 00:00:00

  • SU-E-T-619: A Network-Flow Solution Approach to VMAT Treatment Plan Optimization.

    abstract:PURPOSE:To add mathematical rigor to the merging phase of the recently published two-stage VMAT optimization method called VMERGE. Using an exact merging method, we are able to better characterize the tradeoff between delivery efficiency and dose quality. METHODS:VMERGE begins with an IMRT plan that uses 180 equi-spac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735709

    authors: Salari E,Craft D

    更新日期:2012-06-01 00:00:00

  • A limited-angle intrafraction verification (LIVE) system for radiation therapy.

    abstract:PURPOSE:Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4861820

    authors: Ren L,Zhang Y,Yin FF

    更新日期:2014-02-01 00:00:00

  • Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming.

    abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881096

    authors: Maduskar P,Hogeweg L,de Jong PA,Peters-Bax L,Dawson R,Ayles H,Sánchez CI,van Ginneken B

    更新日期:2014-07-01 00:00:00

  • An optimization algorithm for 3D real-time lung tumor tracking during arc therapy using kV projection images.

    abstract:PURPOSE:To develop a real-time markerless 3D tumor tracking using kilovoltage (kV) cone-beam CT (CBCT) projection images during volumetric modulated arc therapy (VMAT) treatment of lung tumors. METHODS:The authors have developed a method to identify the position of lung tumors during VMAT treatment, where the current ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4821545

    authors: Zhuang L,Liang J,Yan D,Zhang T,Marina O,Ionascu D

    更新日期:2013-10-01 00:00:00

  • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams.

    abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598293

    authors: Pasma KL,Heijmen BJ,Kroonwijk M,Visser AG

    更新日期:1998-06-01 00:00:00

  • A general algorithm for calculation of recombination losses in ionization chambers exposed to ion beams.

    abstract:PURPOSE:Dosimetry with ionization chambers in clinical ion beams for radiation therapy requires correction for recombination effects. However, common radiation protocols discriminate between initial and general recombination and provide no universal correction method for the presence of both recombination types in ion ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962483

    authors: Christensen JB,Tölli H,Bassler N

    更新日期:2016-10-01 00:00:00

  • Improved dynamic-programming-based algorithms for segmentation of masses in mammograms.

    abstract::In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2791034

    authors: Rojas Domínguez A,Nandi AK

    更新日期:2007-11-01 00:00:00

  • Fast cross-projection algorithm for reconstruction of seeds in prostate brachytherapy.

    abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1489044

    authors: Narayanan S,Cho PS,Marks RJ 2nd

    更新日期:2002-07-01 00:00:00

  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • Automated segmentation of lungs with severe interstitial lung disease in CT.

    abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3222872

    authors: Wang J,Li F,Li Q

    更新日期:2009-10-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • A statistical approach to infer the minimum setup distance of a well chamber to the wall or to the floor for 192Ir HDR calibration.

    abstract::We propose a new method based on statistical analysis technique to determine the minimum setup distance of a well chamber used in the calibration of 192Ir high dose rate (HDR). The chamber should be placed at least this distance away from any wall or from the floor in order to mitigate the effect of scatter. Three dif...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2911156

    authors: Chang L,Ho SY,Chui CS,Lee JH,Du YC,Chen T

    更新日期:2008-06-01 00:00:00

  • The effect of pitch in multislice spiral/helical CT.

    abstract::The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the de...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598804

    authors: Wang G,Vannier MW

    更新日期:1999-12-01 00:00:00

  • Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy.

    abstract::Radiation sensitive gels have been used as dosimeters for clinical dose verification of different radiation therapy modalities. However, the use of gels is not widespread, because careful techniques are required to achieve the dose precision and accuracy aimed for in clinical dose verification. Here, the introduction ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2712042

    authors: Crescenti RA,Scheib SG,Schneider U,Gianolini S

    更新日期:2007-04-01 00:00:00