Abstract:
:Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40 degrees and acquisition times of less than 10 s. The resulting DTS slices show soft tissue contrast approaching that of full cone-beam CT. External beam radiotherapy target localization using DTS requires the registration of on-board DTS images with corresponding reference image data. This study evaluates three types of reference volume: original reference CT, exact reference DTS (RDTS), and a more computationally efficient approximate reference DTS (RDTSapprox), as well as three different DTS scan angles (22 degrees, 44 degrees, and 65 degrees) for the DTS target localization task. Three-dimensional mutual information (MI) shared between reference and onboard DTS volumes was computed in a region surrounding the spine of a chest phantom, as translations spanning +/-5 mm and rotations spanning +/-5 degrees were simulated along each dimension in the reference volumes. The locations of the MI maxima were used as surrogates for registration accuracy, and the width of the MI peaks were used to characterize the registration robustness. The results show that conventional treatment planning CT volumes are inadequate reference volumes for direct registration with on-board DTS data. The efficient RDTSapprox method also appears insufficient for MI-based registration without further refinement of the technique, though it may be suitable for manual registration performed by a human observer. The exact RDTS volumes, on the other hand, delivered a 3D DTS localization accuracy of 0.5 mm and 0.50 along each axis, using only a single 44 degrees coronal on-board DTS scan of the chest phantom.
journal_name
Med Physjournal_title
Medical physicsauthors
Godfrey DJ,Ren L,Yan H,Wu Q,Yoo S,Oldham M,Yin FFdoi
10.1118/1.2756941subject
Has Abstractpub_date
2007-08-01 00:00:00pages
3374-84issue
8eissn
0094-2405issn
2473-4209journal_volume
34pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4966027
更新日期:2016-12-01 00:00:00
abstract::Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2912178
更新日期:2008-06-01 00:00:00
abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1630492
更新日期:2004-01-01 00:00:00
abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965910
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:Colon cancer is a major public health problem due to its high disease rate and death toll worldwide. The use of FTIR microscopy in the field of cancer diagnosis has become attractive over the past 20 years. In the present study, the authors investigated the potential of FTIR microscopy to define spectral change...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3298013
更新日期:2010-03-01 00:00:00
abstract:PURPOSE:As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modula...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903292
更新日期:2015-01-01 00:00:00
abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1414008
更新日期:2001-11-01 00:00:00
abstract::(Received 22 October 2001; accepted for publication 26 March 2002; published 22 May 2002) With advanced conformal radiotherapy using intensity modulated beams, it is important to have radiation dose verification measurements prior to treatment. Metal oxide semiconductor field effect transistors (MOSFET) have the advan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1481520
更新日期:2002-06-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598953
更新日期:2000-05-01 00:00:00
abstract::Heat therapies such as hyperthermia and thermoablation are very promising approaches in the treatment of cancer. Compared with available hyperthermia modalities, magnetic fluid hyperthermia (MFH) yields better results in uniform heating of the deeply situated tumors. In this approach, fluid consisting of superparamagn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3106343
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:In previous work, the authors developed and demonstrated the concept of an image reconstruction procedure aimed to unify gated and dynamic nuclear cardiac imaging, which the authors have termed five-dimensional (5D) SPECT. Gated imaging permits the clinician to evaluate wall motion and, through the use of stres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3481507
更新日期:2010-09-01 00:00:00
abstract::We have studied the effect of real-time optical image processing (OIP) in an image intensifier/television (II-TV) radiographic imaging system by using a liquid-crystal display (LCD) placed between the II and the TV camera. The LCD compresses the dynamic range of the transmitted image by modulating the spatial distribu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596199
更新日期:1988-11-01 00:00:00
abstract::A fully automatic radiophotoluminescent glass rod dosimeter (GRD) system has recently become commercially available. This article discusses the dosimetric properties of the GRD including uniformity and reproducibility of signal, dose linearity, and energy and directional dependence in high-energy photon beams. In addi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1758351
更新日期:2004-07-01 00:00:00
abstract::Conventional chest radiography is limited by the presence of scattered radiation and the small useful exposure range of radiographic film. A computer-assisted scanning system to minimize these two effects is outlined. The system uses a small beam of radiation swept over the patient's chest in a raster pattern to expos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595327
更新日期:1983-09-01 00:00:00
abstract::Effects of changes in the physics of EGSnrc compared to EGS4/PRESTA on energy deposition kernels for monoenergetic photons and on dose point kernels for beta sources in water are investigated. In the diagnostic energy range, Compton binding corrections were found to increase the primary energy fraction up to 4.5% at 3...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1861412
更新日期:2005-03-01 00:00:00
abstract::This paper describes a multileaf collimator, designed to obtain irregularly shaped neutron fields, that fits into an existing fixed field-size collimator system. The shape of the desired portal field is obtained by appropriately setting the position of each leaf of the collimator. The collimator consists of 40 polyeth...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596084
更新日期:1987-03-01 00:00:00
abstract::We investigated the utility of three manual planimetric methods to quantify carotid plaque volume. A single observer measured 15 individual plaques from 15 three-dimensional (3D) ultrasound (3D US) images of patients ten times each using three different planimetric approaches. Individual plaque volumes were measured (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2715487
更新日期:2007-04-01 00:00:00
abstract:PURPOSE:The aiming is getting accurate liver contour structures automatically for following adaptive radiation therapy in daily CBCT images which is very low-contrast comparing the planning CT. METHODS:Probabilistic atlas is constructed by 50 intravenous contrast planning CT images by iterative affine registration pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734730
更新日期:2012-06-01 00:00:00
abstract::Because of the high energy of the treatment beam, contrast of portal verification films is very poor. A simple contrast enhancement technique is described which we have labeled selective histogram equalization (SHE), to improve visualization of double-exposure portal images and this facilitate the beam verification pr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597085
更新日期:1993-01-01 00:00:00
abstract::The line spread function (LSF) of an imaging system incorporating a pinhole of 0.275 cm radius and a scintillation camera has been measured and its full width at half maximum (FWHM) compared to the values predicted by an expression based on the resolution index of Anger. In most cases, the actual resolution of the sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594755
更新日期:1980-09-01 00:00:00
abstract::A study of the objective imaging characteristics of a new asymmetric screen-film system is presented herein. The system is characterized by high x-ray absorption asymmetric screens, and a low-noise, high-contrast asymmetric film having near-zero crossover. Comparisons are made with the imaging characteristics of two w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597407
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:A major challenge of four dimensional computed tomography (4DCT) in treatment planning and delivery has been the lack of respiration amplitude and phase reproducibility during image acquisition. The implementation of a prospective gating algorithm would ensure that images would be acquired only during user-spec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3556589
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14400
更新日期:2020-10-01 00:00:00
abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2964092
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12285
更新日期:2017-09-01 00:00:00
abstract::The Radiological Physics Center (RPC) developed two heterogeneous anthropomorphic quality assurance phantoms for use in verifying the accuracy of radiation delivery: one for intensity-modulated radiation therapy (IMRT) to the pelvis and the other for stereotactic body radiation therapy (SBRT) to the thorax. The purpos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2737158
更新日期:2007-06-01 00:00:00
abstract::By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design per...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2357020
更新日期:2006-11-01 00:00:00
abstract:PURPOSE:To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS:A PET-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4867856
更新日期:2014-04-01 00:00:00
abstract::This paper examines the distributions of the SAR (specific absorption rate) ratio and temperature elevation when an ultrasound beam propagates through the interface of muscle and bone. This interface is regarded as a flat boundary to partition the energy of the ultrasound beam, and the analytical solution of temperatu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598979
更新日期:2000-05-01 00:00:00