Abstract:
:Conventional chest radiography is limited by the presence of scattered radiation and the small useful exposure range of radiographic film. A computer-assisted scanning system to minimize these two effects is outlined. The system uses a small beam of radiation swept over the patient's chest in a raster pattern to expose a conventional film cassette, while a slit collimator scanning between the patient and the film serves to reject scattered photons. A microcomputer measures beam attenuation by the patient with a detector placed behind the film which in turn automatically adjusts the x-ray tube output to minimize excursions in film exposure as the beam scans. A formalism which relates the patient transmission and film exposure distribution is developed and a system transfer function is given. It is shown that such a system operates as a spatial filter which attenuates film contrast for structures of spatial frequency less than the inverse scanning beam width. By manipulating the software parameters of the feedback network, it is possible to alter this filter and produce radiographs with low spatial frequency enhancement, attenuation, or contrast inversion.
journal_name
Med Physjournal_title
Medical physicsauthors
Plewes DBdoi
10.1118/1.595327subject
Has Abstractpub_date
1983-09-01 00:00:00pages
646-54issue
5eissn
0094-2405issn
2473-4209journal_volume
10pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734756
更新日期:2012-06-01 00:00:00
abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1751251
更新日期:2004-06-01 00:00:00
abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868780
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:The recent development of multifocal stereotactic radiosurgery (SRS) using a single isocenter volumetric modulated arc theory (VMAT) technique warrants a re-examination of the quality assurance (QA) tolerances for routine mechanical QA recommended by the American Association of Physicists in Medicine Task Group...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4962471
更新日期:2016-10-01 00:00:00
abstract:PURPOSE:Within the European project ALLEGRO (grant agreement no. 231965), the out-of-field dose delivered to a patient when treated with different radiotherapy modalities was investigated. The study compared the dose distribution during photon and particle irradiations both in a water and an anthropomorphic phantom to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735792
更新日期:2012-06-01 00:00:00
abstract::Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1376176
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To develop a pencil beam dose calculation algorithm for scanned proton beams that improves modeling of scatter events. METHODS:Our pencil beam algorithm (PBA) was developed for calculating dose from monoenergetic, parallel proton beams in homogeneous media. Fermi-Eyges theory was implemented for pencil beam tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735624
更新日期:2012-06-01 00:00:00
abstract::The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawbac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508110
更新日期:2002-10-01 00:00:00
abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4816656
更新日期:2013-09-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597412
更新日期:1994-10-01 00:00:00
abstract::The purpose of this study is to perform a clinical evaluation of the first commercial (MDS Nordion, now Nucletron) treatment planning system for electron beams incorporating Monte Carlo dose calculation module. This software implements Kawrakow's VMC++ voxel-based Monte Carlo calculation algorithm. The accuracy of the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1633105
更新日期:2004-01-01 00:00:00
abstract::Errors in the determination of xenon concentrations in arterial blood during inhalation of xenon-oxygen mixtures are used to assess errors in the derivation of regional cerebral blood flow by the xenon-enhanced computed tomography (CT) method. The results of this study indicate that approximating the arterial buildup ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596051
更新日期:1987-05-01 00:00:00
abstract::Double checking of the monitor units (MU) is an important step in the quality assurance (QA) process in radiosurgery. In this paper we propose the use of an independent algorithm constructed using the ellipsoid which best fits the measurements taken with the bubble head frame. The monitor units calculated by this inde...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2815361
更新日期:2008-01-01 00:00:00
abstract::Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are pre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198168
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:One limitation of positron emission tomography (PET) imaging of the torso is patient motion. Motion-compensated image reconstruction (MCIR) is one method employed to reduce the deleterious effects of motion. Existing MCIR algorithms use a single sensitivity correction term, which provides inexact normalization ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3611041
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3641874
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:The variable resolution x-ray (VRX) CT scanner provides substantial improvement in the spatial resolution by matching the scanner's field of view (FOV) to the size of the object being imaged. Intercell x-ray cross-talk is one of the most important factors limiting the spatial resolution of the VRX detector. In ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3555035
更新日期:2011-03-01 00:00:00
abstract::Receiver operating characteristic (ROC) methodology is widely used in evaluating medical imaging modalities. While appropriate in some cases, it has several drawbacks when the detection task, e.g., nodule detection, involves localizing the abnormality. Free-response receiver operating characteristic (FROC) methodology...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596358
更新日期:1989-07-01 00:00:00
abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4876379
更新日期:2014-06-01 00:00:00
abstract:PURPOSE:Results about the feasibility of a method for quasi real time in vivo dosimetry (IVD) at the isocenter point for volumetric modulated arc therapy (VMAT) are here reported. The method is based on correlations between the EPID signal and the dose on the beam central axis. Moreover, the γ-analysis of EPID images w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4875685
更新日期:2014-06-01 00:00:00
abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594276
更新日期:1976-03-01 00:00:00
abstract:PURPOSE:Bilateral filters have been substantially exploited in numerous magnetic resonance (MR) image restoration applications for decades. Due to the deficiency of theoretical basis on the filter parameter setting, empirical manipulation with fixed values and noise variance-related adjustments has generally been emplo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12157
更新日期:2017-04-01 00:00:00
abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12759
更新日期:2018-03-01 00:00:00
abstract::Fluoroscopy is a low dose imaging technique. As such, a very sensitive detector is required to create images of good quality. Present day flat panel active matrix read out systems introduce an amount of noise that inhibits present direct and indirect methods from producing optimal quality images at fluoroscopic exposu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1513157
更新日期:2002-11-01 00:00:00
abstract::In order to understand the role of water desorption, i.e., the opposite of water adsorption, in optical clearing of biological tissue created by the application of hyperosmotic agents, dynamics of water loss in fresh porcine muscle tissue administrated with glycerol or ethylene glycol was investigated with the near-in...
journal_title:Medical physics
pub_type:
doi:10.1118/1.1576228
更新日期:2003-06-01 00:00:00
abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3168554
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can ap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3244035
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4908000
更新日期:2015-04-01 00:00:00
abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1564091
更新日期:2003-05-01 00:00:00
abstract::The effective energy of the x-ray beam from linear accelerators changes as a function of the position in the beam due to nonuniform filtration by the flattening filter. In this work, the transmittance through a water column was measured in good geometry and the beam quality characterized in units of HVL in water. Meas...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594677
更新日期:1980-03-01 00:00:00