Abstract:
:An overall practical dosimetric study of a 10-MV photon beam produced by a Varian Clinac-18 linear accelerator is presented. In particular measurements were made to provide data which could be utilized in computerized dosage calculations using the concept of dividing the radiation beam into primary and scatter components. From the measured percentage depth doses, tissue-phantom ratios are calculated. Special consideration is given to the derivation and mesurement of zero-area tissue-phantom ratios such that scatter-phantom ratios could be obtained. The computer techniques were tested under a number of specified conditions by comparing the calculated results to the measured data. The variation of dose with field size and distance is considered and attenuation data for shielding, wedge and compensating materials is provided.
journal_name
Med Physjournal_title
Medical physicsauthors
Van Dyk Jdoi
10.1118/1.594311subject
Has Abstractpub_date
1977-03-01 00:00:00pages
145-53issue
2eissn
0094-2405issn
2473-4209journal_volume
4pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quali...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735679
更新日期:2012-06-01 00:00:00
abstract::New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with 192Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3013574
更新日期:2008-12-01 00:00:00
abstract::Recent working groups of the AAPM [Almond et al., Med. Phys. 26, 1847 (1999)] and the IAEA (Andreo et al., Draft V.7 of "An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water," IAEA, 2000) have described guidelines to base reference dosimetry of high energy photon beams on absorb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1328081
更新日期:2000-12-01 00:00:00
abstract::A simple noninvasive method is described for determining the backscatter to a monitor chamber of a medical accelerator based on the measurement of charge deposited in the target. This method is compared quantitatively to the more elaborate telescopic method for photon beams of 6 MV and 15 MV on linear accelerators hav...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598203
更新日期:1998-03-01 00:00:00
abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868693
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14348
更新日期:2020-09-01 00:00:00
abstract::Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 degrees MCD and 180 degrees MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1487861
更新日期:2002-07-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:For the purpose of size-specific dose estimation, information regarding patient attenuation is required. The purpose of this work is to describe a method for measuring patient attenuation and expressing the results in terms of a water cylinder, with cross sectional area A(w), which would absorb the same average...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754303
更新日期:2012-11-01 00:00:00
abstract::The polarity effect was investigated for three different commercially available plane-parallel ionization chambers: the Memorial Pipe chamber, the Victoreen/Nuclear Associates model 30-329 chamber manufactured by PTW, Frieburg, and the Capintec PS-033 thin-window ionization chamber. The primary study was the polarity ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596072
更新日期:1987-03-01 00:00:00
abstract:PURPOSE:The authors describe the integration of optical imaging with a targeted small animal irradiator device, focusing on design, instrumentation, 2D to 3D image registration, 2D targeting, and the accuracy of recovering and mapping the optical signal to a 3D surface generated from the cone-beam computed tomography (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894730
更新日期:2014-10-01 00:00:00
abstract::In previous work it has been shown that a standard backpropagation neural network can be trained to reconstruct sections of single photon emission computed tomography (SPECT) images based on the planar image projections as inputs. In this study, it is demonstrated that an artificial neural network (ANN) trained on a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597586
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:Image guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is prefer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13958
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3397458
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12463
更新日期:2017-10-01 00:00:00
abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2360014
更新日期:2006-11-01 00:00:00
abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3456598
更新日期:2010-07-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract:PURPOSE:There are growing expectations that imaging biomarkers for tumor therapeutic drug response assessment will speed up preclinical testing of anticancer drugs in rodent models. The only imaging biomarker presently approved by the U.S. Food and Drug Administration is tumor size measurement based on either World Hea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3464491
更新日期:2010-09-01 00:00:00
abstract::The data from Meisberger et al. [Radiology 90, 953-957 (1968)] are often used as a basis for dose calculations in brachytherapy. In order to describe the absorbed dose in water around a brachytherapy point source, Meisberger provided a polynomial fit for different isotopes taking into account the effect of attenuation...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597583
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with Ga...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735542
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based te...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4935199
更新日期:2015-12-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract:PURPOSE:Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the hi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4752211
更新日期:2012-10-01 00:00:00
abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597725
更新日期:1996-08-01 00:00:00
abstract:PURPOSE:Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. P...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903889
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:Scattered radiation remains to be a major cause of image quality degradation in Flat Panel Detector (FPD)-based Cone-beam computed tomography (CBCT). We have been investigating a novel two-dimensional antiscatter grid (2D-ASG) concept to reduce scatter intensity, and hence improve CBCT image quality. We present...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12724
更新日期:2018-02-01 00:00:00
abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906129
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734816
更新日期:2012-06-01 00:00:00
abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00