Measurement of backscatter to the monitor chamber of medical accelerators using target charge.

Abstract:

:A simple noninvasive method is described for determining the backscatter to a monitor chamber of a medical accelerator based on the measurement of charge deposited in the target. This method is compared quantitatively to the more elaborate telescopic method for photon beams of 6 MV and 15 MV on linear accelerators having mica and Kapton monitor chambers. The new target charge method gives results consistent with the telescopic method to within 0.3%.

journal_name

Med Phys

journal_title

Medical physics

authors

Lam KL,Muthuswamy MS,Ten Haken RK

doi

10.1118/1.598203

subject

Has Abstract

pub_date

1998-03-01 00:00:00

pages

334-8

issue

3

eissn

0094-2405

issn

2473-4209

journal_volume

25

pub_type

杂志文章
  • Deconvolution techniques for removing the effects of chemical shift in 19F nuclear magnetic resonance imaging of perfluorocarbon compounds.

    abstract::Nuclear magnetic resonance (NMR) imaging of perfluorocarbon (PFC) emulsions and neat liquids has shown potential for in vivo oxygen imaging in blood and organ tissue. PFC compounds exhibit complicated NMR spectra caused by chemical shifts and spin-spin couplings which can lead to artifacts and degraded spatial resolut...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595960

    authors: Busse LJ,Thomas SR,Pratt RG,Clark LC Jr,Ackerman JL,Samaratunga RC,Hoffmann RE

    更新日期:1986-07-01 00:00:00

  • Novel methods of measuring single scan dose profiles and cumulative dose in CT.

    abstract::Computed tomography dose index (CTDI) is a conventional indicator of the patient dose in CT studies. It is measured as the integration of the longitudinal single scan dose profile (SSDP) by using a 100-mm-long pencil ionization chamber and a single axial scan. However, the assumption that most of the SSDP is contained...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1835571

    authors: Nakonechny KD,Fallone BG,Rathee S

    更新日期:2005-01-01 00:00:00

  • Volumetric breast density evaluation from ultrasound tomography images.

    abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2964092

    authors: Glide-Hurst CK,Duric N,Littrup P

    更新日期:2008-09-01 00:00:00

  • Measurement with microscopic MRI and simulation of flow in different aneurysm models.

    abstract:PURPOSE:The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4929758

    authors: Edelhoff D,Walczak L,Frank F,Heil M,Schmitz I,Weichert F,Suter D

    更新日期:2015-10-01 00:00:00

  • A novel 3D printing method for accurate anatomy replication in patient-specific phantoms.

    abstract:PURPOSE:A novel 3D printing method has been developed, which employs human CT images to construct patient specific phantoms by controlling the filament extrusion rate. METHODS:An in-house software was developed comprising pixel-by-pixel (PbP) reading of the Hounsfield Units (HU) values in the original patient DICOM im...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13154

    authors: Okkalidis N

    更新日期:2018-10-01 00:00:00

  • Estimation of the axial wall strains induced by an arterial stenosis at peak flow.

    abstract::In the last 30 years, thousands of basic or clinical studies have been devoted to atherosclerosis or to the problem of restenosis after angioplasty. In these studies, axial stresses in the vessel wall have received practically no attention, contrary to circumferential stress and purely biological aspects. Based on a r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1844432

    authors: Doriot PA,Dorsaz PA

    更新日期:2005-02-01 00:00:00

  • Computed tomography scanning with simultaneous patient translation.

    abstract::This paper deals with methods of reducing the total time required to acquire the projection data for a set of contiguous computed tomography (CT) images. Normally during the acquisition of a set of slices, the patient is held stationary during data collection and translated to the next axial location during an intersc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596464

    authors: Crawford CR,King KF

    更新日期:1990-11-01 00:00:00

  • Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies.

    abstract::We applied Monte Carlo methods for the simulation of x-ray scattering in water phantoms. The phantom thickness was varied from 5 to 20 cm, and the monoenergetic incident x rays were varied from 15 to 100 keV. Eight screen pairs and a total absorption system were used as x-ray receptors. We determined the angular, spec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595771

    authors: Chan HP,Doi K

    更新日期:1985-03-01 00:00:00

  • Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung.

    abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4896101

    authors: Dzyubak O,Kincaid R,Hertanto A,Hu YC,Pham H,Rimner A,Yorke E,Zhang Q,Mageras GS

    更新日期:2014-10-01 00:00:00

  • Design and performance of a compact and stationary microSPECT system.

    abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822621

    authors: Van Holen R,Vandeghinste B,Deprez K,Vandenberghe S

    更新日期:2013-11-01 00:00:00

  • SU-E-T-210: Surviving a Visit by the Radiological Physics Center.

    abstract:PURPOSE:To demonstrate an objective approach to determining if a negative report from the Radiological Physics Center (RPC) of greater than 10% error is valid or has clinical significance. METHODS:The discrepancy involved the clinical activity (mgRaEq) of Cs-137 sources, some manufactured by 3M and some by Amersham. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735271

    authors: Grant W 3rd,Mcgary J,Rosen I,Nitsch P,Davidson S

    更新日期:2012-06-01 00:00:00

  • Two-dimensional antiscatter grid: A novel scatter rejection device for Cone-beam computed tomography.

    abstract:PURPOSE:Scattered radiation remains to be a major cause of image quality degradation in Flat Panel Detector (FPD)-based Cone-beam computed tomography (CBCT). We have been investigating a novel two-dimensional antiscatter grid (2D-ASG) concept to reduce scatter intensity, and hence improve CBCT image quality. We present...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12724

    authors: Alexeev T,Kavanagh B,Miften M,Altunbas C

    更新日期:2018-02-01 00:00:00

  • Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques.

    abstract:PURPOSE:The authors' objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-sp...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892606

    authors: Grimes J,Celler A

    更新日期:2014-09-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • On-board SPECT for localizing functional targets: a simulation study.

    abstract::Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3113902

    authors: Roper J,Bowsher J,Yin FF

    更新日期:2009-05-01 00:00:00

  • Characterization of trabecular bone plate-rod microarchitecture using multirow detector CT and the tensor scale: Algorithms, validation, and applications to pilot human studies.

    abstract:PURPOSE:Osteoporosis is a common bone disease associated with increased risk of low-trauma fractures leading to substantial morbidity, mortality, and financial costs. Clinically, osteoporosis is defined by low bone mineral density (BMD); however, increasing evidence suggests that trabecular bone (TB) microarchitectural...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4928481

    authors: Saha PK,Liu Y,Chen C,Jin D,Letuchy EM,Xu Z,Amelon RE,Burns TL,Torner JC,Levy SM,Calarge CA

    更新日期:2015-09-01 00:00:00

  • Assessing radiation and light field congruence with a video based electronic portal imaging device.

    abstract::Projected light fields are used on treatment simulators and teletherapy treatment units to delineate the size and position of the radiation beam. Any discrepancy between these fields will lead to a systematic field placement error, with possibly serious implications with regard to the accuracy of the delivered dose di...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597867

    authors: Luchka K,Chen D,Shalev S,Gluhchev G,Rajapakshe R

    更新日期:1996-07-01 00:00:00

  • Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model.

    abstract::The widespread application of positron emission tomography (PET) in clinical oncology has driven this imaging technology into a number of new research and clinical arenas. Increasing numbers of patient scans have led to an urgent need for efficient data handling and the development of new image analysis techniques to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2432404

    authors: Montgomery DW,Amira A,Zaidi H

    更新日期:2007-02-01 00:00:00

  • WE-G-211-02: Origins and Development of Magnetic Resonance Imaging.

    abstract::The method of magnetic resonance imaging (MRI) was an extension of nuclear magnetic resonance (NMR) spectroscopy that was enabled by computational systems capable of performing the Fast Fourier Transform. Initially, a diverse group of methods were proposed for producing images with NMR, with the multi-slice spin-warp ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736176

    authors: Clarke G

    更新日期:2012-06-01 00:00:00

  • A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

    abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941954

    authors: Hsieh SS,Chesler DA,Fleischmann D,Pelc NJ

    更新日期:2016-03-01 00:00:00

  • Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy.

    abstract:PURPOSE:Prostate biopsy, performed using two-dimensional (2D) transrectal ultrasound (TRUS) guidance, is the clinical standard for a definitive diagnosis of prostate cancer. Histological analysis of the biopsies can reveal cancerous, noncancerous, or suspicious, possibly precancerous, tissue. During subsequent biopsy s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3298010

    authors: Karnik VV,Fenster A,Bax J,Cool DW,Gardi L,Gyacskov I,Romagnoli C,Ward AD

    更新日期:2010-02-01 00:00:00

  • Directional scatter imaging for the stereoscopic tracking of fiducial markers in a single kV exposure.

    abstract:PURPOSE:To demonstrate, via Monte Carlo simulation, that an image obtained from the patient-generated scattered radiation forced to impinge on the detector from a known direction by means of parallel-focused grids, can be used to complement the information conveyed by the primary image, such that accurate stereoscopic ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12712

    authors: Garnica-Garza HM

    更新日期:2018-02-01 00:00:00

  • X-ray diffraction computed tomography.

    abstract::Coherent scattering of x-ray photons leads to the phenomenon of x-ray diffraction, which is widely used for determining atomic structure in materials science. A technique [x-ray diffraction computed tomography (CT)] is described, analogous to conventional CT, in which the x-ray diffraction properties of a stack of two...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596063

    authors: Harding G,Kosanetzky J,Neitzel U

    更新日期:1987-07-01 00:00:00

  • Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA.

    abstract::The fast imaging method named skipped phase encoding and edge deghosting (SPEED) has been demonstrated to reduce scan time considerably with typical magnetic resonance imaging data. In this work, SPEED is simplified with improved efficiency to accelerate the scan of sparse objects; we refer to this method as S-SPEED. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2750966

    authors: Chang Z,Xiang QS

    更新日期:2007-08-01 00:00:00

  • Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).

    abstract:PURPOSE:Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the par...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12855

    authors: Gomez-Cardona D,Hayes JW,Zhang R,Li K,Cruz-Bastida JP,Chen GH

    更新日期:2018-05-01 00:00:00

  • TransitQA - A new method for transit dosimetry of Tomotherapy patients.

    abstract:PURPOSE:TransitQA is an innovative method for Tomotherapy transit dosimetry using the on-board detector (OBD). Our previously published model for Tomotherapy treatment plan verification (AirQA) has been enhanced to take into account patient and couch transmission. AirQA estimates the OBD signal during irradiation with ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12672

    authors: Pisaturo O,Miéville F,Tercier PA,Allal AS

    更新日期:2018-01-01 00:00:00

  • The optimization of signal detectability in digital fluoroscopy.

    abstract::An optimization analysis of digital fluoroscopy has been carried out using (signal/noise)2/dose as a figure of merit. Three signal detection tasks have been considered: (i) small iodine-containing blood vessels; (ii) regions of fat; and (iii) microcalcifications. The effects of x-ray beam filtration and kilovoltage on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595130

    authors: Zamenhof RG

    更新日期:1982-09-01 00:00:00

  • A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

    abstract:PURPOSE:To introduce a pair of accelerated non-Cartesian acquisition principles that when combined, exploit the periodicity of k-space acquisition, and thereby enable acquisition of high-temporal cine Cardiac Magnetic Resonance (CMR). METHODS:The mathematical formulation of a noniterative, undersampled non-Cartesian c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12234

    authors: Kawaji K,Patel MB,Cantrell CG,Tanaka A,Marino M,Tamura S,Wang H,Wang Y,Carroll TJ,Ota T,Patel AR

    更新日期:2017-07-01 00:00:00

  • A field-shaping multi-well avalanche detector for direct conversion amorphous selenium.

    abstract:PURPOSE:A practical detector structure is proposed to achieve stable avalanche multiplication gain in direct-conversion amorphous selenium radiation detectors. METHODS:The detector structure is referred to as a field-shaping multi-well avalanche detector. Stable avalanche multiplication gain is achieved by eliminating...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.4769110

    authors: Goldan AH,Zhao W

    更新日期:2013-01-01 00:00:00

  • Verification of treatment parameter transfer by means of electronic portal dosimetry.

    abstract::Electronic portal imaging devices (EPIDs) are mainly used for patient setup verification during treatment but other geometric properties like block shape and leaf positions are also determined. Electronic portal dosimetry allows dosimetric treatment verification. By combining geometric and dosimetric information, the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1640972

    authors: Nijsten SM,Minken AW,Lambin P,Bruinvis IA

    更新日期:2004-02-01 00:00:00