Abstract:
PURPOSE:Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based technique to compute full three-dimensional patient dose reconstructed from on-treatment EPID portal images (i.e., transmission images). METHODS:EPID dose is converted to incident fluence entering the patient using a series of steps which include converting measured EPID dose to fluence at the detector plane and then back-projecting the primary source component of the EPID fluence upstream of the patient. Incident fluence is then recombined with predicted extra-focal fluence and used to calculate 3D patient dose via a collapsed-cone convolution method. This method is implemented in an iterative manner, although in practice it provides accurate results in a single iteration. The robustness of the dose reconstruction technique is demonstrated with several simple slab phantom and nine anthropomorphic phantom cases. Prostate, head and neck, and lung treatments are all included as well as a range of delivery techniques including VMAT and dynamic intensity modulated radiation therapy (IMRT). RESULTS:Results indicate that the patient dose reconstruction algorithm compares well with treatment planning system computed doses for controlled test situations. For simple phantom and square field tests, agreement was excellent with a 2%/2 mm 3D chi pass rate ≥98.9%. On anthropomorphic phantoms, the 2%/2 mm 3D chi pass rates ranged from 79.9% to 99.9% in the planning target volume (PTV) region and 96.5% to 100% in the low dose region (>20% of prescription, excluding PTV and skin build-up region). CONCLUSIONS:An algorithm to reconstruct delivered patient 3D doses from EPID exit dosimetry measurements was presented. The method was applied to phantom and patient data sets, as well as for dynamic IMRT and VMAT delivery techniques. Results indicate that the EPID dose reconstruction algorithm presented in this work is suitable for clinical implementation.
journal_name
Med Physjournal_title
Medical physicsauthors
Van Uytven E,Van Beek T,McCowan PM,Chytyk-Praznik K,Greer PB,McCurdy BMdoi
10.1118/1.4935199subject
Has Abstractpub_date
2015-12-01 00:00:00pages
6945-54issue
12eissn
0094-2405issn
2473-4209journal_volume
42pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Nuclear Magnetic Resonance (NMR) permits the noninvasive measurement of blood flow signals unimpaired by clothes, bandages, casts, etc. The cylindrical crossed-coil NMR blood flowmeter was used to measure blood flow through a cross-section of the human forearm. Two calibration procedures are described: one for pulsati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594989
更新日期:1981-07-01 00:00:00
abstract:PURPOSE:There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3475942
更新日期:2010-09-01 00:00:00
abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1809991
更新日期:2004-11-01 00:00:00
abstract:PURPOSE:Quantitative cone-beam CT (CBCT) imaging is on increasing demand for high-performance image guided radiation therapy (IGRT). However, the current CBCT has poor image qualities mainly due to scatter contamination. Its current clinical application is therefore limited to patient setup based on only bony structure...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3693050
更新日期:2012-04-01 00:00:00
abstract::In this paper, two new boundary tracing algorithms for segmentation of breast masses are presented. These new algorithms are based on the dynamic programming-based boundary tracing (DPBT) algorithm proposed in Timp and Karssemeijer, [S. Timp and N. Karssemeijer, Med. Phys. 31, 958-971 (2004)] The DPBT algorithm contai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2791034
更新日期:2007-11-01 00:00:00
abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2719363
更新日期:2007-05-01 00:00:00
abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965985
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4931964
更新日期:2015-11-01 00:00:00
abstract::Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598916
更新日期:2000-03-01 00:00:00
abstract::We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596402
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:Examine the use of TomoDose for Tomotherapy quality assurance. METHODS:Baseline TomoDose profiles are acquired annually in accordance with TG-148. During monthly quality assurance, TomoDose is irradiated with a static beam and referenced to baseline. Differences between superimposed profiles are evaluated mont...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735202
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4801902
更新日期:2013-05-01 00:00:00
abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2360014
更新日期:2006-11-01 00:00:00
abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965976
更新日期:2008-07-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12271
更新日期:2017-07-01 00:00:00
abstract::The commonly used Blunck and Leisegang electron energy-loss distribution falls off too rapidly with increasing energy loss. Also, for large thicknesses and/or low-Z media, where their distribution should approach Landau's, it normalizes to 0.92 rather than 1.0, it overestimates the number of very small energy-loss eve...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595500
更新日期:1984-05-01 00:00:00
abstract::Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2966353
更新日期:2008-09-01 00:00:00
abstract::Direct comparisons of the National Institute of Standards and Technology's (NIST) Ritz 20 kV to 100 kV standard free-air ionization chamber and a portable variable-length free-air ionization chamber designed by the University of Wisconsin-Madison Accredited Dosimetry Calibration Laboratory (UW-ADCL) were made on NISTs...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598148
更新日期:1997-08-01 00:00:00
abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2937652
更新日期:2008-07-01 00:00:00
abstract::The scattered-photon part of pencil-beam dose kernels for high-energy x-ray beams can be derived experimentally by differentiating the broad-beam scatter-to-primary dose ratio as a function of radius. Formally, this requires a uniform and parallel beam, and the procedure is complicated by the nonideal, actual beam con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597884
更新日期:1996-09-01 00:00:00
abstract::Ultrasound-induced blood stasis has been observed for more than 30 years. Most of the literature has been focused on the health risks associated with this phenomenon and methods employed to prevent stasis from occurring during ultrasound imaging. To date, experimental observations have been either in vitro or invasive...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198196
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12939
更新日期:2018-07-01 00:00:00
abstract::Head-scatter factors of symmetric square and rectangular fields (field center on the central beam axis) defined by the upper (Y) and lower (X) jaws for 6 and 15 MV photon beams from 2300CD and 600C accelerators (Varian Associates, Inc., Palo Alto, CA) were measured, as well as those for fields shaped by the Y jaws and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597617
更新日期:1995-08-01 00:00:00
abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735470
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13163
更新日期:2018-10-01 00:00:00
abstract::For radiation dosimetry calculations of radiolabeled monoclonal antibodies, (MAB), pharmacokinetics are critical. Specifically, pharmacokinetic modeling is a useful component of estimation of cumulated activity in various source organs in the body. It is thus important to formulate general methods of pharmacokinetic m...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.597047
更新日期:1993-03-01 00:00:00
abstract:PURPOSE:The authors are developing a system for calibrated breast density measurements using full field digital mammography (FFDM). Breast tissue equivalent (BTE) phantom images are used to establish baseline (BL) calibration curves at time zero. For a given FFDM unit, the full BL dataset is comprised of approximately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4903299
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:The purpose of this work was to examine the suitability of VIPARnd polymer gel-9.4 T magnetic resonance microimaging system for high spatial resolution dose distribution measurements. METHODS:The VIPARnd samples (3 cm in outside diameter and 12 cm in height) were exposed to ionizing radiation by using a linear...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14186
更新日期:2020-08-01 00:00:00
abstract::We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598389
更新日期:1998-10-01 00:00:00
abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3447726
更新日期:2010-07-01 00:00:00