Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies.

Abstract:

:Two new liquid ionization chamber (LIC) designs, consisting of cylindrical and plane-parallel configurations, are presented. They are designed to be suitable for high-precision measurements of absorbed dose-to-water at dose rates and photon energies typical for LDR intermediate photon energy brachytherapy sources. The chambers have a sensitive liquid layer thickness of 1 mm and sensitive volumes of 7 mm3 (plane-parallel) and 20 mm3 (cylindrical). The liquids used as sensitive media in the chambers are either isooctane (C8H18), tetramethylsilane (Si(CH3)4) or mixtures of these two liquids in the approximate proportions 2 to 1. A chamber filled with such a liquid mixture and with a polarizing voltage of 300 V, provides a volume sensitivity of about 10(-9)C Gy(-1) mm(-3) for absorbed dose measurements in water in an x-ray radiation field with an effective photon energy of 120 keV. In the interval 30 to 140 keV, the relative change in sensitivity is less than +/- 2.5%. The leakage current of the chambers is low and stable, which implies that absorbed dose measurements can be done with good reproducibility at dose-rates as low as 50 microGy min-1 (sigma < 3%). The long-term calibration stability was tested for a set of five chambers over a period of more than 1 year. No systematic change in their sensitivity could be observed. The general recombination at a polarizing voltage of 300 V is less than 2% for dose-rates up to about 100 mGy min-1. The temperature dependence at room temperature is 0.5% per degree C. The response is almost independent of the direction of the radiation for the plane-parallel LIC.

journal_name

Med Phys

journal_title

Medical physics

authors

Wickman G,Johansson B,Bahar-Gogani J,Holmström T,Grindborg JE

doi

10.1118/1.598268

subject

Has Abstract

pub_date

1998-06-01 00:00:00

pages

900-7

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

25

pub_type

杂志文章
  • A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view.

    abstract:PURPOSE:Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3514130

    authors: Li T,Li X,Yang Y,Heron DE,Huq MS

    更新日期:2010-12-01 00:00:00

  • Automated registration of diagnostic to prediagnostic x-ray mammograms: evaluation and comparison to radiologists' accuracy.

    abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3457470

    authors: Pinto Pereira SM,Hipwell JH,McCormack VA,Tanner C,Moss SM,Wilkinson LS,Khoo LA,Pagliari C,Skippage PL,Kliger CJ,Hawkes DJ,Silva IM

    更新日期:2010-09-01 00:00:00

  • Transrectal electrical impedance tomography of the prostate: spatially coregistered pathological findings for prostate cancer detection.

    abstract:PURPOSE:Prostate cancer ranks as one of the most common malignancies and currently represents the second leading cancer-specific cause of death in men. The current use of single modality transrectal ultrasound (TRUS) for biopsy guidance has a limited sensitivity and specificity for accurately identifying cancerous lesi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4803498

    authors: Wan Y,Borsic A,Heaney J,Seigne J,Schned A,Baker M,Wason S,Hartov A,Halter R

    更新日期:2013-06-01 00:00:00

  • A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals.

    abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4926551

    authors: Woerner A,Roeske JC,Harkenrider MM,Fan J,Aydogan B,Koshy M,Laureckas R,Vali F,Campana M,Surucu M

    更新日期:2015-08-01 00:00:00

  • Gradient corrections for reference dosimetry using Farmer-type ionization chambers in single-layer scanned proton fields.

    abstract:PURPOSE:The local depth dose gradient and the displacement correction factor for Farmer-type ionization chambers are quantified for reference dosimetry at shallow depth in single-layer scanned proton fields. METHOD:Integrated radial profiles as a function of depth (IRPDs) measured at three proton therapy centers were ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14554

    authors: Palmans H,Medin J,Trnková P,Vatnitsky S

    更新日期:2020-12-01 00:00:00

  • SU-E-J-192: Static Breath-Hold MRI Based Measurement of Change in Pulmonary Function Following a Course of Radiation Therapy.

    abstract:PURPOSE:Radiation Therapy (RT) induced pulmonary function change may depend on the location, underlying function of that lung prior to radiations, radiation dose/fractionation and other factors. We propose to evaluate the radiation induced pulmonary function change using static breath-hold MRI scans with vascular infor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735033

    authors: Ding K,Cao K,Du K,Chen Q,Ennis D,Christensen G,Reinhardt J,Libby B,Benedict S,Sheng K

    更新日期:2012-06-01 00:00:00

  • Segmentation of bone CT images and assessment of bone structure using measures of complexity.

    abstract::A nondestructive and noninvasive method for numeric characterization (quantification) of the structural composition of human bone tissue has been developed and tested. In order to quantify and to compare the structural composition of bones from 2D computed tomography (CT) images acquired at different skeletal location...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2336501

    authors: Saparin P,Thomsen JS,Kurths J,Beller G,Gowin W

    更新日期:2006-10-01 00:00:00

  • SU-E-T-178: Optically Stimulated Luminescence (OSL) Dosimetry: A Study of A-Al2O3:C Assessed by PENELOPE Monte Carlo Simulation.

    abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735237

    authors: Nicolucci P,Schuch F

    更新日期:2012-06-01 00:00:00

  • Comparative assessment of linear least-squares, nonlinear least-squares, and Patlak graphical method for regional and local quantitative tracer kinetic modeling in cerebral dynamic 18 F-FDG PET.

    abstract:PURPOSE:Dynamic 18 F-FDG PET allows quantitative estimation of cerebral glucose metabolism both at the regional and local (voxel) level. Although sensitive to noise and highly computationally expensive, nonlinear least-squares (NLS) optimization stands as the reference approach for the estimation of the kinetic model p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13366

    authors: Ben Bouallègue F,Vauchot F,Mariano-Goulart D

    更新日期:2019-03-01 00:00:00

  • Ideal-observer detectability in photon-counting differential phase-contrast imaging using a linear-systems approach.

    abstract:PURPOSE:To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4739195

    authors: Fredenberg E,Danielsson M,Stayman JW,Siewerdsen JH,Aslund M

    更新日期:2012-09-01 00:00:00

  • A phantom for visualization of three-dimensional drug release by ultrasound-induced mild hyperthermia.

    abstract:PURPOSE:Ultrasound-induced mild hyperthermia has advantages for noninvasive, localized and controlled drug delivery. In this study, a tissue-mimicking agarose-based phantom with a thermally sensitive indicator was developed for studying the spatial drug delivery profile using ultrasound-induced mild hyperthermia. METH...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813299

    authors: Lai CY,Kruse D,Seo JW,Kheirolomoom A,Ferrara KW

    更新日期:2013-08-01 00:00:00

  • Sinusoidal modulation analysis for optical system MTF measurements.

    abstract::The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597840

    authors: Boone JM,Yu T,Seibert JA

    更新日期:1996-12-01 00:00:00

  • A deep feature fusion methodology for breast cancer diagnosis demonstrated on three imaging modality datasets.

    abstract:BACKGROUND:Deep learning methods for radiomics/computer-aided diagnosis (CADx) are often prohibited by small datasets, long computation time, and the need for extensive image preprocessing. AIMS:We aim to develop a breast CADx methodology that addresses the aforementioned issues by exploiting the efficiency of pre-tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12453

    authors: Antropova N,Huynh BQ,Giger ML

    更新日期:2017-10-01 00:00:00

  • Updated breast CT dose coefficients (DgNCT ) using patient-derived breast shapes and heterogeneous fibroglandular distributions.

    abstract:PURPOSE:The purpose of this work was to generate uncompressed heterogeneous breast phantom models using size-dependent fibroglandular distributions derived from a large cohort of breast CT (bCT) datasets, and to compare differences in normalized glandular dose coefficients for bCT "DgNCT " when the realistic heterogene...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13391

    authors: Hernandez AM,Becker AE,Boone JM

    更新日期:2019-03-01 00:00:00

  • The effects of target size and tissue density on the minimum margin required for random errors.

    abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1809991

    authors: Witte MG,van der Geer J,Schneider C,Lebesque JV,van Herk M

    更新日期:2004-11-01 00:00:00

  • Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer.

    abstract::Positron emission tomography (PET) has shown an increase in both sensitivity and specificity over computed tomography (CT) in lung cancer. However, motion artifacts in the 18F fluorodioxydoglucose (FDG) PET images caused by respiration persists to be an important factor in degrading PET image quality and quantificatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1448824

    authors: Nehmeh SA,Erdi YE,Ling CC,Rosenzweig KE,Squire OD,Braban LE,Ford E,Sidhu K,Mageras GS,Larson SM,Humm JL

    更新日期:2002-03-01 00:00:00

  • Deformable mapping technique to correlate lesions in digital breast tomosynthesis and automated breast ultrasound images.

    abstract:PURPOSE:To develop a deformable mapping technique to match corresponding lesions between digital breast tomosynthesis (DBT) and automated breast ultrasound (ABUS) images. METHODS:External fiducial markers were attached to the surface of two CIRS multi-modality compressible breast phantoms (A and B) containing multiple...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13113

    authors: Green CA,Goodsitt MM,Brock KK,Davis CL,Larson ED,Lau JH,Carson PL

    更新日期:2018-10-01 00:00:00

  • Use of 48Ca as a stable isotope tracer analyzed by proton activation.

    abstract::The use of the stable isotope 48Ca as a tracer in biological systems has been studied. Determination of 48Ca concentrations in samples was accomplished by proton activation via the (p,n) reaction with subsequent measurement of gamma-ray spectra from 44-h 48Sc and 4-h 44Sc. With protons of about 5.5 MeV and a Ge(Li) ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594303

    authors: Edwards FM,Kraushaar JJ,Ristinen RA,Rudolph H

    更新日期:1977-01-01 00:00:00

  • The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy.

    abstract::When treating prostate cancer using high dose rate (HDR) brachytherapy, overdosing the rectal wall may lead to post-treatment rectal complications. An area of concern is related to how the rectal wall dose is calculated by treatment planning systems (TPSs). TPSs are used to calculate the dose delivered to the rectal w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3031111

    authors: Kwan IS,Wilkinson D,Cutajar D,Lerch M,Rosenfeld A,Howie A,Bucci J,Chin Y,Perevertaylo VL

    更新日期:2009-01-01 00:00:00

  • An automatic seed finder for brachytherapy CT postplans based on the Hough transform.

    abstract:PURPOSE:The purpose of the work is to describe a new algorithm for the automatic detection of implanted radioactive seeds within the prostate. The algorithm is based on the traditional Hough transform. A method of quality assurance is described as well as a quantitative phantom study to determine the accuracy of the al...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1778837

    authors: Holupka EJ,Meskell PM,Burdette EC,Kaplan ID

    更新日期:2004-09-01 00:00:00

  • Discriminating solitary cysts from soft tissue lesions in mammography using a pretrained deep convolutional neural network.

    abstract:PURPOSE:It is estimated that 7% of women in the western world will develop palpable breast cysts in their lifetime. Even though cysts have been correlated with risk of developing breast cancer, many of them are benign and do not require follow-up. We develop a method to discriminate benign solitary cysts from malignant...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12110

    authors: Kooi T,van Ginneken B,Karssemeijer N,den Heeten A

    更新日期:2017-03-01 00:00:00

  • Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality.

    abstract:PURPOSE:To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. METHODS:In dual-energy CT, besides the material-specific information, one may also synthesi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3658568

    authors: Yu L,Christner JA,Leng S,Wang J,Fletcher JG,McCollough CH

    更新日期:2011-12-01 00:00:00

  • Evaluations of magnetic resonance imaging parameters with simple phantoms.

    abstract::Imaging parameters associated with a clinical magnetic resonance imaging (MRI) system, evaluated with the use of simple and inexpensive phantoms, are described in evaluation of a clinical MRI system. Images, obtained with a Diasonics 0.35-T MRI system using an elliptical whole-body radio frequency coil, are presented ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595894

    authors: Brateman L,Jennings LW,Nunnally RL,Vaughan JT

    更新日期:1986-07-01 00:00:00

  • Determining Pion, the correction factor for recombination losses in an ionization chamber.

    abstract::The 1983 AAPM protocol for the determination of absorbed dose from high-energy photon and electron beams recommends using Pion (the reciprocal of collection efficiency), as determined by the two-voltage technique, to correct for recombination losses in ionization chambers. Methods and data for the determination of ion...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595574

    authors: Weinhous MS,Meli JA

    更新日期:1984-11-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • Positional radiotherapy beam dosimetry using a laser heated thermoluminescent plate.

    abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596580

    authors: Kearfott KJ,Grupen-Shemansky ME

    更新日期:1990-05-01 00:00:00

  • Performance characteristics of transmission imaging using a uniform sheet source with parallel-hole collimation.

    abstract::Transmission imaging is receiving increasing attention in SPECT due to the need to compensate for nonuniform attenuation in cardiac-chest SPECT. The quality of a transmission image has an important effect on the measured attenuation distribution. To improve image quality, knowledge of the performance characteristics o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596752

    authors: Cao Z,Tsui BM

    更新日期:1992-09-01 00:00:00

  • Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation.

    abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14676

    authors: Ma J,Wang Y,An X,Ge C,Yu Z,Chen J,Zhu Q,Dong G,He J,He Z,Cao T,Zhu Y,Nie Z,Yang X

    更新日期:2020-12-23 00:00:00

  • Monte Carlo dose calculations for a new ovoid shield system for carcinoma of the uterine cervix.

    abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598459

    authors: Weeks KJ

    更新日期:1998-12-01 00:00:00

  • Cone-beam CT-derived relative stopping power map generation via deep learning for proton radiotherapy.

    abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14347

    authors: Harms J,Lei Y,Wang T,McDonald M,Ghavidel B,Stokes W,Curran WJ,Zhou J,Liu T,Yang X

    更新日期:2020-09-01 00:00:00