Sci-Fri PM: Planning-03: Fundamental understanding of the inter-relation of arc range, angular dose rate and MLC leaf position optimization of Intensity Modulated Arc Therapy for a concave target.

Abstract:

:Intensity Modulated Arc Therapy (IMAT) is a rotational variant of Intensity Modulated Radiation Therapy (IMRT) that can be implemented with or without angular dose rate optimization. The purpose of this study is to determine the inter-relationship among arc range, Multi-Leaf Collimator (MLC) leaf positions and angular dose rate optimizations for IMAT delivery of a concave target. A concave planning target volume (PTV) with central cylindrical organ at risk (OAR) was used in dissecting the inter-relationships. Plans with full and limited arc range were generated using leaf position optimization (LPO) alone, angular dose rate optimization (ADRO) alone or LPO followed by ADRO. Two initial IMAT arcs were conformal avoidance arcs created with 5° angular increments where MLC leaf positions were determined from the beams eye view to irradiate the PTV but avoid the OAR. The objective function value (evaluating dose to PTV and OAR), a conformity index, dose homogeneity index, mean dose to OAR and normal tissues were computed and used to evaluate the treatment plans. Dose rate variations and MLC leaf movements as a function of gantry angle were examined in this approach. The results demonstrate that LPO followed by ADRO provided the lowest objective function values, best conformity and dose homogeneity indices, and third in mean dose to OAR and normal tissues for the complete arc range. Future work will address different strategies for simultaneously optimizing both the MLC leaf positions and the variable angular dose rate for IMAT delivery and compare single and multiple arc plans.

journal_name

Med Phys

journal_title

Medical physics

authors

Oliver M,Chen J,Wong E

doi

10.1118/1.2965975

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

3412

issue

7Part3

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: characterization of dosimetric parameters including the interseed effect.

    abstract::Permanent implantation of 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast impl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3006151

    authors: Abboud F,Scalliet P,Vynckier S

    更新日期:2008-12-01 00:00:00

  • Accuracy evaluation of a six-degree-of-freedom couch using cone beam CT and IsoCal phantom with an in-house algorithm.

    abstract:PURPOSE:The accuracy of a six degree of freedom (6DoF) couch was evaluated using a novel method. METHODS:Cone beam CT (CBCT) images of a 3D phantom (IsoCal) were acquired with different, known combinations of couch pitch and roll angles. Pitch and roll angles between the maximum allowable values of 357 and 3 degrees w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12342

    authors: Zhang Q,Driewer J,Wang S,Li S,Zhu X,Zheng D,Cao Y,Zhang J,Jamshidi A,Cox BW,Knisely JPS,Potters L,Klein EE

    更新日期:2017-08-01 00:00:00

  • A model to simulate the oxygen distribution in hypoxic tumors for different vascular architectures.

    abstract:PURPOSE:As hypoxic cells are more resistant to photon radiation, it is desirable to obtain information about the oxygen distribution in tumors prior to the radiation treatment. Noninvasive techniques are currently not able to provide reliable oxygenation maps with sufficient spatial resolution; therefore mathematical m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812431

    authors: Espinoza I,Peschke P,Karger CP

    更新日期:2013-08-01 00:00:00

  • A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices.

    abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1800712

    authors: Prisciandaro JI,Frechette CM,Herman MG,Brown PD,Garces YI,Foote RL

    更新日期:2004-11-01 00:00:00

  • Development and clinical implementation of semi-automated treatment planning including 3D printable applicator holders in complex skin brachytherapy.

    abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13975

    authors: Guthier CV,Devlin PM,Harris TC,O'Farrell DA,Cormack RA,Buzurovic I

    更新日期:2020-03-01 00:00:00

  • Experimental determination of the "collimator monitoring fill factor" and its relation to the error detection capabilities of various 2D-arrays.

    abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13417

    authors: Stelljes TS,Poppinga D,Kretschmer J,Brodbek L,Looe HK,Poppe B

    更新日期:2019-04-01 00:00:00

  • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production.

    abstract:PURPOSE:The aim of this study is to understand the characteristics of secondary electrons generated from the interaction of gold nanoparticles (GNPs) with x-rays as a function of nanoparticle size and beam energy and thereby further the understanding of GNP-enhanced radiotherapy. METHODS:The effective range, deflectio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539623

    authors: Leung MK,Chow JC,Chithrani BD,Lee MJ,Oms B,Jaffray DA

    更新日期:2011-02-01 00:00:00

  • Computer-aided detection of mammographic microcalcifications: pattern recognition with an artificial neural network.

    abstract::We are developing a computer program for automated detection of clustered microcalcifications on mammograms. In this study, we investigated the effectiveness of a signal classifier based on a convolution neural network (CNN) approach for improvement of the accuracy of the detection program. Fifty-two mammograms with c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597428

    authors: Chan HP,Lo SC,Sahiner B,Lam KL,Helvie MA

    更新日期:1995-10-01 00:00:00

  • Objected constrained registration and manifold learning: a new patient setup approach in image guided radiation therapy of thoracic cancer.

    abstract:PURPOSE:The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. METHODS:For 11 lung cancer patients a long training fluoroscopy was acquired before the first trea...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.4794489

    authors: Chen T,Jabbour SK,Qin S,Haffty BG,Yue N

    更新日期:2013-04-01 00:00:00

  • Water-equivalent dosimeter array for small-field external beam radiotherapy.

    abstract::With the increasing complexity of dose patterns external beam radiotherapy, there is a great need for new types of dosimeters. We studied the first prototype of a new dosimeter array consisting of water-equivalent plastic scintillating fibers for dose measurement in external beam radiotherapy. We found that this array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2719363

    authors: Archambault L,Beddar AS,Gingras L,Lacroix F,Roy R,Beaulieu L

    更新日期:2007-05-01 00:00:00

  • A new method to combine 3D reconstruction volumes for multiple parallel circular cone beam orbits.

    abstract:PURPOSE:This article presents a new reconstruction method for 3D imaging using a multiple 360 degrees circular orbit cone beam CT system, specifically a way to combine 3D volumes reconstructed with each orbit. The main goal is to improve the noise performance in the combined image while avoiding cone beam artifacts. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3484058

    authors: Baek J,Pelc NJ

    更新日期:2010-10-01 00:00:00

  • Reconstruction of electron spectra using singular component decomposition.

    abstract::Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unst...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1461840

    authors: Chvetsov AV,Sandison GA

    更新日期:2002-04-01 00:00:00

  • Technical note: A novel boundary condition using contact elements for finite element based deformable image registration.

    abstract::Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1774131

    authors: Zhang T,Orton NP,Mackie TR,Paliwal BR

    更新日期:2004-09-01 00:00:00

  • Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry.

    abstract:PURPOSE:The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, howev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13253

    authors: van der Velden S,Dietze MMA,Viergever MA,de Jong HWAM

    更新日期:2019-01-01 00:00:00

  • Dose homogeneity specification for reference dosimetry of nonstandard fields.

    abstract:PURPOSE:To investigate the sensitivity of the plan-class specific correction factor to dose distributions in composite nonstandard field dosimetry. METHODS:A cylindrical water-filled PMMA phantom was constructed at the center of which reference absorbed dose could be measured. Ten different TomoTherapy(®)-based IMRT f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3669487

    authors: Chung E,Soisson E,Seuntjens J

    更新日期:2012-01-01 00:00:00

  • A neural network approach for fast, automated quantification of DIR performance.

    abstract:PURPOSE:A critical step in adaptive radiotherapy (ART) workflow is deformably registering the simulation CT with the daily or weekly volumetric imaging. Quantifying the deformable image registration accuracy under these circumstances is a complex task due to the lack of known ground-truth landmark correspondences betwe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12321

    authors: Neylon J,Min Y,Low DA,Santhanam A

    更新日期:2017-08-01 00:00:00

  • A water phantom controller for automated acquisition of linac beam parameters.

    abstract::Three-dimensional water phantoms are routinely used when acquiring the data necessary to commission medical linear accelerators. A new water phantom controller has been developed at our institution that is unique in several aspects. The water phantom controller is based on an IBM XT compatible computer. This has been ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596414

    authors: Schmid MG,Morris RL

    更新日期:1989-01-01 00:00:00

  • The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study.

    abstract::The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207212

    authors: Tzedakis A,Perisinakis K,Raissaki M,Damilakis J

    更新日期:2006-07-01 00:00:00

  • Technical Note: Performance comparison of ultra-high-resolution scan modes of two clinical computed tomography systems.

    abstract:PURPOSE:Two ultra-high-resolution (UHR) computed tomography (CT) scanners are clinically available. One is achieved by a CT system with a 0.25 mm × 160 row detector (Detector-UHR), whereas the other is with a 0.6 mm × 32 row detector with in-plane comb filtering in a dual source CT (Comb-UHR). We compared radiation dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13949

    authors: Kawashima H,Ichikawa K,Takata T,Nagata H,Hoshika M,Akagi N

    更新日期:2020-02-01 00:00:00

  • In vivo surface dosimetry with a scintillating fiber dosimeter in preclinical image-guided radiotherapy.

    abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13903

    authors: Le Deroff C,Pérès EA,Ledoux X,Toutain J,Frelin-Labalme AM

    更新日期:2020-01-01 00:00:00

  • SU-E-T-567: Improve Dose Conformity with IMRT Using Shorter Source to Tumor Distance.

    abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735656

    authors: Yang W,Sandler H,Fraass B

    更新日期:2012-06-01 00:00:00

  • Review and evaluation of MRI nonuniformity corrections for brain tumor response measurements.

    abstract::Current MRI nonuniformity correction techniques are reviewed and investigated. Many approaches are used to remedy this artifact, but it is not clear which method is the most appropriate in a given situation, as the applications have been with different MRI coils and different clinical applications. In this work four w...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.598357

    authors: Velthuizen RP,Heine JJ,Cantor AB,Lin H,Fletcher LM,Clarke LP

    更新日期:1998-09-01 00:00:00

  • A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates.

    abstract::The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598412

    authors: Kengyelics SM,Davies AG,Cowen AR

    更新日期:1998-11-01 00:00:00

  • Dose rate and SDD dependence of commercially available diode detectors.

    abstract::The dose-rate dependence of commercially available diode detectors was measured under both high instantaneous dose-rate (pulsed) and low dose rate (continuous, Co-60) radiation. The dose-rate dependence was measured in an acrylic miniphantom at a 5-cm depth in a 10 x 10 cm2 collimator setting, by varying source-to-det...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1650563

    authors: Saini AS,Zhu TC

    更新日期:2004-04-01 00:00:00

  • Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain.

    abstract:PURPOSE:The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. METHODS:The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4918321

    authors: Jung JH,Choi Y,Jung J,Kim S,Lim HK,Im KC,Oh CH,Park HW,Kim KM,Kim JG

    更新日期:2015-05-01 00:00:00

  • Multipinhole collimator with 20 apertures for a brain SPECT application.

    abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897567

    authors: Lee TC,Ellin JR,Huang Q,Shrestha U,Gullberg GT,Seo Y

    更新日期:2014-11-01 00:00:00

  • Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

    abstract:PURPOSE:Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3560428

    authors: Gang GJ,Lee J,Stayman JW,Tward DJ,Zbijewski W,Prince JL,Siewerdsen JH

    更新日期:2011-04-01 00:00:00

  • Static multileaf collimator for fast-neutron therapy.

    abstract::This paper describes a multileaf collimator, designed to obtain irregularly shaped neutron fields, that fits into an existing fixed field-size collimator system. The shape of the desired portal field is obtained by appropriately setting the position of each leaf of the collimator. The collimator consists of 40 polyeth...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596084

    authors: Chu JC,Bloch P

    更新日期:1987-03-01 00:00:00

  • Verification of radiotherapy treatments: computerized analysis of the size and shape of radiation fields.

    abstract::An automated technique has been developed for the verification of treatment field size and shape in external beam radiation therapy. Portal images from film or digital on-line imaging system are analyzed, and basic parameters are derived to describe the field size and shape from the contour points on the field boundar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597017

    authors: Leszczynski KW,Shalev S,Gluhchev G

    更新日期:1993-05-01 00:00:00

  • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.

    abstract::Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2746492

    authors: Brisse HJ,Madec L,Gaboriaud G,Lemoine T,Savignoni A,Neuenschwander S,Aubert B,Rosenwald JC

    更新日期:2007-07-01 00:00:00