Abstract:
:Quantification of transit time of a remote after-loading high dose rate (HDR) brachytherapy source is important both for accurate treatment planning and for quality assurance checks. In this investigation, an HDR-1000 well ionization chamber and a precision electrometer are used to measure the transit time of the Ir-192 source of a Nucletron Micro-Selectron HDR brachytherapy unit. The charge generated both during source dwelling at a selected position in an endobronchial catheter inserted into the chamber and during source travel to this position from another location at a distance of 0.5 to 10 cm from it was measured. A linear regression analysis of the measured charge as a function of dwell time was made. The interdwell position transit time was calculated from the ratio of the charge intercept and the slope of the straight line obtained from the regression analysis. The values of the effective transit time, which is a combination of interdwell position transit time and dwell time error of the after-loading unit, were found to be 0.03 and 0.45 s for 0.5 and 10 cm separation between two dwell positions, respectively. The average time for 1 cm travel of the source between two dwell positions was found to be 0.022 s, resulting in an average speed of 45.5 cm/s. This simple procedure has the potential to be utilized for routine quality assurance check of the interdwell position transit time of any remote after-loading HDR brachytherapy source.
journal_name
Med Physjournal_title
Medical physicsauthors
Sahoo Ndoi
10.1118/1.1386779subject
Has Abstractpub_date
2001-08-01 00:00:00pages
1786-90issue
8eissn
0094-2405issn
2473-4209journal_volume
28pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The complex beam delivery techniques for patient treatment using a clinical linear accelerator (linac) may result in variations in the photon spectra, which can lead to dosimetric differences in patients that cannot be accounted for by current treatment planning systems (TPSs). Therefore, precise knowledge of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13569
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4870378
更新日期:2014-05-01 00:00:00
abstract::Diode sensitivity variations with temperature (SVWT) have been reported to vary from small negative values up to 0.6% per degrees C. Thus it is possible for diode calibration factors established at room temperature (approximately 20 degrees C) to yield errors in the range of -1% to +9% when diodes are placed on a pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1367862
更新日期:2001-05-01 00:00:00
abstract::A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597608
更新日期:1995-04-01 00:00:00
abstract:PURPOSE:Transcranial focused ultrasound is an emerging therapeutic modality that can be used to perform noninvasive neurosurgical procedures. The current clinical transcranial phased array operates at 650 kHz, however the development of a higher frequency array would enable more precision, while reducing the risk of st...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4829510
更新日期:2013-12-01 00:00:00
abstract::A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598500
更新日期:1999-02-01 00:00:00
abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4826166
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792636
更新日期:2013-03-01 00:00:00
abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598839
更新日期:2000-02-01 00:00:00
abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1630492
更新日期:2004-01-01 00:00:00
abstract::We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1737492
更新日期:2004-06-01 00:00:00
abstract::A beam intensity monitor was tested in a 230-MeV proton beam at the Loma Linda Proton Therapy Accelerator during its commissioning at Fermi National Accelerator Laboratory. The intensity monitor was designed to regulate the beam intensity extracted from the proton synchrotron. The proton beam is tunable between 70 and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596636
更新日期:1991-07-01 00:00:00
abstract::Segmentation of the lungs within magnetic resonance (MR) scans is a necessary step in the computer-based analysis of thoracic MR images. This process is often confounded by image acquisition artifacts and disease-induced morphological deformation. We have developed an automated method for lung segmentation that is ins...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2214165
更新日期:2006-09-01 00:00:00
abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598293
更新日期:1998-06-01 00:00:00
abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2133718
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. METHODS:MD Anderson Cancer Center Institutional Review Board appro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4906178
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3447727
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735656
更新日期:2012-06-01 00:00:00
abstract::Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, ap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595027
更新日期:1981-09-01 00:00:00
abstract:PURPOSE:Periprocedural assessment of tissue perfusion by imaging methods could improve outcome control during treatment of peripheral vascular disease. Currently, endovascular revascularization treatments are assessed by planar angiography which only allows for qualitative inspection of blood flow in vessels. In this p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679864
更新日期:2012-03-01 00:00:00
abstract::A suitable was phantom was designed for evaluating various film techniques used in subtraction radiography. Holes are drilled in a slab of wax and filled with various concentrations of iodinated wax, producing disk-shaped regions with diffuse borders. The technical details of construction and a representative applicat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594371
更新日期:1977-05-01 00:00:00
abstract::We measured the physical imaging performance of a 41 x 41 cm2 amorphous silicon flat panel detector designed for angiographic and R&F imaging applications using methods from the emerging IEC standard for the measurement of detective quantum efficiency (DQE) in digital radiographic detectors. Measurements on 12 product...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1609151
更新日期:2003-10-01 00:00:00
abstract::Permanent implants of 125I seeds at Memorial Sloan-Kettering Cancer Center are performed by the method of "dimension averaging" to determine the total activity to be implanted; that is, the activity (in mCi) is taken to be five times the average dimension (in cm) of the target region. A nomograph has recently been dev...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594269
更新日期:1976-01-01 00:00:00
abstract:PURPOSE:Incorporating training into image segmentation is a good approach to achieve additional robustness. This work aims to develop an effective strategy to utilize shape prior knowledge, so that the segmentation label evolution can be driven toward the desired global optimum. METHODS:In the variational image segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4945046
更新日期:2016-05-01 00:00:00
abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00
abstract::Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and char...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1477230
更新日期:2002-06-01 00:00:00
abstract:PURPOSE:The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimet...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3651695
更新日期:2011-11-01 00:00:00
abstract::The gamma index is a tool that compares a dose distribution with a reference distribution by combining dose-difference and distance-to-agreement criteria. It has been widely used for ten years despite its high computational cost. This cost is due to both a search process for each reference point and the necessity to r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3070546
更新日期:2009-03-01 00:00:00
abstract:PURPOSE:To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)]. METHODS:A voxel-based tissue model c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892386
更新日期:2014-09-01 00:00:00
abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598654
更新日期:1999-08-01 00:00:00