Abstract:
:A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT imaging systems that was simple, practical, required minimal test equipment, and could be performed in a few hours using processing software available on all nuclear medicine computers. It was designed to test rotational stability of uniformity and sensitivity, tomographic spatial resolution, uniformity and contrast, and the accuracy of attenuation correction. It can be performed in less than three hours and requires only a Co-57 flood source, a line source, and a tomographic cylindrical phantom. The protocol was used 51 times on 42 different cameras (seven vendors) by four different individuals. The results were used to establish acceptable ranges for the measured parameters. The variation between vendors was relatively small and appeared to reflect slight differences in basic camera performance, collimation, and reconstruction software. Individuals can use the tabulated values to evaluate the performance of individual systems.
journal_name
Med Physjournal_title
Medical physicsauthors
Graham LS,Fahey FH,Madsen MT,van Aswegen A,Yester MVdoi
10.1118/1.597605subject
Has Abstractpub_date
1995-04-01 00:00:00pages
401-9issue
4eissn
0094-2405issn
2473-4209journal_volume
22pub_type
指南,杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:For almost four decades bead and wire ramps have been used in the evaluation of slice width as part of QA testing for CT scanners. While each of these approaches have been recognized and accepted as reliable, in this paper we investigate the differences, advantages and limitations of these tools. Moreover, we s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734753
更新日期:2012-06-01 00:00:00
abstract::Lag and residual contrast have been quantified in an amorphous selenium (a-Se) active-matrix flat-panel imager (AMFPI) as a function of frame time, kilovoltage (kV) and megavoltage (MV) x-ray photon energies and amount of radiation incident on the detector. The AMFPI contains a 200 microm thick a-Se layer deposited on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1713298
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:In our institute, the MatriXX has been used for IMRT, VMAT and dynamic arc QA. However, the small fields (<3cm) shaped by HDMLC for SRS dynamic arc (DA) present QA measurement issues when using the MatriXX due to its limited resolution (7.6 mm). A recently available portal dosimetry (PD) software tool in Eclips...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735167
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water equivalent electronic portal imaging device (WE-EPID) and a conventional treatment planning system (TPS). METHOD AND MATERIALS:A standard amorphous silicon (a-Si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12742
更新日期:2018-03-01 00:00:00
abstract::We proposed to use the prostate dose-volume factor (PDVF), derived from the dose-volume dataset of planning target volume (PTV) in prostate radiotherapy to evaluate treatment plans of prostate volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT). To demonstrate plan evaluation using PDVF...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740167
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. METHODS:Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4729738
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939255
更新日期:2016-02-01 00:00:00
abstract::In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1668391
更新日期:2004-04-01 00:00:00
abstract:PURPOSE:The authors' objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-sp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4892606
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:The repair rate conventionally assumed to be constant during the entire radiation course. However, increasing evidences from animal studies show that the repair process may slow down with time and the experimental data does not fit an exponential pattern. To address this enigma, we presented a generalized linea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735058
更新日期:2012-06-01 00:00:00
abstract::A 4 x 500 mm2 "cloverleaf" low energy germanium detector array has been assembled for the purpose of in vivo bone lead measurement through x-ray fluorescence. Using 109Cd as an exciting source, results are reported from a leg phantom simulating measurement of lead in a human tibia. For high activity (4.0-4.4 GBq) and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2436973
更新日期:2007-03-01 00:00:00
abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4817482
更新日期:2013-09-01 00:00:00
abstract::A method is presented for calculation of transmission functions for high energy photon beams through patients. These functions are being used in our clinic for prediction of portal dose images (PDIs) which are compared with PDIs measured with an electronic portal imaging device (EPID). The calculations are based on th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598293
更新日期:1998-06-01 00:00:00
abstract::A new rubber band straightening transform (RBST) is introduced for characterization of mammographic masses as malignant or benign. The RBST transforms a band of pixels surrounding a segmented mass onto the Cartesian plane (the RBST image). The border of a mammographic mass appears approximately as a horizontal line, a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598228
更新日期:1998-04-01 00:00:00
abstract::Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3075901
更新日期:2009-03-01 00:00:00
abstract::Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3158731
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13952
更新日期:2020-02-01 00:00:00
abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596252
更新日期:1988-03-01 00:00:00
abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595642
更新日期:1984-09-01 00:00:00
abstract::We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four l...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1809778
更新日期:2004-12-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract:PURPOSE:Over the last four decades, Ocular Proton Therapy has been successfully used to treat patients affected by intraocular lesions. For this, treatment geometry verification is routinely performed using radiographic images to align a configuration of fiducial radiopaque markers implanted on the sclera outer surface...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12841
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12939
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR20,10) for a square field of 10 x 10 cm2 and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3197062
更新日期:2009-09-01 00:00:00
abstract::The American Association of Physicists in Medicine recommends that the reference dose-rate distribution, used for treatment planning for low-energy photon brachytherapy sources in routine clinical use, must be based on at least two independent determinations: one using experimentally measured dose rates and one using ...
journal_title:Medical physics
pub_type: 指南,杂志文章
doi:10.1118/1.1690712
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:Automated segmentation of brain structures (objects) in MR three-dimensional (3D) images for quantitative analysis has been a challenge and probabilistic atlases (PAs) are among the most well-succeeded approaches. However, the existing models do not adapt to possible object anomalies due to the presence of a di...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13771
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attai...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14116
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. METHODS:Twenty-two consecutive patients were enrolled in a pro...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.4915534
更新日期:2015-04-01 00:00:00
abstract::In previous work it has been shown that a standard backpropagation neural network can be trained to reconstruct sections of single photon emission computed tomography (SPECT) images based on the planar image projections as inputs. In this study, it is demonstrated that an artificial neural network (ANN) trained on a s...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597586
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4931964
更新日期:2015-11-01 00:00:00