Abstract:
:In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.
journal_name
Med Physjournal_title
Medical physicsauthors
Vetterli D,Riem H,Aebersold DM,Greiner RH,Manser P,Cossmann P,Kemmerling L,Born EJ,Mini Rdoi
10.1118/1.1668391subject
Has Abstractpub_date
2004-04-01 00:00:00pages
828-31issue
4eissn
0094-2405issn
2473-4209journal_volume
31pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::The image artifacts characteristic of a scanning chest radiographic system are reviewed. The technique employs a pulsed beam of radiation swept in an overlapping raster pattern that can result in severe ripple and scan line artifacts with improper scanning parameters. A one-dimensional treatment of the scanner geometr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595492
更新日期:1984-03-01 00:00:00
abstract::Stereo x-ray radiography attracts increasing attention in major clinical applications. The purpose of this paper is to analyze the 3D localization error for breast biopsy procedures and provide guidelines for improving its accuracy. Our prototype is a CCD based digital stereo x-ray imaging system. The mathematical mod...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598953
更新日期:2000-05-01 00:00:00
abstract:PURPOSE:The Imaging and Radiation Oncology Core Houston (IROC-H) (formerly the Radiological Physics Center) has reported varying levels of agreement in their anthropomorphic phantom audits. There is reason to believe one source of error in this observed disagreement is the accuracy of the dose calculation algorithms an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12426
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:TransitQA is an innovative method for Tomotherapy transit dosimetry using the on-board detector (OBD). Our previously published model for Tomotherapy treatment plan verification (AirQA) has been enhanced to take into account patient and couch transmission. AirQA estimates the OBD signal during irradiation with ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12672
更新日期:2018-01-01 00:00:00
abstract::The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawbac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508110
更新日期:2002-10-01 00:00:00
abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1489044
更新日期:2002-07-01 00:00:00
abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2964092
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:In this work, the fabrication, operation, and evaluation of a probe-format graphite calorimeter - herein referred to as Aerrow - as an absolute clinical dosimeter of high-energy photon beams while in the presence of a B = 1.5 T magnetic field is described. Comparable to a cylindrical ionization chamber (IC) in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13968
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:There are growing expectations that imaging biomarkers for tumor therapeutic drug response assessment will speed up preclinical testing of anticancer drugs in rodent models. The only imaging biomarker presently approved by the U.S. Food and Drug Administration is tumor size measurement based on either World Hea...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3464491
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:Variations during breast tissue development can influence later breast cancer risk. In particular, prolonged nulliparity increases risk. The authors used optical spectroscopy to compare breast tissue in 115 nulliparous women aged 31-40 (group 2) to 140 nulliparous women aged 18-21 (group 1), and also to 36 paro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3276737
更新日期:2010-02-01 00:00:00
abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598743
更新日期:1999-11-01 00:00:00
abstract:PURPOSE:Two-dimensional antiscatter grids (2DASG) for cone beam computed tomography (CBCT) is a new area of research to reduce scatter intensity, and consequently improve CBCT image quality. One of the challenges in implementation of 2DASGs is their septa shadows that are impinged on the projections. If these artifacts...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13456
更新日期:2019-05-01 00:00:00
abstract::A Monte Carlo method was developed and implemented to simulate x-ray photon transport. Simulations consisted of a pencil beam of monoenergetic photons with energies from 50 to 110 keV incident on water and aluminum slabs. The dependence of scatter fraction and multiple scattering on x-ray energy, scatterer thickness, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596268
更新日期:1988-11-01 00:00:00
abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3222872
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12677
更新日期:2018-01-01 00:00:00
abstract::The American Association of Physicists in Medicine Radiation Therapy Committee Task Group 36 report (TG-36) provides guidelines for managing radiation therapy of pregnant patients. Included in the report are data that can be used to estimate the dose to the fetus. The purpose of this study is to evaluate the accuracy ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2710332
更新日期:2007-04-01 00:00:00
abstract::Optical-resolution photoacoustic microscopy (OR-PAM) has been validated as a valuable tool for label-free volumetric microvascular imaging. More importantly, the advantages of noninvasiveness and measurement consistency suggest the use of OR-PAM for chronic imaging of intact microcirculation. Here, such chronic imagin...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.3137572
更新日期:2009-06-01 00:00:00
abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14347
更新日期:2020-09-01 00:00:00
abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2739805
更新日期:2007-07-01 00:00:00
abstract:PURPOSE:One limitation of positron emission tomography (PET) imaging of the torso is patient motion. Motion-compensated image reconstruction (MCIR) is one method employed to reduce the deleterious effects of motion. Existing MCIR algorithms use a single sensitivity correction term, which provides inexact normalization ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3611041
更新日期:2011-09-01 00:00:00
abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735574
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:We have developed a robust tool for performing volumetric and temporal analysis of nodules from respiratory gated four-dimensional (4D) CT. The method could prove useful in IMRT of lung cancer. METHODS:We modified the conventional graph-cuts method by adding an adaptive shape prior as well as motion informatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12690
更新日期:2018-01-01 00:00:00
abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3117563
更新日期:2009-05-01 00:00:00
abstract::An optimization analysis of digital fluoroscopy has been carried out using (signal/noise)2/dose as a figure of merit. Three signal detection tasks have been considered: (i) small iodine-containing blood vessels; (ii) regions of fat; and (iii) microcalcifications. The effects of x-ray beam filtration and kilovoltage on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595130
更新日期:1982-09-01 00:00:00
abstract:PURPOSE:To investigate whether functionally-weighted dose-volume histogram (DVH) parameters are more predictive of radiation-induced pneumonitis (RP) than standard parameters such as V20 and mean lung dose (MLD). MATERIALS AND METHODS:A retrospective chart review identified 26 patients who received curative-intent rad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740190
更新日期:2012-07-01 00:00:00
abstract::Our purpose in this work was to assess the reliability of the calibration coefficient for magnetic resonance water proton chemical shift temperature mapping. Over a six month period, the calibration coefficient was measured 15 times in several different phantoms. A highly linear relationship between water proton chemi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598864
更新日期:2000-01-01 00:00:00
abstract:PURPOSE:MR thermometry based on the proton resonance frequency shift (PRFS) is the most commonly used method for the monitoring of thermal therapies. As the chemical shift of water protons is temperature dependent, the local temperature variation (relative to an initial baseline) may be calculated from time-dependent p...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3309439
更新日期:2010-04-01 00:00:00
abstract::This paper is concerned with the proposed Birmingham accelerator-based epithermal neutron beam for boron neutron capture therapy (BNCT). In particular, the option of producing a therapy beam at an orthogonal direction to the incoming protons is considered. Monte Carlo radiation transport simulations, both with and wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598479
更新日期:1999-01-01 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:Polymer-based gel dosimeter (MAGIC type) is a preferable phantom material for PET range verification of proton beam therapy. However, improvement in elemental tissue equivalency (specifically O/C ratio) is very desirable to ensure realistic time-activity measurements. METHODS:Glucose and urea was added to the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3260844
更新日期:2010-01-01 00:00:00