Abstract:
PURPOSE:The Imaging and Radiation Oncology Core Houston (IROC-H) (formerly the Radiological Physics Center) has reported varying levels of agreement in their anthropomorphic phantom audits. There is reason to believe one source of error in this observed disagreement is the accuracy of the dose calculation algorithms and heterogeneity corrections used. To audit this component of the radiotherapy treatment process, an independent dose calculation tool is needed. METHODS:Monte Carlo multiple source models for Elekta 6 MV and 10 MV therapeutic x-ray beams were commissioned based on measurement of central axis depth dose data for a 10 × 10 cm2 field size and dose profiles for a 40 × 40 cm2 field size. The models were validated against open field measurements consisting of depth dose data and dose profiles for field sizes ranging from 3 × 3 cm2 to 30 × 30 cm2 . The models were then benchmarked against measurements in IROC-H's anthropomorphic head and neck and lung phantoms. RESULTS:Validation results showed 97.9% and 96.8% of depth dose data passed a ±2% Van Dyk criterion for 6 MV and 10 MV models respectively. Dose profile comparisons showed an average agreement using a ±2%/2 mm criterion of 98.0% and 99.0% for 6 MV and 10 MV models respectively. Phantom plan comparisons were evaluated using ±3%/2 mm gamma criterion, and averaged passing rates between Monte Carlo and measurements were 87.4% and 89.9% for 6 MV and 10 MV models respectively. CONCLUSIONS:Accurate multiple source models for Elekta 6 MV and 10 MV x-ray beams have been developed for inclusion in an independent dose calculation tool for use in clinical trial audits.
journal_name
Med Physjournal_title
Medical physicsauthors
Faught AM,Davidson SE,Fontenot J,Kry SF,Etzel C,Ibbott GS,Followill DSdoi
10.1002/mp.12426subject
Has Abstractpub_date
2017-09-01 00:00:00pages
4943-4951issue
9eissn
0094-2405issn
2473-4209journal_volume
44pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792462
更新日期:2013-03-01 00:00:00
abstract::The dosimetry for radiocolloid therapy of cystic craniopharyngiomas is investigated. Analytical calculations based on the Loevinger and the Berger formulas for electrons and photons, respectively, are compared with Monte Carlo simulations. The role of the material of which the colloid introduced inside the craniophary...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1599653
更新日期:2003-09-01 00:00:00
abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1861161
更新日期:2005-03-01 00:00:00
abstract::The Gafchromic EBT was recently introduced in film dosimetry for external beam therapy (EBT). The high spatial resolution, weak energy dependence, and near-tissue equivalence of EBT films make them suitable for measurement of dose distributions in radiotherapy, especially intensity-modulated radiation therapy (IMRT). ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2362876
更新日期:2006-11-01 00:00:00
abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596336
更新日期:1989-09-01 00:00:00
abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594657
更新日期:1980-01-01 00:00:00
abstract::An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure spectral distribution is reconstructe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596495
更新日期:1990-07-01 00:00:00
abstract:PURPOSE:Integrating a linac with a magnetic resonance imager (MRI) will revolutionize the accuracy of external beam radiation treatments. Irradiating in the presence of a strong magnetic field, however, will modify the dose distribution. These dose modifications have been investigated previously, mainly using Monte Car...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12413
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Real-time sub-millimeter head motion compensation during frameless SRS delivery has the potential to achieve the accuracy of frame-based SRS while being significantly less invasive. Previously, we demonstrated real-time 6D head motion monitoring using an optical camera, however, at the time we were limited to o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734995
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13372
更新日期:2019-03-01 00:00:00
abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965923
更新日期:2008-07-01 00:00:00
abstract::Double checking of the monitor units (MU) is an important step in the quality assurance (QA) process in radiosurgery. In this paper we propose the use of an independent algorithm constructed using the ellipsoid which best fits the measurements taken with the bubble head frame. The monitor units calculated by this inde...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2815361
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. METHODS:Using a departmental incident learning system, eight incidents were noted over a two-y...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760774
更新日期:2012-11-01 00:00:00
abstract::A direct data link between a CT scanner and a radiation treatment planning system has been developed. The link transmits the data serially over a coaxial cable using the pseudo-paper-tape punch and reader (serial PIO) interfaces. The data transmission rate with error-check is approximately 25,000 8-bit bytes/s. This t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594536
更新日期:1979-09-01 00:00:00
abstract:PURPOSE:Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754799
更新日期:2012-10-01 00:00:00
abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2936229
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4864474
更新日期:2014-03-01 00:00:00
abstract:PURPOSE:With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4887813
更新日期:2014-08-01 00:00:00
abstract::A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1470205
更新日期:2002-05-01 00:00:00
abstract::The image display is an important component of the Picture Archiving and Communication System (PACS) and of digital imaging in general. In this paper, we assess the display performance of 32 different flat panel LCD devices, in terms of their reflection, luminance response, luminance uniformity, resolution, noise, vei...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1764946
更新日期:2004-07-01 00:00:00
abstract::The Los Alamos code MCNP4A (Monte Carlo N-Particle version 4A) is currently used to simulate a variety of problems ranging from nuclear reactor analysis to boron neutron capture therapy. A graphical user interface has been developed that automatically sets up the MCNP4A geometry and radiation source requirements for a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598167
更新日期:1998-01-01 00:00:00
abstract::Separation of water from fat tissues in magnetic resonance imaging is important for many applications because signals from fat tissues often interfere with diagnoses that are usually based on water signal characteristics. Water and fat can be separated with images acquired at different echo time shifts. The three-poin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2952644
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:To evaluate plan quality of a novel MRI-compatible direction modulated brachytherapy (DMBT) tandem applicator using 192 Ir, 60 Co, and 169 Yb HDR brachytherapy sources, for various cervical cancer high-risk clinical target volumes (CTVHR ). MATERIALS AND METHODS:The novel DMBT tandem applicator has six periphe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12598
更新日期:2017-12-01 00:00:00
abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1517613
更新日期:2002-11-01 00:00:00
abstract::We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596402
更新日期:1989-01-01 00:00:00
abstract::Neutron energy spectra and spectra of dose deposition in tissue-equivalent material have been measured for neutron sources produced by 16-, 22-, 35-, and 45.5-MeV deuterons and 22.5-, 35-, 45-, and 65.5-MeV protons incident upon a thick beryllium target. Neutron spectra were measured using time-of-flight techniques an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594392
更新日期:1977-05-01 00:00:00
abstract::In addition to the familiar problems of reduced contrast and signal-to-noise ratio (SNR) in the single energy case, dual-energy subtractions in the presence of scattered radiation suffer further degradations from: (1) artifacts due to nonuniform subtraction of scatter, and (2) a serious deterioration of the signal of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596188
更新日期:1988-09-01 00:00:00
abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595546
更新日期:1984-09-01 00:00:00
abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597688
更新日期:1996-04-01 00:00:00