Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging.

Abstract:

PURPOSE:Positron emission tomography (PET) is considered the gold standard for measuring myocardial blood flow in vivo but it is known that respiratory motion can lead to misalignment of the PET and computed tomography (CT) data sets and introduce artifacts in the CT-based attenuation correction (AC) of images. In addition, respiratory motion blurs the PET image and degrades spatial resolution. The purpose of this study is to evaluate the combined effect of respiratory motion compensation (MC) and accurate attenuation correction on relative and absolute blood flow imaging of the heart. METHODS:Dynamic (82)Rb-PET acquisitions were generated for a homogeneous tracer distribution in the heart using an anthropomorphic computer phantom and a Monte Carlo simulator. Attenuation correction was done using three different approaches in which the PET data were corrected by: (1) a respiratory-gated CT map with each respiratory phase of the PET scan corrected by its corresponding CT phase (matched); (2) a time-averaged attenuation map (avg); or (3) an attenuation map generated from the maximum CT-number of every voxel over the respiratory cycle (max). Motion compensated was done using an automated rigid-body registration algorithm that aligned all of the phases of the respiratory-gated PET data after AC. The corrected dynamic PET data were then processed by inhouse kinetic analysis software to generate 3D maps of blood flow. Polar maps of the blood-flow for each CT-AC method with and without MC were compared to the truth using a 17-segment model. The same comparison was performed on data from a pig study. RESULTS:Motion compensation significantly reduced the segmental mean percentage error (sMPE) in all cases (p < 0.01 for matched CTAC and avg CTAC and p = 0.03 for max CTAC). MC significantly increased image uniformity in the case of matched and avg CTAC (p < 0.01, p = 0.04, respectively) with the best improvement coming for matched CTAC. Without MC, there were no significant differences between the three CTAC approaches. With MC, matched CTAC had significantly smaller mean absolute sMPE (p < 0.01 vs avg CTAC; p < 0.01 vs max CTAC) and improved uniformity (p = 0.05 vs avg CTAC; p < 0.01 vs max CTAC). The results were supported with a pig study. CONCLUSIONS:Without MC, there was no significant difference between the three CTAC methods for measuring blood flow. With MC, the matched CTAC approach was significantly better, reducing the mean difference from truth by 6% in the simulated data and improving uniformity by 5%.

journal_name

Med Phys

journal_title

Medical physics

authors

Pourmoghaddas A,Klein R,deKemp RA,Wells RG

doi

10.1118/1.4788669

subject

Has Abstract

pub_date

2013-02-01 00:00:00

pages

022503

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • An optimization algorithm for intensity modulated radiotherapy--the simulated dynamics with dose-volume constraints.

    abstract::We have developed a new method for optimization in intensity modulated radiation therapy (IMRT) that makes use of simulated dynamics in a classical system of interacting particles. An analogy is drawn between intensity profile optimization in IMRT and relaxation to the equilibrium configuration in a dynamic system. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1528179

    authors: Hou Q,Wang J,Chen Y,Galvin JM

    更新日期:2003-01-01 00:00:00

  • A double mirror W/C multilayer monochromator for radiation biology applications.

    abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598259

    authors: MacKay JF,Pearson DW,Nelms BE,DeLuca PM Jr,Gould MN,Lagally MG

    更新日期:1998-05-01 00:00:00

  • Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model.

    abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12271

    authors: Abdoli M,Van Kranen SR,Stankovic U,Rossi MMG,Belderbos JSA,Sonke JJ

    更新日期:2017-07-01 00:00:00

  • Scatter transmission through an ideal grid.

    abstract::An analytic expression is derived for the transmission of isotropic scattered radiation incident upon an ideal parallel grid. It is found that the expression for the transmission usually found in the literature overestimates the transmission by approximately a factor of two. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594877

    authors: Siddon RL

    更新日期:1981-11-01 00:00:00

  • Differences in the lesion formation process between focused ultrasound and microwave ablations.

    abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2193689

    authors: Chen WS,Wu CC,Fang HY,Liu HL

    更新日期:2006-05-01 00:00:00

  • Obtaining S values for rectangular-solid tumors inside rectangular-solid host organs.

    abstract::A method is described for obtaining S values between a tumor and its host organ for use with the MIRD formalism. It applies the point-source specific absorbed fractions for an infinite water medium, tabulated by Berger, to a rectangular solid of arbitrary dimensions which contains a rectangular tumor of arbitrary dime...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596732

    authors: Stinchcomb TG,Durham JS,Fisher DR

    更新日期:1991-05-01 00:00:00

  • Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements.

    abstract:PURPOSE:The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966702

    authors: Chen Y,Chiu B

    更新日期:2016-12-01 00:00:00

  • A computer simulation of wavelet noise reduction in computed tomography.

    abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598654

    authors: Harpen MD

    更新日期:1999-08-01 00:00:00

  • On the conditioning of basis materials and its impact on multi-material decomposition based spectral imaging in photon-counting CT.

    abstract:PURPOSE:Material-specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy-integration or photon-counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14708

    authors: Tang X,Ren Y

    更新日期:2021-01-07 00:00:00

  • Automatic learning-based beam angle selection for thoracic IMRT.

    abstract:PURPOSE:The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908000

    authors: Amit G,Purdie TG,Levinshtein A,Hope AJ,Lindsay P,Marshall A,Jaffray DA,Pekar V

    更新日期:2015-04-01 00:00:00

  • Material elemental decomposition in dual and multi-energy CT via a sparsity-dictionary approach for proton stopping power ratio calculation.

    abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12796

    authors: Shen C,Li B,Chen L,Yang M,Lou Y,Jia X

    更新日期:2018-04-01 00:00:00

  • Technical Note: Impact of region of interest size and location in Gafchromic film dosimetry.

    abstract:PURPOSE:To evaluate dependence of measured dose on size and location of region of interest (ROI) in Gafchromic EBT3 film dosimetry. METHODS:Gafchromic EBT3 films were irradiated perpendicularly using the 6MV beam from a linear accelerator at 10 cm depth (100 cm SSD) of a 30 × 30 × 20 cm3 solid water phantom for a rang...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12885

    authors: Gholizadeh Sendani N,Karimian A,Ferreira C,Alaei P

    更新日期:2018-05-01 00:00:00

  • On the speckle-free nature of photoacoustic tomography.

    abstract:PURPOSE:A long-standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. METHODS:In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3187231

    authors: Guo Z,Li L,Wang LV

    更新日期:2009-09-01 00:00:00

  • Optimized knot placement for B-splines in deformable image registration.

    abstract:PURPOSE:To develop an automatic knot placement algorithm to enable the use of NonUniform Rational B-Splines (NURBS) in deformable image registration. METHODS:The authors developed a two-step approach to fit a known displacement vector field (DVF). An initial fit was made with uniform knot spacing. The error generated ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3609416

    authors: Jacobson TJ,Murphy MJ

    更新日期:2011-08-01 00:00:00

  • Library based x-ray scatter correction for dedicated cone beam breast CT.

    abstract:PURPOSE:The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4955121

    authors: Shi L,Vedantham S,Karellas A,Zhu L

    更新日期:2016-08-01 00:00:00

  • Tree structured wavelet transform segmentation of microcalcifications in digital mammography.

    abstract::A novel multistage algorithm is proposed for the automatic segmentation of microcalcification clusters (MCCs) in digital mammography. First, a previously reported tree structured nonlinear filter is proposed for suppressing image noise, while preserving image details, to potentially reduce the false positive (FP) dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597562

    authors: Qian W,Kallergi M,Clarke LP,Li HD,Venugopal P,Song D,Clark RA

    更新日期:1995-08-01 00:00:00

  • Experimental verification of a technique for predicting scattered radiation transfer: application to low photon energies.

    abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595807

    authors: Bernstein H,Muntz EP

    更新日期:1986-11-01 00:00:00

  • Statistical analysis of dose-volume and dose-wall histograms for rectal toxicity following 3D-CRT in prostate cancer.

    abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1951427

    authors: García-Vicente F,Zapatero A,Floriano A,Cruz-Conde A,Perez L,Marín A,Mínguez C,Torres JJ

    更新日期:2005-08-01 00:00:00

  • Model-based geometric calibration for medical x-ray systems.

    abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4931964

    authors: van der Maas R,de Jager B,Steinbuch M,Dries J

    更新日期:2015-11-01 00:00:00

  • The effect of angular spread on the intensity distribution of arbitrarily shaped electron beams.

    abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596252

    authors: Mohan R,Chui CS,Fontenla D,Han K,Ballon D

    更新日期:1988-03-01 00:00:00

  • Tumor volume measurement errors of RECIST studied with ellipsoids.

    abstract:PURPOSE:The authors investigate the extent to which Response Evaluation Criteria in Solid Tumors (RECIST) can predict tumor volumes in ideal geometric settings and using clinical data. METHODS:The authors consider a hierarchy of models including uniaxial ellipsoids, general ellipsoids, and composites of ellipsoids, us...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3577602

    authors: Levine ZH,Galloway BR,Peskin AP,Heussel CP,Chen JJ

    更新日期:2011-05-01 00:00:00

  • Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

    abstract:PURPOSE:The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides exce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914860

    authors: Yang Y,Wang KK,Eslami S,Iordachita II,Patterson MS,Wong JW

    更新日期:2015-04-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • Attention-aware fully convolutional neural network with convolutional long short-term memory network for ultrasound-based motion tracking.

    abstract:PURPOSE:One of the promising options for motion management in radiation therapy (RT) is the use of LINAC-compatible robotic-arm-mounted ultrasound imaging system due to its high soft tissue contrast, real-time capability, absence of ionizing radiation, and low cost. The purpose of this work is to develop a novel deep l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13510

    authors: Huang P,Yu G,Lu H,Liu D,Xing L,Yin Y,Kovalchuk N,Xing L,Li D

    更新日期:2019-05-01 00:00:00

  • Inter- and intra-software reproducibility of computed tomography lung density measurements.

    abstract:PURPOSE:Multiple commercial, open-source, and academic software tools exist for objective quantification of lung density in computed tomography (CT) images. The purpose of this study was to evaluate the intersoftware reproducibility of CT lung density measurements. METHODS:Computed tomography images from 50 participan...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14130

    authors: Kirby M,Hatt C,Obuchowski N,Humphries SM,Sieren J,Lynch DA,Fain SB,QIBA Lung Density Committee.

    更新日期:2020-07-01 00:00:00

  • Design and performance of a compact and stationary microSPECT system.

    abstract:PURPOSE:Over the last ten years, there has been an extensive growth in the development of microSPECT imagers. Most of the systems are based on the combination of conventional, relatively large gamma cameras with poor intrinsic spatial resolution and multipinhole collimators working in large magnification mode. Spatial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4822621

    authors: Van Holen R,Vandeghinste B,Deprez K,Vandenberghe S

    更新日期:2013-11-01 00:00:00

  • Correcting TG 119 confidence limits.

    abstract:PURPOSE:Task Group 119 (TG-119) has been adopted for evaluating the adequacy of intensity-modulated radiation therapy (IMRT) commissioning and for establishing patient-specific IMRT quality assurance (QA) passing criteria in clinical practice. TG-119 establishes 95% confidence limits (CLs), which help clinics identify ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12759

    authors: Kearney V,Solberg T,Jensen S,Cheung J,Chuang C,Valdes G

    更新日期:2018-03-01 00:00:00

  • Development of optical process for accessing three-dimensional patient topology.

    abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594447

    authors: Lerch IA,Barish RJ,Stern H

    更新日期:1978-11-01 00:00:00

  • Simulated accuracy assessment of small footprint body-mounted probe alignment device for MRI-guided cryotherapy of abdominal lesions.

    abstract:PURPOSE:Magnetic resonance imaging (MRI)-guided percutaneous cryotherapy of abdominal lesions, an established procedure, uses MRI to guide and monitor the cryoablation of lesions. Methods to precisely guide cryotherapy probes with a minimum amount of trial-and-error are yet to be established. To aid physicians in attai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14116

    authors: Shono N,Ninni B,King F,Kato T,Tokuda J,Fujimoto T,Tuncali K,Hata N

    更新日期:2020-06-01 00:00:00