Abstract:
PURPOSE:One of the promising options for motion management in radiation therapy (RT) is the use of LINAC-compatible robotic-arm-mounted ultrasound imaging system due to its high soft tissue contrast, real-time capability, absence of ionizing radiation, and low cost. The purpose of this work is to develop a novel deep learning-based real-time motion tracking strategy for ultrasound image-guided RT. METHODS:The proposed tracker combined the attention-aware fully convolutional neural network (FCNN) and the convolutional long short-term memory network (CLSTM) that is end-to-end trainable. The glimpse sensor module was built inside the attention-aware FCNN to discard majority of background by focusing on a region containing the object of interest. FCNN extracted discriminating spatial features of glimpse to facilitate temporal modeling for CLSTM. The saliency mask computed from CLSTM refined the features particular to the tracked landmarks. Moreover, the multitask loss strategy including bounding box loss, localization loss, saliency loss, and adaptive loss weighting term was utilized to facilitate training convergence and avoid over/underfitting. The tracker was tested on the databases provided by MICCAI 2015 challenges, and the ground truth data were obtained with the help of brute force-based template matching technology. RESULTS:The mean tracking error of 0.97 ± 0.52 mm and maximum tracking error of 1.94 mm were observed for 85 point landmarks across 39 ultrasound cases compared to the ground truth annotations. The tracking speed per frame per landmark with the GPU implementation ranged from 66 and 101 frames per second, which largely exceeded the ultrasound imaging rate. CONCLUSION:The results demonstrated the robustness and accuracy of the proposed deep learning-based motion estimation, despite the existence of some known shortcomings of ultrasound imaging such as speckle noise. The tracking speed of the system was found to be remarkable, sufficiently fast for real-time applications in RT environment. The approach provides a valuable tool to guide RT treatment with beam gating or multileaf collimator (MLC) tracking in real time.
journal_name
Med Physjournal_title
Medical physicsauthors
Huang P,Yu G,Lu H,Liu D,Xing L,Yin Y,Kovalchuk N,Xing L,Li Ddoi
10.1002/mp.13510subject
Has Abstractpub_date
2019-05-01 00:00:00pages
2275-2285issue
5eissn
0094-2405issn
2473-4209journal_volume
46pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The most common metric for comparing measured to calculated dose planes is a pass rate generated using percent difference, distance-to-agreement (DTA), or some combination of the two (e.g. gamma evaluation). The grid of analyzed points often corresponds to a dosimeter array with low areal-density of point detec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735070
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Two diodes which do not require correction factors for small field relative output measurements are designed and validated using experimental methodology. This was achieved by adding an air layer above the active volume of the diode detectors, which canceled out the increase in response of the diodes in small f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894728
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS:A comprehensive set of TPS commissioning and validation tests were developed using published guidelines. Nondosimetric validatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14740
更新日期:2021-01-28 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract:PURPOSE:A modular phantom for dosimetry and imaging performance evaluation in cone-beam computed tomography (CBCT) is reported, providing a tool for quantitative technical assessment that can be adapted to a broad variety of CBCT imaging configurations and clinical applications. METHODS:The phantom presents a set of m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13952
更新日期:2020-02-01 00:00:00
abstract::While simple, intravascular brachytherapy (IVB) presents a considerable potential for harm to the patient. The medical physicist maintains the responsibility to minimize the likelihood of operational problems or dosimetric errors. The principals for safe operation remain the same as with any radiotherapy treatment: to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1524167
更新日期:2002-12-01 00:00:00
abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14729
更新日期:2021-01-21 00:00:00
abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1800712
更新日期:2004-11-01 00:00:00
abstract::Transmission data for 4-MV bremsstrahlung beams have been measured with a combination of lead and aluminum attenuators. From these data, the original energy spectra have been reconstructed using an iterative least-squares technique, previously evaluated by simulation studies. The spectra on the central axis for three ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595356
更新日期:1983-11-01 00:00:00
abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598654
更新日期:1999-08-01 00:00:00
abstract:PURPOSE:To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS:In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actua...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4937780
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:The authors investigate the impact that incremental increases in the level of detail of patient-specific prior information have on image quality and the convergence behavior of an inversion algorithm in the context of near-field microwave breast imaging. A methodology is presented that uses image quality measur...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12585
更新日期:2017-12-01 00:00:00
abstract:PURPOSE:MR-guided radiation therapy (RT) offers unparalleled soft tissue contrast for localization and target tracking. However, MRI distortions may be detrimental to high precision RT. This work characterizes the gradient nonlinearity (GNL) and total distortions over the first year of clinical operation of a 0.35T MR-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13467
更新日期:2019-05-01 00:00:00
abstract:PURPOSE:We have developed a robust tool for performing volumetric and temporal analysis of nodules from respiratory gated four-dimensional (4D) CT. The method could prove useful in IMRT of lung cancer. METHODS:We modified the conventional graph-cuts method by adding an adaptive shape prior as well as motion informatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12690
更新日期:2018-01-01 00:00:00
abstract::This paper proposes a new respiratory gated radiation treatment system that allows real-time tumor localization while avoiding invasive operation to a patient. The proposed system employs a three-dimensional (3D) ultrasound device, a 3D digital localizer, and a real-time image processing system. At the planning time, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1634482
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939255
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate a surrogate-driven motion model based on four-dimensional computed tomography that is able to predict CT volumes corresponding to arbitrary respiratory phases. Furthermore, the comparison of three different driving surrogates is examined and the feasibility of using the mod...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12243
更新日期:2017-06-01 00:00:00
abstract::In the present investigation, the necessary tests for implementing a quality assurance program for a commercial treatment planning system (TPS), recently installed at Sao Paulo University School of Medicine Clinicas Hospital-Brazil, was established and performed in accordance with the new IAEA publication TRS 430, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2742779
更新日期:2007-07-01 00:00:00
abstract:PURPOSE:To develop a pencil beam dose calculation algorithm for scanned proton beams that improves modeling of scatter events. METHODS:Our pencil beam algorithm (PBA) was developed for calculating dose from monoenergetic, parallel proton beams in homogeneous media. Fermi-Eyges theory was implemented for pencil beam tr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735624
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. METHODS:Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Cov...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734916
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:One technical barrier to patient-specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient-specific multi-organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14131
更新日期:2020-06-01 00:00:00
abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948999
更新日期:2016-06-01 00:00:00
abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594156
更新日期:1975-01-01 00:00:00
abstract::Two experimental methods are described for obtaining average energies of neutron spectra produced by an electron accelerator in a medical treatment room. In the first method, the dose equivalent is measured by means of indium activation foils in an Andersson-Braun moderator. Fluences are determined by the usual activa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595662
更新日期:1985-11-01 00:00:00
abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13643
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:We present a simple, practical framework for truly 4D lung IMRT planning based on a weighted individual-phase optimization paradigm. This strategy is specifically developed for use in real-time tumor tracking delivery systems so as to utilize respiratory motion as an additional degree of freedom rather than a c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735644
更新日期:2012-06-01 00:00:00
abstract::The concept of the radiological depth is central to all algorithms which calculate radiation dose in a heterogeneous medium. For a discrete heterogeneous medium, consisting of regions of inhomogeneity, the radiological depth is usually presented as the sum over segments of the product of the segment length and the inh...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595739
更新日期:1985-01-01 00:00:00
abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3148834
更新日期:2009-07-01 00:00:00
abstract::The purposes of this research are to investigate the effectiveness of our novel image features for segmentation of anatomic regions such as the lungs and the mediastinum in chest radiographs and to develop an automatic computerized method for image processing. A total of 85 screening chest radiographs from Johns Hopki...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598277
更新日期:1998-06-01 00:00:00
abstract:PURPOSE:The purposes of this study is to measure the low frequency drop (LFD) of the modulation transfer function (MTF), associated with the long tails of the detector point spread function (PSF) of an on-board flat panel imager and study its impact on cone-beam CT (CBCT) image quality and scatter measurement accuracy....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4747260
更新日期:2012-09-01 00:00:00