Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.

Abstract:

PURPOSE:The purposes of this study is to measure the low frequency drop (LFD) of the modulation transfer function (MTF), associated with the long tails of the detector point spread function (PSF) of an on-board flat panel imager and study its impact on cone-beam CT (CBCT) image quality and scatter measurement accuracy. METHODS:Two different experimental methods were used to characterize LFD and its associated PSF of a Varian OBI flat-panel detector system: the edge response function (ERF) method and the disk transfer function (DTF) method. PSF was estimated by fitting parametric models to these measurements for four values of the applied voltage (kVp). The resultant PSF was used to demonstrate the effect of LFD on image contrast and CT number accuracy in CBCT images reconstructed from synthetic datasets, as well as, accuracy of scatter measurements with the beam-stop method. RESULTS:The MTFs derived from the measured ERF data revealed LFDs varying from 8% (at 60 kVp) to 10.5% (at 120 kVp), while the intensity of the long PSF tails was found to increase with increasing kVp. The veiling glare line spread functions derived from the ERF and DTF methods were in excellent agreement. Uncorrected veiling glare reduced contrast and the image intensity in CBCT reconstruction, near the phantom periphery (by 67 Hounsfield units in a 20 cm-in-diameter water phantom) and (to a smaller degree) near inhomogeneities. Use of the bow-tie filter mitigated these effects. Veiling glare also resulted in about 10%-15% overestimation of the scatter-to-primary ratio when measured with the beam-stop or beam-stop array method. CONCLUSIONS:The long tails of the detector PSF were found to have a modest dependence of beam spectrum, which is reflected on the MTF curve LFD. Our findings show that uncorrected veiling glare can affect quantitative accuracy and contrast in CBCT imaging, based on flat panel imager. In addition, it results in overestimation of the scatter-to-primary ratio, measured with the beam-stop methods.

journal_name

Med Phys

journal_title

Medical physics

authors

Lazos D,Williamson JF

doi

10.1118/1.4747260

subject

Has Abstract

pub_date

2012-09-01 00:00:00

pages

5639-51

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Evaluation of volumetric modulated arc therapy for cranial radiosurgery using multiple noncoplanar arcs.

    abstract:PURPOSE:To evaluate a commercial volumetric modulated arc therapy (VMAT), using multiple noncoplanar arcs, for linac-based cranial radiosurgery, as well as evaluate the combined accuracy of the VMAT dose calculations and delivery. METHODS:Twelve patients with cranial lesions of variable size (0.1-29 cc) and two multip...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3641874

    authors: Audet C,Poffenbarger BA,Chang P,Jackson PS,Lundahl RE,Ryu SI,Ray GR

    更新日期:2011-11-01 00:00:00

  • The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers.

    abstract::Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2042248

    authors: Rau AW,Bakueva L,Rowlands JA

    更新日期:2005-10-01 00:00:00

  • Mitigating differential baseline shifts in locally advanced lung cancer patients using an average anatomy model.

    abstract:BACKGROUND AND PURPOSE:Differential baseline shifts between primary tumor and involved lymph nodes in locally advanced lung cancer patients compromise the accuracy of radiotherapy. The purpose of this study was to evaluate the performance of an average anatomy model (AAM) derived from repeat imaging and deformable regi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12271

    authors: Abdoli M,Van Kranen SR,Stankovic U,Rossi MMG,Belderbos JSA,Sonke JJ

    更新日期:2017-07-01 00:00:00

  • Development and implementation of EPID-based quality assurance tests for the small animal radiation research platform (SARRP).

    abstract:PURPOSE:Although small animal image-guided radiotherapy (SA-IGRT) systems are used increasingly in preclinical research, tools for performing routine quality assurance (QA) have not been optimized and are not readily available. Robust, efficient, and reliable QA tools are needed to ensure the accuracy and reproducibili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12939

    authors: Anvari A,Poirier Y,Sawant A

    更新日期:2018-07-01 00:00:00

  • SU-E-J-63: Feasibility Study of Proton Digital Tomosynthesis in Proton Beam Therapy.

    abstract:PURPOSE:We investigated the feasibility of proton tomosynthesis as daily positioning of patients and compared the results with photon tomosynthesis as an alternative to conventional portal imaging or on-board cone-beam computed tomography. METHODS:Dedicated photon-like proton beam using the passively scattered proton ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734898

    authors: Min B,Kwak J,Lee J,Cho S,Park S,Yoo S,Chung K,Cho S,Lim Y,Shin D,Lee S,Kim J

    更新日期:2012-06-01 00:00:00

  • Dosimetric verification of helical tomotherapy for total scalp irradiation.

    abstract::Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2996288

    authors: Hardcastle N,Soisson E,Metcalfe P,Rosenfeld AB,Tome WA

    更新日期:2008-11-01 00:00:00

  • Simple design for a Styrofoam cutter.

    abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594206

    authors: Sorensen A,Goshaw L

    更新日期:1975-11-01 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • An empirical model for independent dose verification of the Gamma Knife treatment planning.

    abstract::A formalism for an independent dose verification of the Gamma Knife treatment planning is developed. It is based on the approximation that isodose distribution for a single shot is in the shape of an ellipsoid in three-dimensional space. The dose profiles for a phantom along each of the three major axes are fitted to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1501139

    authors: Phaisangittisakul N,Ma L

    更新日期:2002-09-01 00:00:00

  • Estimation of the axial wall strains induced by an arterial stenosis at peak flow.

    abstract::In the last 30 years, thousands of basic or clinical studies have been devoted to atherosclerosis or to the problem of restenosis after angioplasty. In these studies, axial stresses in the vessel wall have received practically no attention, contrary to circumferential stress and purely biological aspects. Based on a r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1844432

    authors: Doriot PA,Dorsaz PA

    更新日期:2005-02-01 00:00:00

  • Surface dose rate calibration of Sr-90 plane ophthalmic applicators.

    abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596702

    authors: Goetsch SJ,Sunderland KS

    更新日期:1991-03-01 00:00:00

  • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.

    abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3177312

    authors: Van Holen R,Staelens S,Vandenberghe S

    更新日期:2009-09-01 00:00:00

  • Dependence of virtual wedge factor on dose calibration and monitor units.

    abstract::One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344204

    authors: Zhu XR,Gillin MT,Ehlers K,Lopez F,Grimm DF,Rownd JJ,Steinberg TH

    更新日期:2001-02-01 00:00:00

  • Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

    abstract:PURPOSE:The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773866

    authors: Lauzier PT,Chen GH

    更新日期:2013-02-01 00:00:00

  • Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom.

    abstract:PURPOSE:Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCT...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4870956

    authors: Moyers MF

    更新日期:2014-06-01 00:00:00

  • A 3D ultrasound scanning system for image guided liver interventions.

    abstract:PURPOSE:Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional liver procedures; however, 2D US lacks volumetric information that may benefit interventional procedures. Over the past decade, three-dimensional ultrasound (3D US) has been developed to prov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4824326

    authors: Neshat H,Cool DW,Barker K,Gardi L,Kakani N,Fenster A

    更新日期:2013-11-01 00:00:00

  • Automatic detection of simulated motion blur in mammograms.

    abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14069

    authors: Kamona N,Loew M

    更新日期:2020-04-01 00:00:00

  • Structure and adaptation of arteries to pulsatile flow: the case of the ascending aorta.

    abstract:PURPOSE:The objectives are: (i) assess the development of the impedance of some arteries during the first decades of life; (ii) determine the influence of pulse rate in arterial impedance; (iii) compare the structure of some arterial segments with optimized structures with respect to blood flow; and (iv) explain the el...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4876379

    authors: Silva C,Reis AH

    更新日期:2014-06-01 00:00:00

  • Evaluations of magnetic resonance imaging parameters with simple phantoms.

    abstract::Imaging parameters associated with a clinical magnetic resonance imaging (MRI) system, evaluated with the use of simple and inexpensive phantoms, are described in evaluation of a clinical MRI system. Images, obtained with a Diasonics 0.35-T MRI system using an elliptical whole-body radio frequency coil, are presented ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595894

    authors: Brateman L,Jennings LW,Nunnally RL,Vaughan JT

    更新日期:1986-07-01 00:00:00

  • Compartment modeling of dynamic brain PET--the impact of scatter corrections on parameter errors.

    abstract:PURPOSE:The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897610

    authors: Häggström I,Schmidtlein CR,Karlsson M,Larsson A

    更新日期:2014-11-01 00:00:00

  • Anniversary paper: Role of medical physicists and the AAPM in improving geometric aspects of treatment accuracy and precision.

    abstract::The last 50 years have seen great advances in the accuracy of external beam radiation therapy. Geometrical uncertainties have been reduced from a centimeter or more in presimulation, skin-mark guided days to 1-2 mm in today's image-guided radiation therapy treatments. Medical physicists, with the support and guidance ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2836420

    authors: Yorke ED,Keall P,Verhaegen F

    更新日期:2008-03-01 00:00:00

  • The tracks of the Compton effect.

    abstract::The observation of scattered radiations of larger wavelength than the primary had been repeatedly rejected or explained away by many researchers, including Compton. After years of vacillations, he recognized the effect named after him and was the first to develop a quantal equation predicting the wavelength of scatter...

    journal_title:Medical physics

    pub_type: 传,历史文章,杂志文章

    doi:10.1118/1.595046

    authors: del Regato JA

    更新日期:1981-11-01 00:00:00

  • MR acoustic radiation force imaging: in vivo comparison to ultrasound motion tracking.

    abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3120289

    authors: Huang Y,Curiel L,Kukic A,Plewes DB,Chopra R,Hynynen K

    更新日期:2009-06-01 00:00:00

  • Linear motion correction in three dimensions applied to dynamic gadolinium enhanced breast imaging.

    abstract::Quantitative analysis of dynamic gadolinium-DTPA (diethylenetriamine pentaacetic acid) enhanced magnetic resonance imaging (MRI) is emerging as a highly sensitive tool for detecting malignant breast tissue. Three-dimensional rapid imaging techniques, such as keyhole MRI, yield high temporal sampling rates to accuratel...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598576

    authors: Krishnan S,Chenevert TL,Helvie MA,Londy FL

    更新日期:1999-05-01 00:00:00

  • X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

    abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597688

    authors: Fahrig R,Rowlands JA,Yaffe MJ

    更新日期:1996-04-01 00:00:00

  • The use of a diode matrix in commissioning activities for electron energies > or = 9 MeV: a feasibility study.

    abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3081414

    authors: Borca VC,Pasquino M,Ozzello F,Tofani S

    更新日期:2009-04-01 00:00:00

  • Technical Note: Study of the electron transport parameters used in PENELOPE for the Monte Carlo simulation of Linac targets.

    abstract:PURPOSE:The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron step length. In the PENELOPE code, the step length is partially determined by the transport parameters...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916686

    authors: Rodriguez M,Sempau J,Brualla L

    更新日期:2015-06-01 00:00:00

  • A Monte Carlo investigation of low-Z target image quality generated in a linear accelerator using Varian's VirtuaLinac.

    abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4861818

    authors: Parsons D,Robar JL,Sawkey D

    更新日期:2014-02-01 00:00:00

  • Laser heating of thermoluminescent plates: application to intraoperative radiotherapy.

    abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597725

    authors: Beteille D,Setzkom R,Prévost H,Dusseau L,Fesquet J,Gasiot J,Muraro S,Delard R,Dubois JB,Ailleres N,Missous O

    更新日期:1996-08-01 00:00:00

  • Image reconstruction for positron emission tomography based on patch-based regularization and dictionary learning.

    abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13804

    authors: Zhang W,Gao J,Yang Y,Liang D,Liu X,Zheng H,Hu Z

    更新日期:2019-11-01 00:00:00