Abstract:
:The concept of the radiological depth is central to all algorithms which calculate radiation dose in a heterogeneous medium. For a discrete heterogeneous medium, consisting of regions of inhomogeneity, the radiological depth is usually presented as the sum over segments of the product of the segment length and the inhomogeneity density of the region corresponding to the segment. This paper illustrates that the usual formulation is inefficient because it requires the solution of the topological problem of which region corresponds to each segment. For simple heterogeneity problems involving just three regions of inhomogeneity, it is found that the topological problem constitutes at least 85% of the time required to calculate the radiological depth. It is shown in this paper that formulating the radiological depth as a sum over regions rather than as a sum over segments allows one to avoid this topological problem entirely.
journal_name
Med Physjournal_title
Medical physicsauthors
Siddon RLdoi
10.1118/1.595739subject
Has Abstractpub_date
1985-01-01 00:00:00pages
84-7issue
1eissn
0094-2405issn
2473-4209journal_volume
12pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:The purpose of this study is to investigate some characteristics of the beam delivery system and their effects on the dose distribution of intensity-modulated radiation therapy (IMRT) and the results of patient-specific IMRT quality assurance (QA). These characteristics include the accelerator source distributi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3413997
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:Development and verification of peak signal-to-noise ratio (SNR(P)) equations for determining optimum CT scanning and scoring parameters for a new automated coronary calcium scoring program (N-vivo). Experimental evaluation of the new program for scoring small calcium hydroxyapatite (CaHA) microspheres with sma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3442276
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:Many clinical applications depend critically on the accurate differentiation and classification of different types of materials in patient anatomy. This work introduces a unified framework for accurate nonlinear material decomposition and applies it, for the first time, in the concept of triple-energy CT (TECT)...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12933
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:Dedicated breast PET/CT is expected to have utility in local staging, surgical planning, monitoring of therapy response, and detection of residual disease for breast cancer. Quantitative metrics will be integral to several such applications. The authors present a validation of fully 3D data correction schemes f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3703593
更新日期:2012-05-01 00:00:00
abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594960
更新日期:1981-05-01 00:00:00
abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767763
更新日期:2012-12-01 00:00:00
abstract::The visual observer performance for detecting low-contrast patterns by employing both the receiver operating characteristic (ROC) and the 9-alternative forced choice (9-AFC) method is investigated. For each observer and each experimental technique, the results were reproducible with respect to a repeated observation. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596986
更新日期:1993-05-01 00:00:00
abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735656
更新日期:2012-06-01 00:00:00
abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594206
更新日期:1975-11-01 00:00:00
abstract::The customization of brachytherapy dose distributions for gynecologic malignancies is limited by the spatial positioning of the applicators. We tested the hypothesis that applicator-guided intensity modulated radiation therapy (AGIMRT) has the potential to deliver highly conformal dose distributions to cervical tumors...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.1645678
更新日期:2004-04-01 00:00:00
abstract::A computer program was implemented to predict mammography x-ray beam parameters in the range 20-40 kV for Mo/Mo, Mo/Rh, Rh/Rh, and W/Al target/filter combinations. The computation method used to simulate mammography x-ray spectra is based on the Boone et al. model. The beam quality parameters such as the half-value la...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1608498
更新日期:2003-10-01 00:00:00
abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3456598
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techni...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897242
更新日期:2014-11-01 00:00:00
abstract::In this paper we examine the few-view reconstruction problem as it applies to imaging vascular trees. A fully automated reconstruction algorithm is described that circumvents the traditional "correspondence problem," using only notions of consistency and connectivity. It is assumed that the vascular tree is a connecte...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597704
更新日期:1996-02-01 00:00:00
abstract::The increasing complexity of modern radiation therapy planning and delivery challenges traditional prescriptive quality management (QM) methods, such as many of those included in guidelines published by organizations such as the AAPM, ASTRO, ACR, ESTRO, and IAEA. These prescriptive guidelines have traditionally focuse...
journal_title:Medical physics
pub_type: 共识发展会议,杂志文章,实务指引
doi:10.1118/1.4947547
更新日期:2016-07-01 00:00:00
abstract::The minimum margins required to compensate for random geometric uncertainties in the delivery of radiotherapy treatment were determined for a spherical Clinical Target Volume, using an analytic model for the cumulative dose. Margins were calculated such that the minimum dose in the target would be no less than 95% of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1809991
更新日期:2004-11-01 00:00:00
abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740105
更新日期:2012-07-01 00:00:00
abstract::The verification of dose distributions with high dose gradients as appearing in brachytherapy or stereotactic radiotherapy for example, calls for dosimetric methods with sufficiently high spatial resolution. Polymer gels in combination with a MR or optical scanner as a readout device have the potential of performing t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2898173
更新日期:2008-05-01 00:00:00
abstract::A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2360014
更新日期:2006-11-01 00:00:00
abstract::In order to use negative pions for the treatment of large deep-seated tumors in radiotherapy, it is necessary to produce depth-dose distributions tailored to specific shapes. We present here a method of beam shaping which utilizes a fluid-filled piston having a programmable, computer-controlled, time-dependent thickne...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594313
更新日期:1977-09-01 00:00:00
abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13255
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12899
更新日期:2018-06-01 00:00:00
abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12064
更新日期:2017-02-01 00:00:00
abstract::The wall of an ionization chamber is commonly assumed to have a negligible effect on chamber response in electron beams. For cylindrical chambers with thin walls this assumption is valid. However, parallel-plate chambers commonly possess large mechanical supports which may affect chamber response in a manner not accou...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596165
更新日期:1988-01-01 00:00:00
abstract:PURPOSE:For the purpose of size-specific dose estimation, information regarding patient attenuation is required. The purpose of this work is to describe a method for measuring patient attenuation and expressing the results in terms of a water cylinder, with cross sectional area A(w), which would absorb the same average...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4754303
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:One limitation of positron emission tomography (PET) imaging of the torso is patient motion. Motion-compensated image reconstruction (MCIR) is one method employed to reduce the deleterious effects of motion. Existing MCIR algorithms use a single sensitivity correction term, which provides inexact normalization ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3611041
更新日期:2011-09-01 00:00:00
abstract::Magnetic beam scanning allows one to spread proton beam over the desired radiation field area, improving beam utilization and conformity to the target area. This article discusses generic scan forms for generating uniform circular and rectangular fields and establishes criteria that can be applied to optimize selected...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3158731
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:Current respiratory motion monitoring devices used for motion synchronization in medical imaging and radiotherapy provide either 1D respiratory signal over a specific region or 3D information based on few external or internal markers. On the other hand, newer technology may offer the potential to monitor the en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589131
更新日期:2011-06-01 00:00:00
abstract::Highly focused dose distributions for radiosurgery applications are successfully achieved using either multiple static high-energy particle beams or multiple-arc circular x-ray beams from a linac. It has been suggested that conformal x-ray techniques using dynamically shaped beams with a moving radiation source would ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597654
更新日期:1995-12-01 00:00:00
abstract::The scattered-photon part of pencil-beam dose kernels for high-energy x-ray beams can be derived experimentally by differentiating the broad-beam scatter-to-primary dose ratio as a function of radius. Formally, this requires a uniform and parallel beam, and the procedure is complicated by the nonideal, actual beam con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597884
更新日期:1996-09-01 00:00:00