Abstract:
:In this paper we examine the few-view reconstruction problem as it applies to imaging vascular trees. A fully automated reconstruction algorithm is described that circumvents the traditional "correspondence problem," using only notions of consistency and connectivity. It is assumed that the vascular tree is a connected structure and that its centerlines have been identified in three or more images. The first of three steps in the procedure involves generating a connected structure that represents the multiplicity of solutions that are consistent with any two (different) projections. The second step assigns to each branch in this structure a measure of agreement based on its relationship with one or more additional views of the vasculature. The problem then becomes one of propagating this information, via connectivity relationships and consistency checks, throughout the above structure to distinguish between the branches comprising the imaged structure and the accompanying artifacts. In this paper we present the theory and methodology of the technique, while in a companion paper we address the issue of validation via simulations and experiments. Together, these papers shed some light on why ambiguities arise and often lead to errors in the few-view reconstruction problem. Strategies to handle these errors are described and results are presented that demonstrate the ability to obtain adequate reconstructions with as few as three distinct views.
journal_name
Med Physjournal_title
Medical physicsauthors
Henri CJ,Peters TMdoi
10.1118/1.597704subject
Has Abstractpub_date
1996-02-01 00:00:00pages
197-204issue
2eissn
0094-2405issn
2473-4209journal_volume
23pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-S...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2937652
更新日期:2008-07-01 00:00:00
abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3168554
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4704496
更新日期:2012-05-01 00:00:00
abstract::Like Medical Physics, Imaging Informatics encompasses concepts touching every aspect of the imaging chain from image creation, acquisition, management and archival, to image processing, analysis, display and interpretation. The two disciplines are in fact quite complementary, with similar goals to improve the quality ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735777
更新日期:2012-06-01 00:00:00
abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3097633
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techni...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897242
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with Ga...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735542
更新日期:2012-06-01 00:00:00
abstract::A simple modification is presented for two commercially available hyperthermia applicators which dramatically improves the regulation and dynamic control of the temperature at the bolus/tissue interface. This alteration requires the addition of a variable speed pump, bubble trap, simple heat exchanger, and a few minor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597196
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:To investigate a novel locally adaptive projection space denoising algorithm for low-dose CT data. METHODS:The denoising algorithm is based on bilateral filtering, which smooths values using a weighted average in a local neighborhood, with weights determined according to both spatial proximity and intensity si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3232004
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4966027
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939663
更新日期:2016-02-01 00:00:00
abstract::Modern computed tomography (CT) scanners use cone-beam configurations for increasing volume coverage, improving x-ray-tube utilization, and yielding isotropic spatial resolution. Recently, there have been significant developments in theory and algorithms for exact image reconstruction from cone-beam projections. In pa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2337270
更新日期:2006-10-01 00:00:00
abstract::The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy dose calculations. We used the EGS4/BEAM code to obtain the phase-space data for 6-20 MeV electron beams and 4, 6, and 15 MV photon beams for Varian Clinac 1800, 2100C, and 2300CD accelerators. A multiple-source model was used ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598729
更新日期:1999-10-01 00:00:00
abstract::The MCNP Monte Carlo radiation transport code was modified for diagnostic medical physics applications. In particular, the modified code was thoroughly benchmarked for the production of polychromatic tungsten x-ray spectra in the 30-150 kV range. Validating the modified code for coupled electron-photon transport with ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1288397
更新日期:2000-12-01 00:00:00
abstract:PURPOSE:The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4916802
更新日期:2015-05-01 00:00:00
abstract::Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved ...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935869
更新日期:2015-12-01 00:00:00
abstract::Approximately 70-85% of breast biopsies are performed on benign lesions. To reduce this high number of biopsies performed on benign lesions, a case-based reasoning (CBR) classifier was developed to predict biopsy results from BI-RADS findings. We used 1433 (931 benign) biopsy-proven mammographic cases. CBR similarity ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1501140
更新日期:2002-09-01 00:00:00
abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595546
更新日期:1984-09-01 00:00:00
abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.596616
更新日期:1991-11-01 00:00:00
abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3036117
更新日期:2009-01-01 00:00:00
abstract::Many papers discussed the I value for water given by the ICRU, concluding that a value of about 80 +/- 2 eV instead of 67.2 eV would reproduce measured ion depth-dose curves. A change in the I value for water would have an effect on the stopping power and, hence, on the water-to-air stopping power ratio, which is impo...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3085877
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:In this report, the authors introduce the general concept of the completeness map, as a means to evaluate the completeness of data acquired by a given CT system design (architecture and scan mode). They illustrate the utility of completeness map by applying the completeness map concept to a number of candidate ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3700172
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897382
更新日期:2014-11-01 00:00:00
abstract:PURPOSE:The most common metric for comparing measured to calculated dose planes is a pass rate generated using percent difference, distance-to-agreement (DTA), or some combination of the two (e.g. gamma evaluation). The grid of analyzed points often corresponds to a dosimeter array with low areal-density of point detec...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735070
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:A new technique called "curvilinear approach" for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. METHODS:Twenty LDR prostate brachytherapy cases planned intraopera...
journal_title:Medical physics
pub_type: 杂志文章,随机对照试验
doi:10.1118/1.3694110
更新日期:2012-04-01 00:00:00
abstract:PURPOSE:The need for four-dimensional (4D) treatment planning becomes indispensable when it comes to radiation therapy for moving tumors in the thoracic and abdominal regions. The primary purpose of this study is to combine the actual breathing trace during each individual treatment fraction with the Linac's log file i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13579
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation-free area. METHODS:Optimized ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12914
更新日期:2018-06-01 00:00:00
abstract::With the increased sophistication of lasers used for patient positioning in radiotherapy comes increased possibilities for mistakes in installing the lasers, which can result in serious patient positioning errors. Two principles must be followed when mounting cross-projecting lasers: (1) the horizontal line must be on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594960
更新日期:1981-05-01 00:00:00
abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598743
更新日期:1999-11-01 00:00:00
abstract::Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598598
更新日期:1999-05-01 00:00:00