Chord-based image reconstruction in cone-beam CT with a curved detector.

Abstract:

:Modern computed tomography (CT) scanners use cone-beam configurations for increasing volume coverage, improving x-ray-tube utilization, and yielding isotropic spatial resolution. Recently, there have been significant developments in theory and algorithms for exact image reconstruction from cone-beam projections. In particular, algorithms have been proposed for image reconstruction on chords; and advantages over the existing algorithms offered by the chord-based algorithms include the high flexibility of exact image reconstruction for general scanning trajectories and the capability of exact reconstruction of images within a region of interest from truncated data. These chord-based algorithms have been developed only for flat-panel detectors. Many cone-beam CT scanners employ curved detectors for important practical considerations. Therefore, in this work, we have derived chord-based algorithms for a curved detector so that they can be applied to reconstructing images directly from data acquired by use of a CT scanner with a curved detector. We have also conducted preliminary numerical studies to demonstrate and evaluate the reconstruction properties of the derived chord-based algorithms for curved detectors.

journal_name

Med Phys

journal_title

Medical physics

authors

Zuo N,Xia D,Zou Y,Jiang T,Pan XC

doi

10.1118/1.2337270

subject

Has Abstract

pub_date

2006-10-01 00:00:00

pages

3743-57

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

33

pub_type

杂志文章
  • The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach.

    abstract::The verification of dose distributions with high dose gradients as appearing in brachytherapy or stereotactic radiotherapy for example, calls for dosimetric methods with sufficiently high spatial resolution. Polymer gels in combination with a MR or optical scanner as a readout device have the potential of performing t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2898173

    authors: Bayreder C,Schön R,Wieland M,Georg D,Moser E,Berg A

    更新日期:2008-05-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • Segmentation of the prostate from suprapubic ultrasound images.

    abstract::We present a technique for semiautomated segmentation of human prostates using suprapubic ultrasound (US) images. In this approach, a speckle reducing anisotropic diffusion (SRAD) is applied to enhance the images and the instantaneous coefficient of variation (ICOV) is utilized for edge detection. Segmentation is acco...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1809791

    authors: Yu Y,Molloy JA,Acton ST

    更新日期:2004-12-01 00:00:00

  • Design and evaluation of a HDR skin applicator with flattening filter.

    abstract::The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2825622

    authors: Granero D,Pérez-Calatayud J,Gimeno J,Ballester F,Casal E,Crispín V,van der Laarse R

    更新日期:2008-02-01 00:00:00

  • Investigation of effective decision criteria for multiobjective optimization in IMRT.

    abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3589128

    authors: Holdsworth C,Stewart RD,Kim M,Liao J,Phillips MH

    更新日期:2011-06-01 00:00:00

  • SU-E-I-32: Sterile Radiation Reduction Gloves May Be Contraindicated in Fluoroscopically Guided Interventions.

    abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734747

    authors: Pasciak A,Neveu M,Sriharan A,Balius A,Jones A

    更新日期:2012-06-01 00:00:00

  • An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones.

    abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517613

    authors: Arnold ML,McNeill FE,Stronach IM,Pejovic-Milic A,Chettle DR,Waker A

    更新日期:2002-11-01 00:00:00

  • Determination of the half-life of I-125 encapsulated clinical seeds using a Si(Li) detector.

    abstract::The half-life of two I-125 encapsulated clinical seeds was measured with a Si(Li) semiconductor detector. Two measurements of each seed yielded an average half-life of 59.56 +/- 0.17 days. The results are discussed in terms of the influence of possible I-126 contamination and leakage of I-125 activity through encapsul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595423

    authors: Kubo H

    更新日期:1983-11-01 00:00:00

  • Age-dependent dose calculations for common PET radionuclides and brain radiotracers in nonhuman primate computational models.

    abstract:PURPOSE:The combination of nonhuman primates (NHPs) with the state-of-the-art molecular imaging technologies allows for within-subject longitudinal research aiming at gaining new insights into human normal and disease conditions and provides an ideal foundation for future translational studies of new diagnostic tools, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14333

    authors: Xie T,Chen X,Zaidi H

    更新日期:2020-09-01 00:00:00

  • Experimental test of theoretical models for time-resolved reflectance.

    abstract::Four different expressions, derived from the diffusion theory or the random walk model, were used to fit time-resolved reflectance data for the evaluation of tissue optical properties. The experimental reflectance curves were obtained from phantoms of known optical parameters (absorption and transport scattering coeff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597739

    authors: Cubeddu R,Pifferi A,Taroni P,Torricelli A,Valentini G

    更新日期:1996-09-01 00:00:00

  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Determining the energy spectrum of clinical linear accelerator using an optimized photon beam transmission protocol.

    abstract:PURPOSE:The complex beam delivery techniques for patient treatment using a clinical linear accelerator (linac) may result in variations in the photon spectra, which can lead to dosimetric differences in patients that cannot be accounted for by current treatment planning systems (TPSs). Therefore, precise knowledge of t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13569

    authors: Choi HJ,Park H,Yi CY,Kim BC,Shin WG,Min CH

    更新日期:2019-07-01 00:00:00

  • A unified material decomposition framework for quantitative dual- and triple-energy CT imaging.

    abstract:PURPOSE:Many clinical applications depend critically on the accurate differentiation and classification of different types of materials in patient anatomy. This work introduces a unified framework for accurate nonlinear material decomposition and applies it, for the first time, in the concept of triple-energy CT (TECT)...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12933

    authors: Zhao W,Vernekohl D,Han F,Han B,Peng H,Yang Y,Xing L,Min JK

    更新日期:2018-07-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • Application of the TRS 483 code of practice for reference and relative dosimetry in tomotherapy.

    abstract:PURPOSE:To apply the recent code of practice from the IAEA/AAPM, TRS 483, to helical tomotherapy (HT) for reference and relative dosimetry obtaining correction factors for the Exradin A1SL ionization chamber. METHODS:The beam quality correction factor for the A1SL chamber was obtained through three different approache...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13855

    authors: Lopes MDC,Santos T,Ventura T,Capela M

    更新日期:2019-12-01 00:00:00

  • SU-E-T-504: Incident Fluence Reconstruction Based on Monte Carlo Finite-Size Pencil Beam Model for Dose Guided Radiation Therapy.

    abstract:PURPOSE:In dose guided radiation therapy, incident fluence is one of the important parameters for both influence verification and dose reconstruction. The objective of this investigation was to develop a method to obtain the incident fluence for dose reconstruction in dose guided radiation therapy (DGRT). METHODS:An i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735593

    authors: Li G,Wu Y,FDS Team.

    更新日期:2012-06-01 00:00:00

  • Microdosimetric study for secondary neutrons in phantom produced by a 290 MeV/nucleon carbon beam.

    abstract::Absorbed doses from main charged-particle beams and charged-particle fragments have been measured with high accuracy for particle therapy, but there are few reports for doses from neutron components produced as fragments. This study describes the measurements on neutron doses produced by carbon beams; microdosimetric ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2767933

    authors: Endo S,Tanaka K,Takada M,Onizuka Y,Miyahara N,Sato T,Ishikawa M,Maeda N,Hayabuchi N,Shizuma K,Hoshi M

    更新日期:2007-09-01 00:00:00

  • Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator.

    abstract::Charge coupled devices (CCDs) are being increasingly used in radiation therapy for dosimetric purposes. However, CCDs are sensitive to stray radiation. This effect induces transient noise. Radiation-induced noise strongly alters the image and therefore limits its quantitative analysis. The purpose of this work is to c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2975147

    authors: Archambault L,Briere TM,Beddar S

    更新日期:2008-10-01 00:00:00

  • Performance evaluation of a diode array for enhanced dynamic wedge dosimetry.

    abstract::The performance of a diode array (Profiler) was evaluated by comparing its enhanced dynamic wedge (EDW) profiles measured at various depths with point measurements using a 0.03 cm3 ionization chamber on a commercial linear accelerator. The Profiler, which covers a 22.5 cm width, was used to measure larger field widths...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598019

    authors: Zhu TC,Ding L,Liu CR,Palta JR,Simon WE,Shi J

    更新日期:1997-07-01 00:00:00

  • SU-E-T-145: MRI Gel Dosimetry Applied to Dose Profile Determination for 50kV X-Ray Tube.

    abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735203

    authors: Schwarcke M,Marques T,Nicolucci P,Filho OB

    更新日期:2012-06-01 00:00:00

  • A new framework of image reconstruction from fan beam projections.

    abstract::In this paper, we present a unified framework to reconstruct images for both fan beam and cone beam projections. The important feature of our theoretical framework is that it does not depend on the classical concept of the Radon transform at all. This property allows us to directly generalize the ideas and techniques ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1577252

    authors: Chen GH

    更新日期:2003-06-01 00:00:00

  • Investigation of gamma knife image registration errors resulting from misalignment between the patient and the imaging axis.

    abstract::The ability of Leksell GammaPlan to perform stereotactic space localizations with image sets where there is misalignment of the patient's head (stereotactic frame and fiducial apparatus) relative to the computed tomography (CT) scanner coordinate system was studied. Misalignment is sometimes necessary for patient comf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2179751

    authors: Cernica G,Wang Z,Malhotra H,de Boer S,Podgorsak MB

    更新日期:2006-04-01 00:00:00

  • Large field of view distortion assessment in a low-field MR-linac.

    abstract:PURPOSE:MR-guided radiation therapy (RT) offers unparalleled soft tissue contrast for localization and target tracking. However, MRI distortions may be detrimental to high precision RT. This work characterizes the gradient nonlinearity (GNL) and total distortions over the first year of clinical operation of a 0.35T MR-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13467

    authors: Nejad-Davarani SP,Kim JP,Du D,Glide-Hurst C

    更新日期:2019-05-01 00:00:00

  • A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods.

    abstract:PURPOSE:Respiratory gating in PET is an approach used to minimize the negative effects of respiratory motion on spatial resolution. It is based on an initial determination of a patient's respiratory movements during a scan, typically using hardware based systems. In recent years, several fully automated databased algor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3483784

    authors: Kesner AL,Kuntner C

    更新日期:2010-10-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • SU-E-T-228: The Beauty and the Beast: Transition from Film/paper Charts to Paperless Environment with a New TrueBeam/ARIA System in a Small Community Hospital on a Tight Budget.

    abstract:PURPOSE:To review the issues a physicist may encounter in a community hospital during the transition from film/paper charts to a paperless environment with ARIA and a TrueBeam LINAC. With a lean budget, it was necessary for the physics group to take on the project management responsibilities in order save costs. This w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735291

    authors: Chu K,Rasmussen B

    更新日期:2012-06-01 00:00:00

  • SU-D-BRCD-02: A Novel Cylindrical 3D Water Scanner for Beam Data Collection: I. Validation of the Automatic-Setup.

    abstract:PURPOSE:To determine the accuracy and reproducibility of the automatic- setup procedure of a 3D water scanner (3D SCANNER, Sun Nuclear Corp). The procedure automatically aligns the scanner's coordinate system to the Linac coordinate system. A unique off-center detector holder extends the scan range to 630 mm, eliminati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734668

    authors: Li J,Lu B,Yan G,Huang Y,Liu C

    更新日期:2012-06-01 00:00:00

  • Penetration quality measurement for standardization of radiographic image quality.

    abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594156

    authors: Lin PJ

    更新日期:1975-01-01 00:00:00

  • Are we doing any good by doing really well? (Where's the Bacon?).

    abstract::Francis Bacon, who with Rene Decartes laid the intellectual foundations for Western science in the seventeenth century, asserted that the purpose of all knowledge is "action in the production of works for ... the relief of man's estate." We assess briefly several aspects of a few of the current efforts directed to the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1555493

    authors: Herbert D

    更新日期:2003-04-01 00:00:00

  • Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck.

    abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4830427

    authors: Yan M,Lovelock D,Hunt M,Mechalakos J,Hu Y,Pham H,Jackson A

    更新日期:2013-12-01 00:00:00