Abstract:
:In this paper, we present a unified framework to reconstruct images for both fan beam and cone beam projections. The important feature of our theoretical framework is that it does not depend on the classical concept of the Radon transform at all. This property allows us to directly generalize the ideas and techniques developed in this paper to the cone beam reconstruction problem. In this paper, we extract such a framework from developing a new image reconstruction scheme from fan beam projections. Our new scheme also provides us new understanding of fan beam reconstruction problem. Our main results for the fan beam reconstruction are the following: First, we derive a general reconstruction scheme, in which the data sufficiency condition is transparently revealed by the reconstruction formula. Specifically, the data sufficiency condition for an accurate reconstruction of a region of interest (ROI) is that all the lines passing through the ROI must intersect the source trajectory at least once. Second, we further simplify the general reconstruction scheme by following three major steps of our new framework: (i) using symmetries of intermediate function; (ii) handling the data redundancy; (iii) changing discrete summation over the possible focal points into an integral along the source trajectory. After these steps, we obtain a new filtered backprojection algorithm. The key characteristic of this new algorithm is to take derivative of measured data with respect to the trajectory parameter. In practice, we can trade this derivative to some other continuous functions. In the configuration of a circular source trajectory with a third generation arc/collinear detector, we demonstrate how to remove the undesirable derivative of measured projection data. It results in a new algorithm for the sequential reconstruction of a ROI with a general normalized weighting function.
journal_name
Med Physjournal_title
Medical physicsauthors
Chen GHdoi
10.1118/1.1577252subject
Has Abstractpub_date
2003-06-01 00:00:00pages
1151-61issue
6eissn
0094-2405issn
2473-4209journal_volume
30pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::During the past decade the use of undersampled acquisition and constrained reconstruction have led to significant increases in data acquisition speed, SNR, spatial resolution and temporal resolution in MR imaging. When a separately acquired constraining image is combined with an angiographic time series the traditiona...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735797
更新日期:2012-06-01 00:00:00
abstract::Three-dimensional water phantoms are routinely used when acquiring the data necessary to commission medical linear accelerators. A new water phantom controller has been developed at our institution that is unique in several aspects. The water phantom controller is based on an IBM XT compatible computer. This has been ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596414
更新日期:1989-01-01 00:00:00
abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596427
更新日期:1989-05-01 00:00:00
abstract:PURPOSE:We have developed a robust tool for performing volumetric and temporal analysis of nodules from respiratory gated four-dimensional (4D) CT. The method could prove useful in IMRT of lung cancer. METHODS:We modified the conventional graph-cuts method by adding an adaptive shape prior as well as motion informatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12690
更新日期:2018-01-01 00:00:00
abstract::Myocardial beta adrenergic receptor (beta-AR) concentration can substantially decrease in congestive heart failure and significantly increase in chronic volume overload, such as in severe aortic valve regurgitation. Positron emission tomography (PET) with an appropriate ligand-receptor model can be used for noninvasiv...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2402585
更新日期:2007-01-01 00:00:00
abstract:PURPOSE:Recent guidance by The Joint Commission and CRCPD recommendations require establishing CT reference dose levels (RDLs) for clinical protocols and recording CT dose metrics in the patient's medical record. This presentation addresses which dose values in the CT report should be recorded for the purposes of monit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734773
更新日期:2012-06-01 00:00:00
abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594247
更新日期:1976-09-01 00:00:00
abstract::Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1388219
更新日期:2001-08-01 00:00:00
abstract::Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597344
更新日期:1994-07-01 00:00:00
abstract::When an (exposure) calibrated ionization chamber is used for the determination of absorbed dose from a photon beam, the reading of the instrument must be multiplied by a number of factors, one of which is an attenuation correction for phantom material displaced by the chamber. the magnitude of this correction must dep...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594817
更新日期:1980-11-01 00:00:00
abstract:PURPOSE:Tumor motion during radiotherapy can cause a reduction in target dose coverage and an increase in healthy tissue exposure. Tumor motion is not strictly translational and often exhibits complex six degree-of-freedom (6DoF) translational and rotational motion. Although the dosimetric impact of prostate tumor tran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14502
更新日期:2020-12-01 00:00:00
abstract::The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598412
更新日期:1998-11-01 00:00:00
abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735351
更新日期:2012-06-01 00:00:00
abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598510
更新日期:1999-02-01 00:00:00
abstract::A calculation is described that enables the rapid assessment of dose rate at various points of interest within the eye (lens, optic nerve, etc.) for the treatment of choroidal melanoma by plaque therapy. 125I seeds are used as the radiation source. The location of the plaque and its associated seeds relative to the ey...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596234
更新日期:1988-05-01 00:00:00
abstract::The purpose of this work is to compare the efficacy of mathematical models in predicting the occurrence of radiotherapy-induced left ventricular perfusion defects assessed using single-photon emission computed tomography (SPECT). The basis of this study is data from 73 left-sided breast/ chestwall patients treated wit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1823571
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:High-dose-rate brachytherapy (HDR-BT) is a treatment option for malignant skin diseases compared to external beam radiation therapy, HDR-BT provides improved target coverage, better organ sparing, and has comparable treatment times. This is especially true for large clinical targets with complex topologies. To ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13975
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:To introduce video surface imaging guidance in synchronization with 4D cone-beam CT (CBCT) scans, and in combination with respiration- gated or target-tracked dose delivery to treat mobile tumors, without collaterally damaging nearby critical structures. METHODS:The approach uses the concept that the integral ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734688
更新日期:2012-06-01 00:00:00
abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598839
更新日期:2000-02-01 00:00:00
abstract::Model-based deformable organ registration techniques using the finite element method (FEM) have recently been investigated intensively and applied to image-guided adaptive radiotherapy (IGART). These techniques assume that human organs are linearly elastic material, and their mechanical properties are predetermined. U...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2163838
更新日期:2006-02-01 00:00:00
abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2126207
更新日期:2005-12-01 00:00:00
abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4767754
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:Temporal subtraction is used to detect the interval change in chest radiographs and aid radiologists in patient diagnosis. This method registers two temporally different images by geometrically warping the lung region, or "lung mask," of a previous radiographic image to align with the current image. The gray le...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3259712
更新日期:2009-12-01 00:00:00
abstract:PURPOSE:Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. METHODS:A graph cuts segmentation metho...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3682171
更新日期:2012-03-01 00:00:00
abstract:PURPOSE:The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914398
更新日期:2015-04-01 00:00:00
abstract::Part III (oral exam) is the final part of ABR board exam for Diagnostic Medical Physics. In this exam, each of five oral examiners questions the candidate in each of five question categories. Oral exam has unique challenges to the candidate compared with the written exams. The candidate is expected to have not only ad...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736136
更新日期:2012-06-01 00:00:00
abstract::Stereotactic Body Radiation Therapy (SBRT) is an important form of cancer therapy with increasingly broad application across a spectrum of tumor types in primary and metastatic settings. In this presentation the radiation biology, clinical experience from various trials, and cautionary updates on normal tissue toleran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735812
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To investigate how using different sets of decision criteria impacts the quality of intensity modulated radiation therapy (IMRT) plans obtained by multiobjective optimization. METHODS:A multiobjective optimization evolutionary algorithm (MOEA) was used to produce sets of IMRT plans. The MOEA consisted of two i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3589128
更新日期:2011-06-01 00:00:00
abstract:PURPOSE:The purpose of this paper was to present a method of determining the dose profile of the beam bow-tie filter (BTF) without the need for fixing the x ray tube in a position or using special instruments or dosimeters other than the ordinary types of ion chambers used for CT dosimetry (e.g., Farmer chamber). METH...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13203
更新日期:2018-11-01 00:00:00
abstract:PURPOSE:In intensity-modulated proton therapy (IMPT), protons are used to deliver highly conformal dose distributions, targeting tumors, and sparing organs-at-risk. However, due to uncertainties in both patient setup and relative stopping power (RSP) calculation, margins are added to the treatment volume during treatme...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14347
更新日期:2020-09-01 00:00:00