Displacement corrections used in absorbed dose determination.

Abstract:

:When an (exposure) calibrated ionization chamber is used for the determination of absorbed dose from a photon beam, the reading of the instrument must be multiplied by a number of factors, one of which is an attenuation correction for phantom material displaced by the chamber. the magnitude of this correction must depend on the size and shape of the ionization chamber as well as the energy of the radiation beam. For cobalt-60 radiation, a single number, 0.985, has generally been used. Recent measurements, however, and "first scatter" calculations, of kerma suggest that a more appropriate value for a Farmer-type chamber used in a water phantom would be 0.975. Such a change is small but would be important when dose calculations based on "in phantom" measurements are compared to calculations that are based on in air measurements. Values for the attenuation factor for other beam energies have not been generally available. We have carried out "first scatter' calculations for a rather wide range of energies and spectra. Measurements in 60Co beams and in a high-energy (25 MV) photon beam support the calculations. A set of proposed displacement correction factors is presented.

journal_name

Med Phys

journal_title

Medical physics

authors

Cunningham JR,Sontag MR

doi

10.1118/1.594817

subject

Has Abstract

pub_date

1980-11-01 00:00:00

pages

672-6

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

7

pub_type

杂志文章
  • SU-E-T-203: Development of a QA Software Tool for Automatic Verification of Plan Data Transfer and Delivery.

    abstract:PURPOSE:Consistency verification between the data from treatment planning system (TPS), record and verification system (R&V), and delivered recorder with visual inspection is time consuming and subject to human error. The purpose of this work is to develop a software tool to automatically perform such verifications. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735263

    authors: Chen G,Li X

    更新日期:2012-06-01 00:00:00

  • SU-E-I-41: Characterization of a Linear Fiber-Optic Coupled Dosimeter.

    abstract:PURPOSE:This study investigated the dosimetry performance of a linear fiber-optic coupled dosimeter with a sensitive element varying from 3 to 15 cm in length. The dosimeter is comprised of a tissue equivalent plastic scintillating fiber coupled to a photomultiplier tube (PMT). The sensitive element has a length repres...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734756

    authors: Hoerner M,Hintenlang D

    更新日期:2012-06-01 00:00:00

  • SU-E-T-485: Validation of Acuros XB Dose Calculations in SBRT Lung Planning with Monte Carlo Methods.

    abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735574

    authors: Bush K,Wang L,Mok E

    更新日期:2012-06-01 00:00:00

  • Measurement of primary bremsstrahlung spectrum from an 8-MeV linear accelerator.

    abstract::The bremsstrahlung spectrum from an 8-MeV linear accelerator has been measured using a NaI(T1) spectrometer system. The spectrum shows a low-energy cutoff at 0.4 MeV and the maximum photon energy to be approximately 6% greater than the nominal energy. The maximum emission of energy fluence was 1.6 and 1.8 MeV for meas...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594221

    authors: Levy LB,Waggener RG,Wright AE

    更新日期:1976-05-01 00:00:00

  • Deterministic photon kerma distribution based on the Boltzmann equation for external beam radiation therapy.

    abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2960247

    authors: Yuan J,Jette D,Chen W

    更新日期:2008-09-01 00:00:00

  • SU-E-T-283: Carbon Ion Therapy Innovations in Dosimetry and Dose Delivery.

    abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735351

    authors: Cernica G,Mun S

    更新日期:2012-06-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • ALTIS: A fast and automatic lung and trachea CT-image segmentation method.

    abstract:PURPOSE:The automated segmentation of each lung and trachea in CT scans is commonly taken as a solved problem. Indeed, existing approaches may easily fail in the presence of some abnormalities caused by a disease, trauma, or previous surgery. For robustness, we present ALTIS (implementation is available at http://lids....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13773

    authors: Sousa AM,Martins SB,Falcão AX,Reis F,Bagatin E,Irion K

    更新日期:2019-11-01 00:00:00

  • In vivo surface dosimetry with a scintillating fiber dosimeter in preclinical image-guided radiotherapy.

    abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13903

    authors: Le Deroff C,Pérès EA,Ledoux X,Toutain J,Frelin-Labalme AM

    更新日期:2020-01-01 00:00:00

  • The determination of electron density by the dual-energy Compton scatter method.

    abstract::The intensity of Compton scattered photons is directly proportional to the electron density of a substance; therefore it is possible to detect changes in electron density by this noninvasive method. The source-detector geometry has been varied to study the effects of geometry on the calculated electron density values,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595730

    authors: Huddleston AL,Sackler JP

    更新日期:1985-01-01 00:00:00

  • SU-E-T-590: Procedure for Verification and Inter-Comparison of IMRT Beam Models.

    abstract:PURPOSE:The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quali...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735679

    authors: Veltchev I,Fourkal E,Price R,Ma C

    更新日期:2012-06-01 00:00:00

  • A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates.

    abstract::The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598412

    authors: Kengyelics SM,Davies AG,Cowen AR

    更新日期:1998-11-01 00:00:00

  • Toward the combined optimization of dynamic axes (CODA) for stereotactic radiotherapy and radiosurgery using fixed couch trajectories.

    abstract:PURPOSE:To develop a novel system for patient-specific combined optimization of couch, collimator, and gantry angles for use in volumetric modulated arc therapy (VMAT) treatment planning. The system was designed to produce highly compact dose distributions by extensively sampling the 4π space. Automated fixed couch tra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13887

    authors: MacDonald RL,Syme A,Little B,Ward L,Thomas CG

    更新日期:2020-02-01 00:00:00

  • Objected constrained registration and manifold learning: a new patient setup approach in image guided radiation therapy of thoracic cancer.

    abstract:PURPOSE:The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. METHODS:For 11 lung cancer patients a long training fluoroscopy was acquired before the first trea...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.4794489

    authors: Chen T,Jabbour SK,Qin S,Haffty BG,Yue N

    更新日期:2013-04-01 00:00:00

  • Influence of phantom diameter, kVp and scan mode upon computed tomography dose index.

    abstract::The computed tomography (CT) radiation dose to pediatric patients has received considerable attention recently. Moreover, it is important to be able to determine CT radiation doses for various patient sizes ranging from infants to large adults. The current AAPM protocol only measures CT radiation dose using a 16 cm ac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1543149

    authors: Nickoloff EL,Dutta AK,Lu ZF

    更新日期:2003-03-01 00:00:00

  • A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals.

    abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4926551

    authors: Woerner A,Roeske JC,Harkenrider MM,Fan J,Aydogan B,Koshy M,Laureckas R,Vali F,Campana M,Surucu M

    更新日期:2015-08-01 00:00:00

  • Eye tracking and gating system for proton therapy of orbital tumors.

    abstract:PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729708

    authors: Shin D,Yoo SH,Moon SH,Yoon M,Lee SB,Park SY

    更新日期:2012-07-01 00:00:00

  • Characterization of fragmented heavy-ion beams using a three-stage telescope detector: measurements of 670-MeV/amu 20Ne beams.

    abstract::Measurements of a 670-MeV/amu 20Ne beam at the Lawrence Berkeley Laboratory Bevalac heavy-ion accelerator with various thicknesses of water absorber were obtained with the BERKLET. The BERKLET, a simple three-stage solid-state telescope detector, has been described previously. This instrument measures the linear energ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596536

    authors: Llacer J,Schmidt JB,Tobias CA

    更新日期:1990-03-01 00:00:00

  • Kilovoltage stereotactic radiosurgery for age-related macular degeneration: assessment of optic nerve dose and patient effective dose.

    abstract::Age-related macular degeneration (AMD) is a leading cause for vision loss for people over the age of 65 in the United States and a major health problem worldwide. Research for new treatments of the wet form of the disease using kilovoltage stereotactic radiosurgery is currently underway at Oraya Therapeutics, Inc. In ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3168554

    authors: Hanlon J,Lee C,Chell E,Gertner M,Hansen S,Howell RW,Bolch WE

    更新日期:2009-08-01 00:00:00

  • Design and evaluation of an MRI-compatible linear motion stage.

    abstract:PURPOSE:To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS:In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937780

    authors: Tavallaei MA,Johnson PM,Liu J,Drangova M

    更新日期:2016-01-01 00:00:00

  • WE-F-211-01: The Evolving Landscape of Scientific Publishing.

    abstract::The dissemination of scientific advances has changed little since the first peer-reviewed journal was published in 1665 - that is, until this past decade. The print journal, delivered by mail and stored on office shelves and in library reading rooms around the world, has been transformed by immediate, on-demand access...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736173

    authors: Armato S,Hendee W,Marshall C,Curran B

    更新日期:2012-06-01 00:00:00

  • A multipinhole small animal SPECT system with submillimeter spatial resolution.

    abstract::Single photon emission computed tomography (SPECT) is an important technology for molecular imaging studies of small animals. In this arena, there is an increasing demand for high performance imaging systems that offer improved spatial resolution and detection efficiency. We have designed a multipinhole small animal i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2190332

    authors: Funk T,Després P,Barber WC,Shah KS,Hasegawa BH

    更新日期:2006-05-01 00:00:00

  • Direct-response ultraviolet thermoluminescent dosimeter.

    abstract::An integrating solid-state dosimeter has been developed to detect ultraviolet radiation using the process of "direct" ultraviolet stimulation. This process yields a thermoluminescent signal after an exposure to ultraviolet radiation, without prior exposure to ionizing radiation. Magnesium oxide crystals were found to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594259

    authors: Dhar A,DeWerd LA,Stoebe TG

    更新日期:1976-11-01 00:00:00

  • Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma.

    abstract:PURPOSE:Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as inter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4948999

    authors: Guo F,Svenningsen S,Eddy RL,Capaldi DPI,Sheikh K,Fenster A,Parraga G

    更新日期:2016-06-01 00:00:00

  • SU-E-T-210: Surviving a Visit by the Radiological Physics Center.

    abstract:PURPOSE:To demonstrate an objective approach to determining if a negative report from the Radiological Physics Center (RPC) of greater than 10% error is valid or has clinical significance. METHODS:The discrepancy involved the clinical activity (mgRaEq) of Cs-137 sources, some manufactured by 3M and some by Amersham. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735271

    authors: Grant W 3rd,Mcgary J,Rosen I,Nitsch P,Davidson S

    更新日期:2012-06-01 00:00:00

  • Attenuation, scattering, and absorption of ultrasound in the skull bone.

    abstract:PURPOSE:Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its comple...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3668316

    authors: Pinton G,Aubry JF,Bossy E,Muller M,Pernot M,Tanter M

    更新日期:2012-01-01 00:00:00

  • Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters.

    abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3429089

    authors: Raffi JA,Davis SD,Hammer CG,Micka JA,Kunugi KA,Musgrove JE,Winston JW Jr,Ricci-Ott TJ,DeWerd LA

    更新日期:2010-06-01 00:00:00

  • Improving the calibration of radiochromic films by the use of uncertainties in optical density and dose.

    abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811238

    authors: Garcia LI,Azorin JF

    更新日期:2013-07-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • Simultaneous super-resolution and contrast synthesis of routine clinical magnetic resonance images of the knee for improving automatic segmentation of joint cartilage: data from the Osteoarthritis Initiative.

    abstract:PURPOSE:High resolution three-dimensional (3D) magnetic resonance (MR) images are well suited for automated cartilage segmentation in the human knee joint. However, volumetric scans such as 3D Double-Echo Steady-State (DESS) images are not routinely acquired in clinical practice which limits opportunities for reliable ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14421

    authors: Neubert A,Bourgeat P,Wood J,Engstrom C,Chandra SS,Crozier S,Fripp J

    更新日期:2020-10-01 00:00:00