Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures.

Abstract:

PURPOSE:In this report, the authors introduce the general concept of the completeness map, as a means to evaluate the completeness of data acquired by a given CT system design (architecture and scan mode). They illustrate the utility of completeness map by applying the completeness map concept to a number of candidate CT system designs, as part of a study to advance the state-of-the-art in cardiac CT. METHODS:In order to optimally reconstruct a point within a volume of interest (VOI), the Radon transform on all possible planes through that point should be measured. The authors quantified the extent to which this ideal condition is satisfied for the entire image volume. They first determined a Radon completeness number for each point in the VOI, as the percentage of possible planes that is actually measured. A completeness map is then defined as a 3D matrix of the completeness numbers for the entire VOI. The authors proposed algorithms to analyze the projection datasets in Radon space and compute the completeness number for a fixed point and apply these algorithms to various architectures and scan modes that they are evaluating. In this report, the authors consider four selected candidate architectures, operating with different scan modes, for a total of five system design alternatives. Each of these alternatives is evaluated using completeness map. RESULTS:If the detector size and cone angle are large enough to cover the entire cardiac VOI, a single-source circular scan can have ≥99% completeness over the entire VOI. However, only the central z-slice can be exactly reconstructed, which corresponds to 100% completeness. For a typical single-source architecture, if the detector is limited to an axial dimension of 40 mm, a helical scan needs about five rotations to form an exact reconstruction region covering the cardiac VOI, while a triple-source helical scan only requires two rotations, leading to a 2.5x improvement in temporal resolution. If the source and detector of an inverse-geometry (IGCT) system have the same axial extent, and the spacing of source points in the axial and transaxial directions is sufficiently small, the IGCT can also form an exact reconstruction region for the cardiac VOI. If the VOI can be covered by the x-ray beam in any view, a composite-circling scan can generate an exact reconstruction region covering the VOI. CONCLUSIONS:The completeness map evaluation provides useful information for selecting the next-generation cardiac CT system design. The proposed completeness map method provides a practical tool for analyzing complex scanning trajectories, where the theoretical image quality for some complex system designs is impossible to predict, without yet-undeveloped reconstruction algorithms.

journal_name

Med Phys

journal_title

Medical physics

authors

Liu B,Bennett J,Wang G,De Man B,Zeng K,Yin Z,Fitzgerald P,Yu H

doi

10.1118/1.3700172

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

2405-16

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Effect of patient support pads on image quality and dose in fluoroscopy.

    abstract::An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597906

    authors: Geiser WR,Huda W,Gkanatsios NA

    更新日期:1997-03-01 00:00:00

  • Iodine quantification in limited angle tomography.

    abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14400

    authors: Michielsen K,Rodríguez-Ruiz A,Reiser I,Nagy JG,Sechopoulos I

    更新日期:2020-10-01 00:00:00

  • X-ray spectral reconstruction from attenuation data using neural networks.

    abstract::An artificial neural network using input data derived from attenuation measurements was trained to generate spectral profiles (relative number of photons versus energy). Once the relative spectral distribution is reconstructed, absolute spectra (number of photons per unit exposure spectral distribution is reconstructe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596495

    authors: Boone JM

    更新日期:1990-07-01 00:00:00

  • An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams.

    abstract::The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irrad...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598593

    authors: Mobit PN,Sandison GA

    更新日期:1999-05-01 00:00:00

  • Evaluation of video gray-scale display.

    abstract::Setting up and maintaining video display monitors properly will help to reduce display variation and improve overall presentation of the radiological image. Display monitor gray-scale characteristics were examined using the SMPTE test pattern. This test pattern may be used as a standard for adjusting brightness and co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596846

    authors: Nawfel RD,Chan KH,Wagenaar DJ,Judy PF

    更新日期:1992-05-01 00:00:00

  • 3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification.

    abstract::Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2936229

    authors: Stancanello J,Muacevic A,Sebastiano F,Modugno N,Cerveri P,Ferrigno G,Uggeri F,Romanelli P

    更新日期:2008-07-01 00:00:00

  • Future of medical physics: Real-time MRI-guided proton therapy.

    abstract::With the recent clinical implementation of real-time MRI-guided x-ray beam therapy (MRXT), attention is turning to the concept of combining real-time MRI guidance with proton beam therapy; MRI-guided proton beam therapy (MRPT). MRI guidance for proton beam therapy is expected to offer a compelling improvement to the c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12371

    authors: Oborn BM,Dowdell S,Metcalfe PE,Crozier S,Mohan R,Keall PJ

    更新日期:2017-08-01 00:00:00

  • Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS).

    abstract::Digital tomosynthesis (DTS) is a fast, low-dose three-dimensional (3D) imaging approach which yields slice images with excellent in-plane resolution, though low plane-to-plane resolution. A stack of DTS slices can be reconstructed from a single limited-angle scan, with typical scan angles ranging from 10 degrees to 40...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2756941

    authors: Godfrey DJ,Ren L,Yan H,Wu Q,Yoo S,Oldham M,Yin FF

    更新日期:2007-08-01 00:00:00

  • Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations.

    abstract::Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S val...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3103401

    authors: Pacilio M,Lanconelli N,Lo MS,Betti M,Montani L,Torres AL,Coca PM

    更新日期:2009-05-01 00:00:00

  • Unexpectedly large dose rate dependent output from a linear accelerator.

    abstract::During our routine calibration of a Varian Clinac-20 linear accelerator, the absorbed dose for a fixed monitor unit (mu) was found to decrease with increasing dose rate. Between dose rates of 100 and 500 mu/min, there was up to 20% difference in absorbed dose for a 20-MeV electron beam. The cause of this problem was a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596192

    authors: Cheng PC,Kubo H

    更新日期:1988-09-01 00:00:00

  • SU-E-T-236: Brachytherapy for Breast Cancer Patients with Implanted Pacemeker, Using Multi Lumen Partial Breast Applicator.

    abstract:PURPOSE:Discuss optimised Accelerated Partial Breast Irradiation (APBI) using a Strut-Adjused Volume Implant (SAVI) applicator for patients with implanted pacemeker, without overdosing or relocating the pacemaker. METHODS:A right breast cancer patient with an in situ pacemaker (Medtronic model ADDR01) on the right sid...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735299

    authors: Jacob D,Strasser J

    更新日期:2012-06-01 00:00:00

  • Characterization of tissue-specific pre-log Bayesian CT reconstruction by texture-dose relationship.

    abstract:PURPOSE:Tissue textures have been recognized as biomarkers for various clinical tasks. In computed tomography (CT) image reconstruction, it is important but challenging to preserve the texture when lowering x-ray exposure from full- toward low-/ultra-low dose level. Therefore, this paper aims to explore the texture-dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14449

    authors: Gao Y,Liang Z,Xing Y,Zhang H,Pomeroy M,Lu S,Ma J,Lu H,Moore W

    更新日期:2020-10-01 00:00:00

  • Shimming with permanent magnets for the x-ray detector in a hybrid x-ray/ MR system.

    abstract::In this x-ray/MR hybrid system an x-ray flat panel detector is placed under the patient cradle, close to the MR volume of interest (VOI), where the magnetic field strength is approximately 0.5 T. Immersed in this strong field, several electronic components inside the detector become magnetized and create an additional...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2963994

    authors: Wen Z,Fahrig R,Williams ST,Pelc NJ

    更新日期:2008-09-01 00:00:00

  • Classification of breast lesions using segmented quantitative ultrasound maps of homodyned K distribution parameters.

    abstract:PURPOSE:Statistical modeling of an ultrasound backscattered echo envelope is used for tissue characterization. However, in the presence of complex structures within the analyzed area, estimation of parameters is disturbed and unreliable, e.g., in the case of breast tumor classification. In order to improve the differen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962928

    authors: Byra M,Nowicki A,Wróblewska-Piotrzkowska H,Dobruch-Sobczak K

    更新日期:2016-10-01 00:00:00

  • Investigation of basic imaging properties in digital radiography. 9. Effect of displayed grey levels on signal detection.

    abstract::Results of an 18-alternative forced-choice experiment have shown that observers were capable of detecting a signal with a contrast of 1 in terms of 10-bit data which were displayed on a CRT monitor with an 8-bit video generator and a window width setting of 1024. We investigated the conditions under which 10-bit signa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595919

    authors: Giger ML,Ohara K,Doi K

    更新日期:1986-05-01 00:00:00

  • Depth dose characteristics of 24-MV x-ray beams at extended SSD.

    abstract::Depth dose characteristics of 24-MV beams from a medical linear accelerator at various SSDs have been measured. The dose buildup, percent depth dose (PDD), and output were measured using ionization chambers and a diode detector under full scatter. Surface dose ranged from 8% to 51% depending upon the collimator settin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596673

    authors: Jani SK,Pennington EC

    更新日期:1991-03-01 00:00:00

  • Accurate technique for complete geometric calibration of cone-beam computed tomography systems.

    abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1869652

    authors: Cho Y,Moseley DJ,Siewerdsen JH,Jaffray DA

    更新日期:2005-04-01 00:00:00

  • Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

    abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1414008

    authors: Dohm OS,Christ G,Nüsslin F,Schüle E,Bruggmoser G

    更新日期:2001-11-01 00:00:00

  • Determination of x-ray tube focal spot position.

    abstract::In x-ray spectral measurement using a semiconductor detector system, accurate positioning of the detector in front of the anode is very important. This needs accurate determination of the focal spot position on the target in an x-ray tube. We present a simple technique to determine the focal spot position accurately. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597122

    authors: Kubota H,Ozaki Y,Matsumoto M,Kanamori H

    更新日期:1993-07-01 00:00:00

  • Sci-Fri PM: Planning-04: Dose escalation study using anatomy-based aperture IMRT and SPECT perfusion images for lung cancer.

    abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965976

    authors: St-Hilaire J,Lavoie C,Beaulieu F,Dagnault A,Morin F,Gingras L,Tremblay D,Beaulieu L

    更新日期:2008-07-01 00:00:00

  • A comparative study of rectal dose histograms in prostate brachytherapy: some analytic and numerical results.

    abstract::A cumulative dose histogram is the graph of an integral function integrated over a domain VCR3 and is dubbed the dose-volume histogram (DVH), the dose-surface histogram (DSH) or the dose-wall histogram (DWH), depending on the dimension and structure of the region V. This paper presents a comparative study of the three...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1852811

    authors: Song JS,Albert M,D'Amico AV,Cormack RA

    更新日期:2005-02-01 00:00:00

  • Experimental characterization of the miniannular phased array as a hyperthermia applicator.

    abstract::A series of experiments has been carried out in order to characterize a miniannular phased array applicator prior to possible clinical implementation. The energy deposition patterns over the frequency range of 100 to 200 MHz were determined in several human limb models of different complexities by measuring the electr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596037

    authors: Guerquin-Kern JL,Hagmann MJ,Levin RL

    更新日期:1987-07-01 00:00:00

  • On using an adaptive neural network to predict lung tumor motion during respiration for radiotherapy applications.

    abstract::In this study we address the problem of predicting the position of a moving lung tumor during respiration on the basis of external breathing signals--a technique used for beam gating, tracking, and other dynamic motion management techniques in radiation therapy. We demonstrate the use of neural network filters to corr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2134958

    authors: Isaksson M,Jalden J,Murphy MJ

    更新日期:2005-12-01 00:00:00

  • Combined mixed approach algorithm for in-line phase-contrast x-ray imaging.

    abstract:PURPOSE:In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3447727

    authors: De Caro L,Scattarella F,Giannini C,Tangaro S,Rigon L,Longo R,Bellotti R

    更新日期:2010-07-01 00:00:00

  • Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

    abstract:PURPOSE:Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3560428

    authors: Gang GJ,Lee J,Stayman JW,Tward DJ,Zbijewski W,Prince JL,Siewerdsen JH

    更新日期:2011-04-01 00:00:00

  • Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET.

    abstract::The GEANT4 application for tomographic emission (GATE) is one of the most detailed Monte Carlo simulation tools for SPECT and PET. It allows for realistic phantoms, complex decay schemes, and a large variety of detector geometries. However, only a fraction of the information in each particle history is available for p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3078045

    authors: De Beenhouwer J,Staelens S,Vandenberghe S,Verhaeghe J,Van Holen R,Rault E,Lemahieu I

    更新日期:2009-04-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • Comparison of three strategies in management of independent movement of the prostate and pelvic lymph nodes.

    abstract:PURPOSE:Concurrent irradiation of the prostate and pelvic lymph nodes is technically challenging due to treating one moving target and one immobile target. The purposes of this article are to propose a new management strategy and to compare this strategy to the conventional isocenter shift method and the previously pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3480505

    authors: Xia P,Qi P,Hwang A,Kinsey E,Pouliot J,Roach M 3rd

    更新日期:2010-09-01 00:00:00

  • Laser heating of thermoluminescent plates: application to intraoperative radiotherapy.

    abstract::A new system of radiation dose mapping based on laser heating of thermoluminescent dosimetric plates (TLDP) has been developed. Application of this technique to intraoperative radiotherapy (IORT) has been investigated. Preliminary results show that TLDP are a possible alternative to radiological films and ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597725

    authors: Beteille D,Setzkom R,Prévost H,Dusseau L,Fesquet J,Gasiot J,Muraro S,Delard R,Dubois JB,Ailleres N,Missous O

    更新日期:1996-08-01 00:00:00

  • Analytical probabilistic modeling of dose-volume histograms.

    abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14414

    authors: Wahl N,Hennig P,Wieser HP,Bangert M

    更新日期:2020-10-01 00:00:00