Library based x-ray scatter correction for dedicated cone beam breast CT.

Abstract:

PURPOSE:The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. METHODS:The authors precompute a scatter library on simplified breast models with different sizes using the geant4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. RESULTS:Since the time-consuming MC simulation for library generation is precomputed, the authors' method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors' method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. CONCLUSIONS:The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors' approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.

journal_name

Med Phys

journal_title

Medical physics

authors

Shi L,Vedantham S,Karellas A,Zhu L

doi

10.1118/1.4955121

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

4529

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • An investigation of a new amorphous silicon electronic portal imaging device for transit dosimetry.

    abstract::The relationship between the pixel value and exit dose was investigated for a new commercially available amorphous silicon electronic portal imaging device. The pixel to dose mapping function was established to be linear for detector distances between 116.5 cm to 150 cm from the source, radiation field sizes from 5 x ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1508108

    authors: Grein EE,Lee R,Luchka K

    更新日期:2002-10-01 00:00:00

  • Fast reconstruction with uniform noise properties in halfscan computed tomography.

    abstract::The hybrid algorithms developed recently for the reconstruction of fan-beam images possess computational and noise properties superior to those of the fan-beam filtered backprojection (FFBP) algorithm. However, the hybrid algorithms cannot be applied directly to a halfscan fan-beam sinogram because they require knowle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1288239

    authors: Pan X

    更新日期:2000-09-01 00:00:00

  • A Monte Carlo comparison of the response of the PTW-diamond and the TL-diamond detectors in megavoltage photon beams.

    abstract::A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598771

    authors: Mobit PN,Sandison GA

    更新日期:1999-11-01 00:00:00

  • SU-E-J-43: Autotuning Imaging Parameters in X-Ray Fluoroscopic Tracking for Dose Savings.

    abstract:PURPOSE:In fluoroscopy-guided clinical procedures that involve tracking objects over long treatment times, there is a need for reducing the amount of imaging dose delivered to the patient and the operating staff. In this study, we introduce a feedback metric to minimize tube current while maintaining a targeting precis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734878

    authors: Siddique S,Fiume E,Jaffray D

    更新日期:2012-06-01 00:00:00

  • Displacement and strain estimation for evaluation of arterial wall stiffness using a familial hypercholesterolemia swine model of atherosclerosis.

    abstract:PURPOSE:To track variations in the deformation of the arterial wall noninvasively by estimating the accumulated displacement and strain over a cardiac cycle may provide useful indicators of vascular health. METHODS:In this paper, we propose an approach to track a region of interest (ROI) locally and estimate arterial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722746

    authors: Ge W,Krueger CG,Weichmann A,Shanmuganayagam D,Varghese T

    更新日期:2012-07-01 00:00:00

  • Computation of energy imparted in diagnostic radiology.

    abstract::Energy imparted is a measure of the total ionizing energy deposited in the patient during a radiologic examination and may be used to quantify the patient dose in diagnostic radiology. Values of the energy imparted per unit exposure-area product, omega (z), absorbed by a semi-infinite water phantom with a thickness z,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597939

    authors: Gkanatsios NA,Huda W

    更新日期:1997-04-01 00:00:00

  • Ethics and professionalism in medical physics: a survey of AAPM members.

    abstract:PURPOSE:To assess current education, practices, attitudes, and perceptions pertaining to ethics and professionalism in medical physics. METHODS:A link to a web-based survey was distributed to the American Association of Physicists in Medicine (AAPM) e-mail membership list, with a follow-up e-mail sent two weeks later....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4797463

    authors: Ozturk N,Armato SG 3rd,Giger ML,Serago CF,Ross LF

    更新日期:2013-04-01 00:00:00

  • Three dimensional intensity modulated brachytherapy (IMBT): dosimetry algorithm and inverse treatment planning.

    abstract:PURPOSE:The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3456598

    authors: Shi C,Guo B,Cheng CY,Esquivel C,Eng T,Papanikolaou N

    更新日期:2010-07-01 00:00:00

  • Technical Note: Correction for intra-chamber dose gradients in reference dosimetry of flattening-filter-free MV photon beams.

    abstract:PURPOSE:To estimate and correct for the volume averaging effect which results from the intra-chamber dose gradients when a Farmer ionization chamber (IC) is used for reference dosimetry in flattening-filter-free (FFF) MV photon beams. METHODS:An intra-chamber dose gradients correction factor (kicdg) to the charge read...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958960

    authors: Ruggieri R,Naccarato S,Stavrev P,Stavreva N,Pasetto S,Salamone I,Alongi F

    更新日期:2016-08-01 00:00:00

  • Application of the convolution method for calculation of output factors for therapy photon beams.

    abstract::The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596859

    authors: Ahnesjö A,Knöös T,Montelius A

    更新日期:1992-03-01 00:00:00

  • Balancing dose and image registration accuracy for cone beam tomosynthesis (CBTS) for breast patient setup.

    abstract:PURPOSE:To balance dose reduction and image registration accuracy in breast setup imaging. In particular, the authors demonstrate the relationship between scan angle and dose delivery for cone beam tomosynthesis (CBTS) when employed for setup verification of breast cancer patients with surgical clips. METHODS:The dose...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3464716

    authors: Winey BA,Zygmanski P,Cormack RA,Lyatskaya Y

    更新日期:2010-08-01 00:00:00

  • Scatter transmission through an ideal grid.

    abstract::An analytic expression is derived for the transmission of isotropic scattered radiation incident upon an ideal parallel grid. It is found that the expression for the transmission usually found in the literature overestimates the transmission by approximately a factor of two. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594877

    authors: Siddon RL

    更新日期:1981-11-01 00:00:00

  • Temporal stability assessment in shear wave elasticity images validated by deep learning neural network for chronic liver disease fibrosis stage assessment.

    abstract:PURPOSE:To automatically detect and isolate areas of low and high stiffness temporal stability in shear wave elastography (SWE) image sequences and define their impact in chronic liver disease (CLD) diagnosis improvement by means of clinical examination study and deep learning algorithm employing convolutional neural n...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13521

    authors: Gatos I,Tsantis S,Spiliopoulos S,Karnabatidis D,Theotokas I,Zoumpoulis P,Loupas T,Hazle JD,Kagadis GC

    更新日期:2019-05-01 00:00:00

  • Semiautomated registration of pre- and intraoperative CT for image-guided percutaneous liver tumor ablation interventions.

    abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12332

    authors: Gunay G,Luu MH,Moelker A,van Walsum T,Klein S

    更新日期:2017-07-01 00:00:00

  • Physical models, cross sections, and numerical approximations used in MCNP and GEANT4 Monte Carlo codes for photon and electron absorbed fraction calculation.

    abstract:PURPOSE:Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3242304

    authors: Yoriyaz H,Moralles M,Siqueira Pde T,Guimarães Cda C,Cintra FB,dos Santos A

    更新日期:2009-11-01 00:00:00

  • Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

    abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2739805

    authors: Liu X,Shaw CC

    更新日期:2007-07-01 00:00:00

  • A Laplace transform pair model for spectral reconstruction.

    abstract::A four-parameter Laplace transform pair model, which accurately reconstructs an experimental bremsstrahlung spectrum from attenuation data, is presented. Computed spectral values with both aluminum and copper attenuators generally agree with experimental 70-kVp data to better than 2%. Reconstructed spectra at other kV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595193

    authors: Archer BR,Wagner LK

    更新日期:1982-11-01 00:00:00

  • Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy.

    abstract:PURPOSE:Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4754799

    authors: Fogliata A,Garcia R,Knoos T,Nicolini G,Clivio A,Vanetti E,Khamphan C,Cozzi L

    更新日期:2012-10-01 00:00:00

  • Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields.

    abstract::Because of complex dose distributions and dose gradients that are created in three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), photon- and electron-energy spectra might change significantly with spatial locations and doses. This study examined variations in photon- and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2710550

    authors: Jang SY,Liu HH,Mohan R,Siebers JV

    更新日期:2007-04-01 00:00:00

  • Noise correlations in images acquired simultaneously with a dual-energy sandwich detector.

    abstract::An energy discriminating detector for dual-energy radiography can be configured as a two-layer sandwich, where the mean energy of photons detected by the two layers differs. To characterize the quantum noise of such a detector, the noise covariance between the two layers must be known in addition to the noise variance...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596311

    authors: Sones RA,Barnes GT

    更新日期:1989-11-01 00:00:00

  • Sci-Thur AM: Planning - 10: Improved dosimetric accuracy for patient specific quality assurance using a dual-detector measurement method for cyberknife output factors.

    abstract::The measurement of output factors for small fields is challenging and can lead to large dose errors in patient treatments if corrections for detector size and scatter from high-Z material are not applied. Due to its high spatial resolution and near tissue equivalence, GAFCHROMIC® film potentially provides a correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740095

    authors: Vandervoort E,La Russa D,Ploquin N,Kadir IAE,Szanto J

    更新日期:2012-07-01 00:00:00

  • MO-F-213AB-01: Improving Dose Uniformity in Patch-Field Proton Therapy Using Beam Current Modulation.

    abstract:PURPOSE:To improve the dose homogeneity in patch-field proton therapy using beam current modulation. METHODS:MCNPX simulations were performed for various configurations of the Mevion S250 beamline. Spread-out Bragg peak (SOBP) dose distributions were calculated, and lateral and distal dose profiles were extracted for ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735806

    authors: Hill P,Klein E,Bloch C

    更新日期:2012-06-01 00:00:00

  • Sinusoidal modulation analysis for optical system MTF measurements.

    abstract::The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597840

    authors: Boone JM,Yu T,Seibert JA

    更新日期:1996-12-01 00:00:00

  • Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy.

    abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595546

    authors: Higashida Y,Doi K,Lehr JL,MacMahon H

    更新日期:1984-09-01 00:00:00

  • On the conditioning of basis materials and its impact on multi-material decomposition based spectral imaging in photon-counting CT.

    abstract:PURPOSE:Material-specific imaging and virtual monochromatic imaging/analysis are the two forms of spectral imaging in CT implemented via either energy-integration or photon-counting data acquisition. Aimed at further understanding the fundamentals and providing guidelines on its design and implementation, we quantitati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14708

    authors: Tang X,Ren Y

    更新日期:2021-01-07 00:00:00

  • Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

    abstract::The purpose of this study is to develop a 4D inverse planning strategy capable of controlling the appearance of the implanted fiducial(s) in segmented IMRT fields for cine MV or combined MV/kV image-guided IMRT. This work is focused on enhancing the visibility of the implanted fiducial(s) in 4D IMRT inverse planning, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3121425

    authors: Ma Y,Lee L,Keshet O,Keall P,Xing L

    更新日期:2009-06-01 00:00:00

  • Penetration quality measurement for standardization of radiographic image quality.

    abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594156

    authors: Lin PJ

    更新日期:1975-01-01 00:00:00

  • Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6-20 MeV).

    abstract::Monte Carlo (MC) techniques can be used to build a simulation model of an electron accelerator to calculate output factors for electron fields. This can be useful during commissioning of electron beams from a linac and in clinical practice where irregular fields are also encountered. The Monte Carlo code BEAM/EGS4 was...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1373402

    authors: Verhaegen F,Mubata C,Pettingell J,Bidmead AM,Rosenberg I,Mockridge D,Nahum AE

    更新日期:2001-06-01 00:00:00

  • Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

    abstract::To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan F...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1381549

    authors: Liu Y,Liu H,Wang Y,Wang G

    更新日期:2001-07-01 00:00:00

  • Multiattribute probabilistic prostate elastic registration (MAPPER): application to fusion of ultrasound and magnetic resonance imaging.

    abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905104

    authors: Sparks R,Bloch BN,Feleppa E,Barratt D,Moses D,Ponsky L,Madabhushi A

    更新日期:2015-03-01 00:00:00