SU-E-T-398: Verification of Gamma Knife EXtend System Based Fractionated Treatment Planning Using EBT2 Film.

Abstract:

PURPOSE:To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS:A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for eXtend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion6) of the phantom was obtained with following parameters: Tube Voltage - 110 kV, Tube Current - 280 mA, pixel size - 0.5 mm × 0.5 mm and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sector blocking in each shot was made. Dose prescription of 4.0 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 Gy to 12 Gy doses for calibration purpose. EPSON (Expression 10000XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with in-house made Matlab codes. RESULTS:Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for different tolerance criteria of 2%/2mm, 1%/1mm, and 0.5%/0.5mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane was in close agreement. CONCLUSIONS:Through this study we propose a treatment verification QA method for eXtend frame based fractionated Gamma Knife radiosurgery using EBT2 film. Acknowledgement: Authors acknowledge the help of Andre Micke, ISP for sharing his expertise on EBT2 film.

journal_name

Med Phys

journal_title

Medical physics

authors

Gopishankar N,Bisht RK

doi

10.1118/1.4735487

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3796

issue

6Part16

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Thermodynamic considerations of acrylic cement implant at the site of giant cell tumors of the bone.

    abstract::A discussion of the thermodynamic aspects of a relatively new treatment method for giant cell tumors of the bone is presented in this paper. The advantages of implanting methylmethacrylate acrylic bone cement into a curetted tumor site are briefly discussed and placed in perspective relative to more prevalent surgical...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595902

    authors: Krishnan EC,Nelson C,Neff JR

    更新日期:1986-03-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • Effects of tumor motion in GRID therapy.

    abstract::Clinical and biological evidence suggest that the success of GRID therapy in debulking large tumors depends on the high peak-to-valley contrast in the dose distribution. In this study, we show that the peaks and valleys can be significantly blurred out by respiration-induced tumor motion, possibly affecting the clinic...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2977538

    authors: Naqvi SA,Mohiuddin MM,Ha JK,Regine WF

    更新日期:2008-10-01 00:00:00

  • MLC quality assurance techniques for IMRT applications.

    abstract::Intensity modulated radiotherapy (IMRT) requires extensive knowledge of multileaf collimator (MLC) leaf positioning accuracy, precision, and long-term reproducibility. We have developed a technique to efficiently measure the absolute position of each MLC leaf, over the range of leaf positions utilized in IMRT, based o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1564091

    authors: Bayouth JE,Wendt D,Morrill SM

    更新日期:2003-05-01 00:00:00

  • WE-E-BRA-03: MR Functional Imaging to Guide Radiotherapy: Opportunities and Challenges in the Clinic.

    abstract::Human tumors are characterized by an abnormal vascular network that develops because of unregulated angiogenesis. This contributes to abnormalities of the tumor microenvironment like hypoxia, acidosis and high interstitial fluid pressure that influence treatment response and patient survival. There is an important cli...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736156

    authors: Milosevic M

    更新日期:2012-06-01 00:00:00

  • A controlled phantom study of a noise equalization algorithm for detecting microcalcifications in digital mammograms.

    abstract::We report on some extensions and further developments of a well-known microcalcification detection algorithm based on adaptive noise equalization. Tissue equivalent phantom images with and without labeled microcalcifications were subjected to this algorithm, and analyses of results revealed some shortcomings in the ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1359245

    authors: Gürün OO,Fatouros PP,Kuhn GM,de Paredes ES

    更新日期:2001-04-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Influence of cold walls on PET image quantification and volume segmentation: a phantom study.

    abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813302

    authors: Berthon B,Marshall C,Edwards A,Evans M,Spezi E

    更新日期:2013-08-01 00:00:00

  • Detecting electron beam energy shifts with a commercially available energy monitor.

    abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599033

    authors: Evans MD,Moftah BA,Olivares M,Podgorsak EB

    更新日期:2000-07-01 00:00:00

  • Recognition of healthy and cancerous breast cells: Sensing the differences by dielectric spectroscopy.

    abstract:PURPOSE:The response of human cells to applied electrical signals depends on the cellular health status, because it is influenced by the composition and structure of the main cellular components. Therefore, electrical impedance-based techniques can be considered as sensitive tools to investigate healthy or disease stat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14425

    authors: Ambrico M,Lasalvia M,Ligonzo T,Ambrico PF,Perna G,Capozzi V

    更新日期:2020-10-01 00:00:00

  • SU-E-T-622: A Rapid Hybrid VMAT-IMRT Planning Method Using an Abbreviated Beam Angle Optimization Search.

    abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735712

    authors: Schulze D,Ionascu D,Tyagi N

    更新日期:2012-06-01 00:00:00

  • The DosiMap, a new 2D scintillating dosimeter for IMRT quality assurance: characterization of two Cerenkov discrimination methods.

    abstract::New radiation therapy techniques such as IMRT present significant efficiency due to their highly conformal dose distributions. A consequence of the complexity of their dose distributions (high gradients, small irradiation fields, low dose distribution, ...) is the requirement for better precision quality assurance tha...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2897966

    authors: Frelin AM,Fontbonne JM,Ban G,Colin J,Labalme M,Batalla A,Vela A,Boher P,Braud M,Leroux T

    更新日期:2008-05-01 00:00:00

  • Factors influencing the performance of patient specific quality assurance for pencil beam scanning IMPT fields.

    abstract:PURPOSE:A detailed analysis of 2728 intensity modulated proton therapy (IMPT) fields that were clinically delivered to patients between 2007 and 2013 at Paul Scherrer Institute (PSI) was performed. The aim of this study was to analyze the results of patient specific dosimetric verifications and to assess possible corre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964449

    authors: Trnková P,Bolsi A,Albertini F,Weber DC,Lomax AJ

    更新日期:2016-11-01 00:00:00

  • Characterization of tissue-specific pre-log Bayesian CT reconstruction by texture-dose relationship.

    abstract:PURPOSE:Tissue textures have been recognized as biomarkers for various clinical tasks. In computed tomography (CT) image reconstruction, it is important but challenging to preserve the texture when lowering x-ray exposure from full- toward low-/ultra-low dose level. Therefore, this paper aims to explore the texture-dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14449

    authors: Gao Y,Liang Z,Xing Y,Zhang H,Pomeroy M,Lu S,Ma J,Lu H,Moore W

    更新日期:2020-10-01 00:00:00

  • SU-F-BRCD-06: Multiple Anatomy Optimization of Accumulated Dose.

    abstract:PURPOSE:Multiple anatomy optimization (MAO) utilizing deformable dose accumulation on entire 4DCT data sets is implemented to overcome ambiguity between optimal dose defined on a single anatomy and optimal accumulated dose resulting from dose delivery to moving and deforming anatomy. METHODS:Six lung cancer patients a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735744

    authors: Watkins WT,Moore JA,Sharma M,Dial C,Xu H,Hugo GD,Gordon JJ,Siebers JV

    更新日期:2012-06-01 00:00:00

  • SU-E-J-41: Fluoroscopy Based Adaptive Setup Approach for Thoracic Cancer IGRT.

    abstract:PURPOSE:To develop a fluoroscopy imaging based approach that can determine the magnitude and phase variation in respiratory motion against the treatment planning images in order to quantify the online patient setup deviation in thoracic cancer IGRT for the real time adaptive patient positionadjustment. METHODS:A numer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734876

    authors: Chen T,Qin S,Jabbour S,Park J,Haffty B,Yue N

    更新日期:2012-06-01 00:00:00

  • Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram.

    abstract:PURPOSE:The aim of this work is to investigate the predictive power of a common conventional intensity modulated radiation therapy (IMRT) quality assurance (QA) performance metric, the gamma passing rate (%GP), through the analysis of the sensitivity and of the correlation between %GP and different dose discrepancies b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767763

    authors: Stasi M,Bresciani S,Miranti A,Maggio A,Sapino V,Gabriele P

    更新日期:2012-12-01 00:00:00

  • Examination of a deformable motion model for respiratory movements and 4D dose calculations using different driving surrogates.

    abstract:PURPOSE:The aim of this study was to evaluate a surrogate-driven motion model based on four-dimensional computed tomography that is able to predict CT volumes corresponding to arbitrary respiratory phases. Furthermore, the comparison of three different driving surrogates is examined and the feasibility of using the mod...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12243

    authors: Wölfelschneider J,Seregni M,Fassi A,Ziegler M,Baroni G,Fietkau R,Riboldi M,Bert C

    更新日期:2017-06-01 00:00:00

  • Fast IMRT with narrow high energy scanned photon beams.

    abstract:PURPOSE:Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3615059

    authors: Andreassen B,Strååt SJ,Holmberg R,Näfstadius P,Brahme A

    更新日期:2011-08-01 00:00:00

  • Leakage and scatter radiation from a double scattering based proton beamline.

    abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2805086

    authors: Moyers MF,Benton ER,Ghebremedhin A,Coutrakon G

    更新日期:2008-01-01 00:00:00

  • Application of radiomics for the prediction of HPV status for patients with head and neck cancers.

    abstract:PURPOSE:To perform radiomic analysis of primary tumors extracted from pretreatment contrast-enhanced computed tomography (CE-CT) images for patients with oropharyngeal cancers to identify discriminant features and construct an optimal classifier for the characterization and prediction of human papilloma virus (HPV) sta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13977

    authors: Bagher-Ebadian H,Lu M,Siddiqui F,Ghanem AI,Wen N,Wu Q,Liu C,Movsas B,Chetty IJ

    更新日期:2020-02-01 00:00:00

  • Clinical implementation and commissioning of the MedAustron Particle Therapy Accelerator for non-isocentric scanned proton beam treatments.

    abstract:PURPOSE:This paper describes the clinical implementation and medical commissioning of the MedAustron Particle Therapy Accelerator (MAPTA) for non-isocentric scanned proton beam treatments. METHODS:Medical physics involvement during technical commissioning work is presented. Acceptance testing procedures, including adv...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13928

    authors: Grevillot L,Osorio Moreno J,Letellier V,Dreindl R,Elia A,Fuchs H,Carlino A,Kragl G,Palmans H,Vatnitsky S,Stock M

    更新日期:2020-02-01 00:00:00

  • Motion tracking in the liver: validation of a method based on 4D ultrasound using a nonrigid registration technique.

    abstract:PURPOSE:Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4890091

    authors: Vijayan S,Klein S,Hofstad EF,Lindseth F,Ystgaard B,Langø T

    更新日期:2014-08-01 00:00:00

  • SU-E-T-04: Repair Kinetics of Sublethal Damage in Rat Cervical Spinal Cord - Application of the GLQ Model Incorporating Reciprocal Time Pattern.

    abstract:PURPOSE:The repair rate conventionally assumed to be constant during the entire radiation course. However, increasing evidences from animal studies show that the repair process may slow down with time and the experimental data does not fit an exponential pattern. To address this enigma, we presented a generalized linea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735058

    authors: Huang Z,Mayr NA,Lo SS,McLawhorn R,Gao M,Liu T,Yuh W

    更新日期:2012-06-01 00:00:00

  • On the constancy in composition of polystyrene and polymethylmethacrylate plastics.

    abstract::Variations in the atomic composition, and mass and electron densities of polystyrene and polymethylmethacrylate (PMM) plastics were assessed from experimentally determined mass attenuation coefficients for 125I and 137Cs gamma rays. The means and standard deviations in the mass densities of 16 samples of PMM and 10 sa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594528

    authors: Schulz RJ,Nath R

    更新日期:1979-03-01 00:00:00

  • Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET.

    abstract::The GEANT4 application for tomographic emission (GATE) is one of the most detailed Monte Carlo simulation tools for SPECT and PET. It allows for realistic phantoms, complex decay schemes, and a large variety of detector geometries. However, only a fraction of the information in each particle history is available for p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3078045

    authors: De Beenhouwer J,Staelens S,Vandenberghe S,Verhaeghe J,Van Holen R,Rault E,Lemahieu I

    更新日期:2009-04-01 00:00:00

  • Efficient generation of a magnetic field-free line.

    abstract:PURPOSE:Signal encoding in magnetic particle imaging (MPI) is achieved by moving a field-free point (FFP) through the region of interest. One way to increase the sensitivity of the method is to scan the region of interest with a field-free line (FFL) instead of the FFP. Recently, the first feasible FFL coil setup was i...

    journal_title:Medical physics

    pub_type: 信件

    doi:10.1118/1.3447726

    authors: Knopp T,Erbe M,Biederer S,Sattel TF,Buzug TM

    更新日期:2010-07-01 00:00:00

  • A framework for quantification and visualization of segmentation accuracy and variability in 3D lateral ventricle ultrasound images of preterm neonates.

    abstract:PURPOSE:Intraventricular hemorrhage (IVH) is a major cause of brain injury in preterm neonates. Three dimensional ultrasound (US) imaging systems have been developed to visualize 3D anatomical structure of preterm neonatal intracranial ventricular system with IVH and ventricular dilation. To allow quantitative analysis...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4932366

    authors: Chen Y,Qiu W,Kishimoto J,Gao Y,Chan RH,de Ribaupierre S,Fenster A,Chiu B

    更新日期:2015-11-01 00:00:00

  • Estimated spectrum of a 4-MV therapeutic beam.

    abstract::We have made a comparative investigation of the estimated spectra obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 4-MV x-ray beam. Four transform pair models currently used with this method have been evaluated. It has been determined that the Archer-Wagn...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595878

    authors: Ahuja SD,Steward PG,Roy TS,Slessinger ED

    更新日期:1986-05-01 00:00:00

  • SU-E-J-100: Feasibility of Dose Calculation Using Combined Information of Cone-Beam and Multi-Slice CT Images.

    abstract:PURPOSE:The purpose of this study is to evaluate the feasibility of kilovoltage cone-beam CT (CBCT) images that are obtained with the Varian On-Board Imager in dose calculation at each radiation therapy. METHODS:CBCT images are commonly degraded by scattered radiations originating in the patient's body, and so the CT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734936

    authors: Usui K,Ogawa K,Kunieda E

    更新日期:2012-06-01 00:00:00