A piecewise-focused high DQE detector for MV imaging.

Abstract:

PURPOSE:Electronic portal imagers (EPIDs) with high detective quantum efficiencies (DQEs) are sought to facilitate the use of the megavoltage (MV) radiotherapy treatment beam for image guidance. Potential advantages include high quality (treatment) beam's eye view imaging, and improved cone-beam computed tomography (CBCT) generating images with more accurate electron density maps with immunity to metal artifacts. One approach to increasing detector sensitivity is to couple a thick pixelated scintillator array to an active matrix flat panel imager (AMFPI) incorporating amorphous silicon thin film electronics. Cadmium tungstate (CWO) has many desirable scintillation properties including good light output, a high index of refraction, high optical transparency, and reasonable cost. However, due to the 0 1 0 cleave plane inherent in its crystalline structure, the difficulty of cutting and polishing CWO has, in part, limited its study relative to other scintillators such as cesium iodide and bismuth germanate (BGO). The goal of this work was to build and test a focused large-area pixelated "strip" CWO detector. METHODS:A 361 × 52 mm scintillator assembly that contained a total of 28 072 pixels was constructed. The assembly comprised seven subarrays, each 15 mm thick. Six of the subarrays were fabricated from CWO with a pixel pitch of 0.784 mm, while one array was constructed from BGO for comparison. Focusing was achieved by coupling the arrays to the Varian AS1000 AMFPI through a piecewise linear arc-shaped fiber optic plate. Simulation and experimental studies of modulation transfer function (MTF) and DQE were undertaken using a 6 MV beam, and comparisons were made between the performance of the pixelated strip assembly and the most common EPID configuration comprising a 1 mm-thick copper build-up plate attached to a 133 mg/cm(2) gadolinium oxysulfide scintillator screen (Cu-GOS). Projection radiographs and CBCT images of phantoms were acquired. The work also introduces the use of a lightweight edge phantom to generate MTF measurements at MV energies and shows its functional equivalence to the more cumbersome slit-based method. RESULTS:Measured and simulated DQE(0)'s of the pixelated CWO detector were 22% and 26%, respectively. The average measured and simulated ratios of CWO DQE(f) to Cu-GOS DQE(f) across the frequency range of 0.0-0.62 mm(-1) were 23 and 29, respectively. 2D and 3D imaging studies confirmed the large dose efficiency improvement and that focus was maintained across the field of view. In the CWO CBCT images, the measured spatial resolution was 7 lp/cm. The contrast-to-noise ratio was dramatically improved reflecting a 22 × sensitivity increase relative to Cu-GOS. The CWO scintillator material showed significantly higher stability and light yield than the BGO material. CONCLUSIONS:An efficient piecewise-focused pixelated strip scintillator for MV imaging is described that offers more than a 20-fold dose efficiency improvement over Cu-GOS.

journal_name

Med Phys

journal_title

Medical physics

authors

Star-Lack J,Shedlock D,Swahn D,Humber D,Wang A,Hirsh H,Zentai G,Sawkey D,Kruger I,Sun M,Abel E,Virshup G,Shin M,Fahrig R

doi

10.1118/1.4927786

subject

Has Abstract

pub_date

2015-09-01 00:00:00

pages

5084-99

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • SU-E-T-622: A Rapid Hybrid VMAT-IMRT Planning Method Using an Abbreviated Beam Angle Optimization Search.

    abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735712

    authors: Schulze D,Ionascu D,Tyagi N

    更新日期:2012-06-01 00:00:00

  • Optimal shielding design for bunkers of compact cyclotrons used in the production of medical radionuclides.

    abstract:PURPOSE:There are several options to consider in the design of a vault that will house a cyclotron for radioisotopes production with regards to the door entrance. Alternatives are a direct-shielded door, a simple maze, or a double-legged maze. In this work, the impact of the neutron and photon doses at the vault entran...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3515458

    authors: Facure A,França WF

    更新日期:2010-12-01 00:00:00

  • Transcranial phase aberration correction using beam simulations and MR-ARFI.

    abstract:PURPOSE:Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-AR...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4865778

    authors: Vyas U,Kaye E,Pauly KB

    更新日期:2014-03-01 00:00:00

  • VMAT and IMRT plan-specific correction factors for linac-based ionization chamber dosimetry.

    abstract:PURPOSE:The determination of absorbed dose to water from external beam radiotherapy using radiation detectors is currently rooted in calibration protocols that do not account for modulations encountered in patient-specific deliveries. Detector response in composite clinical fields has not been extensively studied due t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13293

    authors: Desai VK,Labby ZE,Hyun MA,DeWerd LA,Culberson WS

    更新日期:2019-02-01 00:00:00

  • Optimization of power deposition and a heating strategy for external ultrasound thermal therapy.

    abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406516

    authors: Lin WL,Liang TC,Yen JY,Liu HL,Chen YY

    更新日期:2001-10-01 00:00:00

  • Leakage and scatter radiation from a double scattering based proton beamline.

    abstract::Proton beams offer several advantages over conventional radiation techniques for treating cancer and other diseases. These advantages might be negated if the leakage and scatter radiation from the beamline and patient are too large. Although the leakage and scatter radiation for the double scattering proton beamlines ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2805086

    authors: Moyers MF,Benton ER,Ghebremedhin A,Coutrakon G

    更新日期:2008-01-01 00:00:00

  • Techniques to alleviate the effects of view aliasing artifacts in computed tomography.

    abstract::Due to practical limitations in data acquisition, 3-D computed tomography systems must attempt to provide rapid reconstructions of acceptable quality from a limited number of views. The use of convolution backprojection (CBP) for image reconstruction from an inadequate number of projections, results in view aliasing a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598606

    authors: Galigekere RR,Wiesent K,Holdsworth DW

    更新日期:1999-06-01 00:00:00

  • Postal intercomparison of absorbed dose for high energy x rays with thermoluminescence dosimeters.

    abstract::This study concerns the accuracy and precision of the IAEA/WHO LiF TLD system used in intercomparison by mail of absorbed doses from 60Co gamma-radiation and 4-25 MV x rays. The system employs 160 mg LiF powder in polystyrene capsules, which are placed at 5 or 7 cm depth in water and irradiated to doses close to 200 r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594746

    authors: Bjärngard BE,Kase KR,Rudén BI,Biggs PJ,Boyer AL,Johansson KA

    更新日期:1980-09-01 00:00:00

  • Accurate technique for complete geometric calibration of cone-beam computed tomography systems.

    abstract::Cone-beam computed tomography systems have been developed to provide in situ imaging for the purpose of guiding radiation therapy. Clinical systems have been constructed using this approach, a clinical linear accelerator (Elekta Synergy RP) and an iso-centric C-arm. Geometric calibration involves the estimation of a s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1869652

    authors: Cho Y,Moseley DJ,Siewerdsen JH,Jaffray DA

    更新日期:2005-04-01 00:00:00

  • On the use of C-arm fluoroscopy for treatment planning in high dose rate brachytherapy.

    abstract::Treatment planning for brachytherapy requires the acquisition of geometrical information of the implant applicator and the patient anatomy. This is typically done using a simulator or a computed tomography scanner. In this study, we present a different method by which orthogonal images from a C-arm fluoroscopic machin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1598851

    authors: Liu L,Bassano DA,Prasad SC,Keshler BL,Hahn SS

    更新日期:2003-09-01 00:00:00

  • Invertibility of the dual energy x-ray data transform.

    abstract:PURPOSE:The Alvarez-Macovski method extracts the x-ray energy-dependent information by expanding the attenuation coefficient as a linear combination of functions of energy multiplied by basis set coefficients. Since the basis functions are known a priori, the coefficients represent all the energy-dependent information....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13255

    authors: Alvarez RE

    更新日期:2019-01-01 00:00:00

  • Acceptance testing and quality assurance of automated scanning film densitometers used in the dosimetry of electron and photon therapy beams.

    abstract::Scanning film densitometry routinely used for obtaining dosimetric information about therapy treatment beams is subject to several sources of inaccuracies. The most significant of these are described and appropriate methods of testing are presented. This establishes the need for adequate acceptance testing followed by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595407

    authors: Holmes TW,McCullough EC

    更新日期:1983-09-01 00:00:00

  • The effects of motion on quantitative vessel measurements.

    abstract::Optimal visualization of moving structures such as the heart and coronary arteries using digital radiographic imaging systems is a difficult problem that can involve tradeoffs between temporal, spatial, and density resolution. The motion dependence of four angiographic measures of vessel dimensions is given and demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595651

    authors: Parker DL,Clayton PD,Gustafson DE

    更新日期:1985-11-01 00:00:00

  • Sparse and optimal acquisition design for diffusion MRI and beyond.

    abstract:PURPOSE:Diffusion magnetic resonance imaging (MRI) in combination with functional MRI promises a whole new vista for scientists to investigate noninvasively the structural and functional connectivity of the human brain-the human connectome, which had heretofore been out of reach. As with other imaging modalities, diffu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3700166

    authors: Koay CG,Ozarslan E,Johnson KM,Meyerand ME

    更新日期:2012-05-01 00:00:00

  • Motion tracking of low-activity fiducial markers using adaptive region of interest with list-mode positron emission tomography.

    abstract:PURPOSE:Motion compensated positron emission tomography (PET) imaging requires detecting and monitoring of patient body motion. We developed a semiautomatic list-mode method to track the three-dimensional (3D) motion of fiducial positron-emitting markers during PET imaging. METHODS:A previously developed motion tracki...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14206

    authors: Chamberland MJP,deKemp RA,Xu T

    更新日期:2020-08-01 00:00:00

  • Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.

    abstract:PURPOSE:A dosimetric system formed by Gafchromic EBT2 radiochromic film and Epson Expression 10000XL flatbed scanner was commissioned for dosimetry. In this paper, several open questions concerning the commissioning of radiochromic films for dosimetry were addressed: (a) is it possible to employ this dosimetric system ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4772075

    authors: Mendez I,Hartman V,Hudej R,Strojnik A,Casar B

    更新日期:2013-01-01 00:00:00

  • Design and evaluation of an MRI-compatible linear motion stage.

    abstract:PURPOSE:To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS:In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937780

    authors: Tavallaei MA,Johnson PM,Liu J,Drangova M

    更新日期:2016-01-01 00:00:00

  • Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship.

    abstract:PURPOSE:Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4944501

    authors: Humbert L,Hazrati Marangalou J,Del Río Barquero LM,van Lenthe GH,van Rietbergen B

    更新日期:2016-04-01 00:00:00

  • Effect of lateral boundaries on contrast functions in time-resolved transillumination measurements.

    abstract::The method of images is employed to insert the effects of the presence of a single lateral boundary on contrast functions previously derived for an infinite slab using a random walk model of photon transport. The predictions of the model for zero and extrapolated boundary conditions are compared with Monte Carlo (MC) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598687

    authors: Chernomordik V,Gandjbakhche AH,Hebden JC,Zaccanti G

    更新日期:1999-09-01 00:00:00

  • Magnetically guided capsule endoscopy.

    abstract::Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which ...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12299

    authors: Shamsudhin N,Zverev VI,Keller H,Pane S,Egolf PW,Nelson BJ,Tishin AM

    更新日期:2017-08-01 00:00:00

  • Real-time direct diaphragm tracking using kV imaging on a standard linear accelerator.

    abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13738

    authors: Hindley N,Keall P,Booth J,Shieh CC

    更新日期:2019-10-01 00:00:00

  • SU-E-T-267: Construction and Evaluation of a Neutron Wall to Shield a 15 MV Linac in a Low-Energy Vault.

    abstract:PURPOSE:To design and quantify the shielding efficacy of an inner Borated Polyethylene (BPE)wall for a 15 MV linac in a low energy vault. METHODS:A Varian TrueBeam linac with a maximum photon energy of 15 MV was installed in asmaller, preexisting vault. This vault originally housed a low-energy machine and did not hav...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735334

    authors: Speiser M,Hager F,Foster R,Solberg T

    更新日期:2012-06-01 00:00:00

  • Monte Carlo simulation of diagnostic x-ray scatter.

    abstract::A Monte Carlo method was developed and implemented to simulate x-ray photon transport. Simulations consisted of a pencil beam of monoenergetic photons with energies from 50 to 110 keV incident on water and aluminum slabs. The dependence of scatter fraction and multiple scattering on x-ray energy, scatterer thickness, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596268

    authors: Papin PJ,Rielly PS

    更新日期:1988-11-01 00:00:00

  • Tracking the dynamic seroma cavity using fiducial markers in patients treated with accelerated partial breast irradiation using 3D conformal radiotherapy.

    abstract:PURPOSE:The purpose of the present study was to perform an analysis of the changes in the dynamic seroma cavity based on fiducial markers in early stage breast cancer patients treated with accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy (3D-CRT). METHODS:A pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4788644

    authors: Yue NJ,Haffty BG,Kearney T,Kirstein L,Chen S,Goyal S

    更新日期:2013-02-01 00:00:00

  • Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

    abstract:PURPOSE:Patient-specific IMRT QA measurements are important components of processes designed to identify discrepancies between calculated and delivered radiation doses. Discrepancy tolerance limits are neither well defined nor consistently applied across centers. The AAPM TG-218 report provides a comprehensive review a...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12810

    authors: Miften M,Olch A,Mihailidis D,Moran J,Pawlicki T,Molineu A,Li H,Wijesooriya K,Shi J,Xia P,Papanikolaou N,Low DA

    更新日期:2018-04-01 00:00:00

  • Technical Note: modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies.

    abstract:PURPOSE:The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3664003

    authors: Konstantinidis AC,Olivo A,Speller RD

    更新日期:2011-12-01 00:00:00

  • Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation.

    abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13987

    authors: Wang H,Liang D,Su S,King KF,Chang Y,Liu X,Zheng H,Ying L

    更新日期:2020-04-01 00:00:00

  • Characterization and identification of spatial artifacts during 4D-CT imaging.

    abstract:PURPOSE:The purpose of this work is twofold: First, to characterize the artifacts occurring in helical 4D-CT imaging; second, to propose a method that can automatically identify the artifacts in 4D-CT images. The authors have designed a process that can automatically identify the artifacts in 4D-CT images, which may be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553556

    authors: Han D,Bayouth J,Bhatia S,Sonka M,Wu X

    更新日期:2011-04-01 00:00:00

  • FRoG: An independent dose and LETd prediction tool for proton therapy at ProBeam® facilities.

    abstract:PURPOSE:Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14417

    authors: Kopp B,Fuglsang Jensen M,Mein S,Hoffmann L,Nyström H,Falk M,Haberer T,Abdollahi A,Debus J,Mairani A

    更新日期:2020-10-01 00:00:00

  • A novel curvilinear approach for prostate seed implantation.

    abstract:PURPOSE:A new technique called "curvilinear approach" for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. METHODS:Twenty LDR prostate brachytherapy cases planned intraopera...

    journal_title:Medical physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1118/1.3694110

    authors: Podder TK,Dicker AP,Hutapea P,Darvish K,Yu Y

    更新日期:2012-04-01 00:00:00