Abstract:
:Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine.
journal_name
Med Physjournal_title
Medical physicsauthors
Shamsudhin N,Zverev VI,Keller H,Pane S,Egolf PW,Nelson BJ,Tishin AMdoi
10.1002/mp.12299subject
Has Abstractpub_date
2017-08-01 00:00:00pages
e91-e111issue
8eissn
0094-2405issn
2473-4209journal_volume
44pub_type
杂志文章,评审相关文献
MEDICAL PHYSICS文献大全abstract::Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient....
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2775667
更新日期:2007-10-01 00:00:00
abstract:PURPOSE:The GammaPod is a novel dedicated prone breast stereotactic radiosurgery (SRS) device recently developed at the University of Maryland Medical Center. This device utilizes multiple rotating Co-60 sources to create highly conformal dose distributions for breast treatments, including boosts, partial breast irradi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14197
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:Two diodes which do not require correction factors for small field relative output measurements are designed and validated using experimental methodology. This was achieved by adding an air layer above the active volume of the diode detectors, which canceled out the increase in response of the diodes in small f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4894728
更新日期:2014-10-01 00:00:00
abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1898485
更新日期:2005-06-01 00:00:00
abstract::Coherent-scatter computed tomography (CSCT) is a novel imaging method we are developing to produce cross-sectional images based on the low-angle (<10 degrees) scatter properties of tissue. At diagnostic energies, this scatter is primarily coherent with properties dependent upon the molecular structure of the scatterer...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1493216
更新日期:2002-08-01 00:00:00
abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735203
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735220
更新日期:2012-06-01 00:00:00
abstract::Three types of iterative algorithms, algebraic inverse treatment planning (AITP), simultaneous iterative inverse treatment planning (SIITP), and iterative least-square inverse treatment planning (ILSITP), differentiated according to their updating sequences, were generalized to three dimension with true beam geometry ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598374
更新日期:1998-10-01 00:00:00
abstract:PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4769428
更新日期:2013-01-01 00:00:00
abstract:PURPOSE:To review the issues a physicist may encounter in a community hospital during the transition from film/paper charts to a paperless environment with ARIA and a TrueBeam LINAC. With a lean budget, it was necessary for the physics group to take on the project management responsibilities in order save costs. This w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735291
更新日期:2012-06-01 00:00:00
abstract::Depth dose characteristics of 24-MV beams from a medical linear accelerator at various SSDs have been measured. The dose buildup, percent depth dose (PDD), and output were measured using ionization chambers and a diode detector under full scatter. Surface dose ranged from 8% to 51% depending upon the collimator settin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596673
更新日期:1991-03-01 00:00:00
abstract::The output factor for a therapy photon beam is defined as the dose per monitor unit relative to the dose per monitor unit in a reference field. Convolution models for photon dose calculations yield the dose in units normalized to the incident energy fluence with phantom scatter intrinsically modeled. Output factors ca...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596859
更新日期:1992-03-01 00:00:00
abstract:PURPOSE:Deformable registration generally relies on the assumption that the sought spatial transformation is smooth. Yet, breathing motion involves sliding of the lung with respect to the chest wall, causing a discontinuity in the motion field, and the smoothness assumption can lead to poor matching accuracy. In respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3679009
更新日期:2012-02-01 00:00:00
abstract::Two acrylic cube phantoms have been constructed for BNCT applications that allow the depth distribution of neutrons to be measured with miniature 10BF3 detectors in 0.5-cm steps beginning at 1-cm depth. Sizes and weights of the cubes are 14 cm, 3.230 kg, and 11 cm, 1.567 kg. Tests were made with the epithermal neutron...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598354
更新日期:1998-09-01 00:00:00
abstract::Effects of changes in the physics of EGSnrc compared to EGS4/PRESTA on energy deposition kernels for monoenergetic photons and on dose point kernels for beta sources in water are investigated. In the diagnostic energy range, Compton binding corrections were found to increase the primary energy fraction up to 4.5% at 3...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1861412
更新日期:2005-03-01 00:00:00
abstract:PURPOSE:Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be fu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948498
更新日期:2016-06-01 00:00:00
abstract::The effects of small cavities on dose in water and the dose in a homogeneous nonunit density medium illustrate that inhomogeneities do not act independently in photon dose perturbation, and serve as two constraints which should be satisfied by approximate methods of computed tomography (CT) pixel-based dose calculatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595294
更新日期:1983-03-01 00:00:00
abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735237
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging sys...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4901551
更新日期:2014-12-01 00:00:00
abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2786864
更新日期:2007-11-01 00:00:00
abstract::We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1737492
更新日期:2004-06-01 00:00:00
abstract::The hybrid algorithms developed recently for the reconstruction of fan-beam images possess computational and noise properties superior to those of the fan-beam filtered backprojection (FFBP) algorithm. However, the hybrid algorithms cannot be applied directly to a halfscan fan-beam sinogram because they require knowle...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1288239
更新日期:2000-09-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597412
更新日期:1994-10-01 00:00:00
abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897567
更新日期:2014-11-01 00:00:00
abstract::Results of an 18-alternative forced-choice experiment have shown that observers were capable of detecting a signal with a contrast of 1 in terms of 10-bit data which were displayed on a CRT monitor with an 8-bit video generator and a window width setting of 1024. We investigated the conditions under which 10-bit signa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595919
更新日期:1986-05-01 00:00:00
abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4800802
更新日期:2013-05-01 00:00:00
abstract::Although x-ray computed tomography (CT) has been in clinical use for over 3 decades, spectral optimization has not been a topic of great concern; high voltages around 120 kV have been in use since the beginning of CT. It is the purpose of this study to analyze, in a rigorous manner, the energies at which the patient d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3075901
更新日期:2009-03-01 00:00:00
abstract::The photon response of silicon-diode neutron detectors is analyzed theoretically and measured in the 15-25-MeV region. The main mechanism for producing a response in the diode is shown to be the displacement of silicon atoms by scattering of electrons. If the photon source is an electron accelerator target, the respon...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594403
更新日期:1978-01-01 00:00:00
abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13417
更新日期:2019-04-01 00:00:00
abstract:PURPOSE:To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS:In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930798
更新日期:2015-10-01 00:00:00