Quantum noise in detectors.

Abstract:

:The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribution in the number of x-ray photons absorbed by a detector. The standard deviation (quantum noise) in this distribution is very well approximated by the commonly used and experimentally verified quantity square root N where N is the average number of x-ray number of x-ray photons absorbed by the detector.

journal_name

Med Phys

journal_title

Medical physics

authors

Rimkus D,Baily NA

doi

10.1118/1.595393

subject

Has Abstract

pub_date

1983-07-01 00:00:00

pages

470-1

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

10

pub_type

杂志文章
  • SU-E-I-94: External Beam Radiation Cherenkov Emission in Tissue Used for Tissue Oxygen Sensing.

    abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734811

    authors: Zhang R,Kanick S,Vinogradov S,Esipova T,Pogue B

    更新日期:2012-06-01 00:00:00

  • Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation.

    abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14676

    authors: Ma J,Wang Y,An X,Ge C,Yu Z,Chen J,Zhu Q,Dong G,He J,He Z,Cao T,Zhu Y,Nie Z,Yang X

    更新日期:2020-12-23 00:00:00

  • Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging.

    abstract:PURPOSE:The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4957389

    authors: So A,Imai Y,Nett B,Jackson J,Nett L,Hsieh J,Wisenberg G,Teefy P,Yadegari A,Islam A,Lee TY

    更新日期:2016-08-01 00:00:00

  • Photon-beam subsource sensitivity to the initial electron-beam parameters.

    abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1884385

    authors: Fix MK,Keall PJ,Siebers JV

    更新日期:2005-04-01 00:00:00

  • The water-equivalence of phantom materials for 90Sr-90Y beta particles.

    abstract::Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1376176

    authors: Buckley LA,Thomadsen BR,DeWerd LA

    更新日期:2001-06-01 00:00:00

  • Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams.

    abstract:PURPOSE:Dose verification in highly conformal radiation therapy such as IMRT or proton therapy can benefit from the high spatial resolution offered by radio-chromic films such as Gafchromic EBT or EBT2. Recently, a new generation of these films, EBT3, has become available. The composition and thickness of the sensitive...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737890

    authors: Reinhardt S,Hillbrand M,Wilkens JJ,Assmann W

    更新日期:2012-08-01 00:00:00

  • Toward consensus on quantitative assessment of medical imaging systems.

    abstract::Consensus has been developing over the past few decades on a number of measurements required for the laboratory assessment of medical imaging modalities. Nevertheless, understanding of the connection between these measurements and human observer performance in a broad range of tasks remains far from complete. Focusing...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.597511

    authors: Metz CE,Wagner RF,Doi K,Brown DG,Nishikawa RM,Myers KJ

    更新日期:1995-07-01 00:00:00

  • Predicting 3D body shape and body composition from conventional 2D photography.

    abstract:PURPOSE:Total and regional body composition are important indicators of health and mortality risk, but their measurement is usually restricted to controlled environments in clinical settings with expensive and specialized equipment. A method that approaches the accuracy of the current gold standard method, dual-energy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14492

    authors: Tian IY,Ng BK,Wong MC,Kennedy S,Hwaung P,Kelly N,Liu E,Garber AK,Curless B,Heymsfield SB,Shepherd JA

    更新日期:2020-12-01 00:00:00

  • Stress analysis using anatomically realistic coronary tree.

    abstract::Plaque rupture with superimposed thrombosis is the main cause of the acute coronary syndromes of unstable angina, myocardial infarction, and sudden death. Endothelial disruption leading to plaque rupture may relate to mechanical fatigue associated with cyclic flexion of plaques. A novel method is proposed to assess st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1593635

    authors: Wu HC,Chen SY,Shroff SG,Carroll JD

    更新日期:2003-11-01 00:00:00

  • An anthropomorphic torso section phantom for ultrasonic imaging.

    abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594657

    authors: Madsen EL,Zagzebski JA,Ghilardi-Netto T

    更新日期:1980-01-01 00:00:00

  • Experimental study of humidity effect on charge measurement of reference ionization chambers in clinical high-energy photon beams.

    abstract:PURPOSE:In the practice code of dosimetry, humidity effect is assumed to be constant as far as the measurements are performed in the relative humidity (RH) range of (20-80)%; thus, the humidity effect can be ignored with a dose uncertainty of 0.15%. This assumption is based on the previous experimental results by Niate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13665

    authors: Sato Y,Shimizu M,Morishita Y,Sato M,Hoshina M

    更新日期:2019-09-01 00:00:00

  • SU-E-T-504: Incident Fluence Reconstruction Based on Monte Carlo Finite-Size Pencil Beam Model for Dose Guided Radiation Therapy.

    abstract:PURPOSE:In dose guided radiation therapy, incident fluence is one of the important parameters for both influence verification and dose reconstruction. The objective of this investigation was to develop a method to obtain the incident fluence for dose reconstruction in dose guided radiation therapy (DGRT). METHODS:An i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735593

    authors: Li G,Wu Y,FDS Team.

    更新日期:2012-06-01 00:00:00

  • Voxel clustering for quantifying PET-based treatment response assessment.

    abstract:PURPOSE:Imaging biomarkers are crucial in managing treatment options for cancer patients. They are extremely powerful tools since they allow personalized treatment assessment early during therapy by using repeated imaging to detect and quantify tumor response. Currently, treatment response assessment from consecutive i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764900

    authors: Schreibmann E,Waller AF,Crocker I,Curran W,Fox T

    更新日期:2013-01-01 00:00:00

  • Design and evaluation of an MRI-compatible linear motion stage.

    abstract:PURPOSE:To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS:In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937780

    authors: Tavallaei MA,Johnson PM,Liu J,Drangova M

    更新日期:2016-01-01 00:00:00

  • Evaluation of the 4D RADPOS dosimetry system for dose and position quality assurance of CyberKnife.

    abstract:PURPOSE:The Synchrony respiratory motion tracking of the CyberKnife system purports to provide real-time tumor motion compensation during robotic radiosurgery. Such a complex delivery system requires thorough quality assurance. In this work, RADPOS applicability as a dose and position quality assurance tool for CyberKn...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13102

    authors: Marants R,Vandervoort E,Cygler JE

    更新日期:2018-07-25 00:00:00

  • Poster - Thurs Eve-04: Mathematical modeling of liver metastases tumour growth and control with radiotherapy.

    abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965923

    authors: Campbell A,Davidson M,Lock M,Wong E

    更新日期:2008-07-01 00:00:00

  • Measurement of the replacement correction factor for parallel-plate chambers in electron fields.

    abstract::When parallel-plate chambers are used for dosimetry in electron fields, the AAPM dosimetry protocol recommends a value of 1.0 for the replacement correction factor, P(repl),pp,E, until further data become available. Here, P(repl),pp,E for five commercially available parallel-plate chambers was measured as a function o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596740

    authors: Reft CS,Kuchnir FT

    更新日期:1991-11-01 00:00:00

  • The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy.

    abstract::Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812851

    authors: Bergman AM,Otto K,Duzenli C

    更新日期:2004-12-01 00:00:00

  • AAPM Task Group 329: Reference dose specification for dose calculations: Dose-to-water or dose-to-muscle?

    abstract::Linac calibration is done in water, but patients are comprised primarily of soft tissue. Conceptually, and specified in NRG/RTOG trials, dose should be reported as dose-to-muscle to describe the dose to the patient. Historically, the dose-to-water of the linac calibration was often converted to dose-to-muscle for pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13995

    authors: Kry SF,Feygelman V,Balter P,Knöös T,Charlie Ma CM,Snyder M,Tonner B,Vassiliev ON

    更新日期:2020-03-01 00:00:00

  • Comparison of three strategies in management of independent movement of the prostate and pelvic lymph nodes.

    abstract:PURPOSE:Concurrent irradiation of the prostate and pelvic lymph nodes is technically challenging due to treating one moving target and one immobile target. The purposes of this article are to propose a new management strategy and to compare this strategy to the conventional isocenter shift method and the previously pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3480505

    authors: Xia P,Qi P,Hwang A,Kinsey E,Pouliot J,Roach M 3rd

    更新日期:2010-09-01 00:00:00

  • Simultaneous respiratory motion correction and image reconstruction in 4D-multi pinhole small animal SPECT.

    abstract:PURPOSE:Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory m...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13807

    authors: Naseri M,Rajabi H,Wang J,Abbasi M,Kalantari F

    更新日期:2019-11-01 00:00:00

  • Automatic detection of simulated motion blur in mammograms.

    abstract:PURPOSE:To use machine-learning algorithms and blur measure (BM) operators to automatically detect motion blur in mammograms. Motion blur has been reported to reduce lesion detection performance and mask small abnormalities, resulting in failure to detect them until they reach more advanced stages. Automatic detection ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14069

    authors: Kamona N,Loew M

    更新日期:2020-04-01 00:00:00

  • The use of a priori information in the detection of mammographic microcalcifications to improve their classification.

    abstract::In this work, we present a calcification-detection scheme that automatically localizes calcifications in a previously detected cluster in order to generate the input for a cluster-classification scheme developed in the past. The calcification-detection scheme makes use of three pieces of a priori information: the loca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1559884

    authors: Salfity MF,Nishikawa RM,Jiang Y,Papaioannou J

    更新日期:2003-05-01 00:00:00

  • The role of water desorption on optical clearing of biotissue: studied with near infrared reflectance spectroscopy.

    abstract::In order to understand the role of water desorption, i.e., the opposite of water adsorption, in optical clearing of biological tissue created by the application of hyperosmotic agents, dynamics of water loss in fresh porcine muscle tissue administrated with glycerol or ethylene glycol was investigated with the near-in...

    journal_title:Medical physics

    pub_type:

    doi:10.1118/1.1576228

    authors: Xu X,Wang RK

    更新日期:2003-06-01 00:00:00

  • Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging.

    abstract:PURPOSE:The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892174

    authors: Cho HM,Barber WC,Ding H,Iwanczyk JS,Molloi S

    更新日期:2014-09-01 00:00:00

  • Thermal limits on MV x-ray production by bremsstrahlung targets in the context of novel linear accelerators.

    abstract:PURPOSE:To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high-dose-rate x-ray irradiation in the context of novel linear accelerators capab...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12615

    authors: Wang J,Trovati S,Borchard PM,Loo BW Jr,Maxim PG,Fahrig R

    更新日期:2017-12-01 00:00:00

  • Quantitative ionization chamber alignment to a water surface: Theory and simulation.

    abstract:PURPOSE:To examine the response properties of cylindrical cavity ionization chambers (ICs) in the depth-ionization buildup region so as to obtain a robust chamber-signal - based method for definitive water surface identification, hence absolute ionization chamber depth localization. METHOD & MATERIALS:An analytical mo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12319

    authors: Siebers JV,Ververs JD,Tessier F

    更新日期:2017-07-01 00:00:00

  • Quantification of breast density with dual energy mammography: a simulation study.

    abstract::Breast density, the percentage of glandular breast tissue, has been identified as an important yet underutilized risk factor in the development of breast cancer. A quantitative method to measure breast density with dual energy imaging was investigated using a computer simulation model. Two configurations to measure br...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3002308

    authors: Ducote JL,Molloi S

    更新日期:2008-12-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Effects of finite angular steps and extent of profile data on the calculation of rotational x-ray dose distributions.

    abstract::Computer algorithms for rotational therapy beams, in most cases, perform dose calculations by summing stored fixed beam data at finite angular steps. Such an algorithm, based on the Bentley beam model, was evaluated by comparing calculations with measured data for an 18-MV x-ray beam. Measurements were made in a speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595985

    authors: Kurup RG,Hogstrom KR,Hwang CC

    更新日期:1987-11-01 00:00:00