Abstract:
:A clamp-on current probe utilizing the Hall effect was used to determine x-ray tube current. This noninvasive technique was compared to two other methods of mA measurement: the Machlett Dynalyzer and the mR/mAs linearity method. Three diagnostic x-ray units were used in the comparison; two modern three-phase rooms and one 25 year old single-phase room. The Dynalyzer and current probe measurements agreed to within +/- 3% and showed mA miscalibration at several technique settings. The mR/mAs linearity method failed to detect any miscalibration. One disadvantage of using the current probe is its susceptibility to electronic noise when making measurements of tube current below 100 mA. These results justify the use of the current probe in routine quality control calibration checks.
journal_name
Med Physjournal_title
Medical physicsauthors
Atherton JV,Nickoloff ELdoi
10.1118/1.596080subject
Has Abstractpub_date
1987-03-01 00:00:00pages
258-61issue
2eissn
0094-2405issn
2473-4209journal_volume
14pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To investigate a novel locally adaptive projection space denoising algorithm for low-dose CT data. METHODS:The denoising algorithm is based on bilateral filtering, which smooths values using a weighted average in a local neighborhood, with weights determined according to both spatial proximity and intensity si...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3232004
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:Cone-beam CT (CBCT) images contain severe shading artifacts mostly due to scatter. Many algorithms have been proposed to alleviate this problem by data correction on projections. Sophisticated methods have also been designed to further improve the image quality when prior patient information is available. In th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736218
更新日期:2012-06-01 00:00:00
abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2739805
更新日期:2007-07-01 00:00:00
abstract:PURPOSE:This study aims to measure the surface dose on an anthropomorphic phantom for intensity-modulated radiation therapy (IMRT) plans treated in a 1.5 T magnetic resonance (MR)-Linac. Previous studies have used Monte Carlo programs to simulate surface dose and have recognized high surface dose as a potential limitin...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14185
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4926551
更新日期:2015-08-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597228
更新日期:1994-12-01 00:00:00
abstract::An easy-to-use phantom has been constructed for checking the accuracy of a stereotactic computed tomography localization system. This phantom has been used on a commercially available stereotactic radiosurgery system. With this system, the phantom reference point, whose location is established by means of a precision ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597034
更新日期:1993-03-01 00:00:00
abstract:PURPOSE:The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 μm pixel pitch and 300 μm thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 μm pixel pit...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792460
更新日期:2013-03-01 00:00:00
abstract::Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unst...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461840
更新日期:2002-04-01 00:00:00
abstract::Gd2O2S phosphor screens between 250 and 1000 mg/cm2 thick were evaluated for use in megavoltage imaging systems. The phosphor layers were placed on brass plates ranging from 1 to 5 mm thick, each with and without an optical back reflector (white paint). Light output and spatial resolution were measured at 6- and 23-MV...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597209
更新日期:1994-08-01 00:00:00
abstract:PURPOSE:Measured values of ultrasound attenuation in bone represent a combination of different loss mechanisms. As a wave is transmitted from a fluid into bone, reflections occur at the interface. In the bone, mode conversion occurs between longitudinal and shear modes and the mechanical wave is scattered by its comple...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3668316
更新日期:2012-01-01 00:00:00
abstract::Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1774131
更新日期:2004-09-01 00:00:00
abstract:PURPOSE:To evaluate dosimetric variations of planning target volume (PTV) on critical organs such as rectal wall, bladder and femoral head, when the patient size changes due to weight loss in prostate volumetric modulated arc therapy (VMAT). METHODS:Three patients with small (32.0 cm3 ), medium (48.4 cm3 ) and large (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735610
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14208
更新日期:2020-08-01 00:00:00
abstract::A formalism for an independent dose verification of the Gamma Knife treatment planning is developed. It is based on the approximation that isodose distribution for a single shot is in the shape of an ellipsoid in three-dimensional space. The dose profiles for a phantom along each of the three major axes are fitted to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1501139
更新日期:2002-09-01 00:00:00
abstract:PURPOSE:Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the hi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4752211
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:On-board MRI can provide superb soft tissue contrast for improving liver SBRT localization. However, the availability of on-board MRI in clinics is extremely limited. On the contrary, on-board kV imaging systems are widely available on radiotherapy machines, but its capability to localize tumors in soft tissue ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12998
更新日期:2018-07-01 00:00:00
abstract::Currently, patients with brain neoplasms must undergo both computed tomography (CT) and magnetic resonance (MR) imaging to take advantage of CT's density information and MR's soft tissue imaging capabilities. A method has been developed that allows virtual simulation, digitally reconstructed radiographs (DRRs), and 3-...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598382
更新日期:1998-10-01 00:00:00
abstract::A new type of radiographic film, EDR (extended dose range) film, has been recently become available for film dosimetry. It is particularly attractive for composite isodose verification of intensity modulated radiation therapy because of its low sensitivity relative to the more common Kodak XV film. For XV film, the re...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1568979
更新日期:2003-05-01 00:00:00
abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735574
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To demonstrate an objective approach to determining if a negative report from the Radiological Physics Center (RPC) of greater than 10% error is valid or has clinical significance. METHODS:The discrepancy involved the clinical activity (mgRaEq) of Cs-137 sources, some manufactured by 3M and some by Amersham. M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735271
更新日期:2012-06-01 00:00:00
abstract::Topographic treatment is a radiation therapy delivery technique for fixed-gantry (nonrotational) treatments on a helical tomotherapy system. The intensity-modulated fields are created by moving the treatment couch relative to a fan-beam positioned at fixed gantry angles. The delivered dose distribution is controlled b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2216876
更新日期:2006-08-01 00:00:00
abstract:PURPOSE:Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3266750
更新日期:2010-01-01 00:00:00
abstract::We have made a comparative investigation of the estimated spectra obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 4-MV x-ray beam. Four transform pair models currently used with this method have been evaluated. It has been determined that the Archer-Wagn...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595878
更新日期:1986-05-01 00:00:00
abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596487
更新日期:1990-05-01 00:00:00
abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4812429
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3426000
更新日期:2010-08-01 00:00:00
abstract:PURPOSE:To develop a real-time markerless 3D tumor tracking using kilovoltage (kV) cone-beam CT (CBCT) projection images during volumetric modulated arc therapy (VMAT) treatment of lung tumors. METHODS:The authors have developed a method to identify the position of lung tumors during VMAT treatment, where the current ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4821545
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3633941
更新日期:2011-10-01 00:00:00
abstract::By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design per...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2357020
更新日期:2006-11-01 00:00:00