Abstract:
PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. The energy conversion layer of both prototypes was made of scintillating fiber layers interleaved with corrugated lead sheets to form a honeycomb pattern. The scintillating fibers have a diameter of 1 mm and the distance between the centers of neighboring fibers on the same layer is 1.35 mm. The layers have 1.22 mm spacing between them. The energy conversion layer has a thickness of 2 cm. The modulation transfer function (MTF), antiscatter properties and sensitivity of the detector with a single pixel readout were measured using a 6-MV beam on a LINAC machine. In addition, a Monte Carlo simulation was conducted to calculate the zero-frequency detective quantum efficiency (DQE(0)) of the proposed detector with an active matrix flat-panel imager for readout. RESULTS:The DQE(0) of the proposed detector can be 11.5%, which is about an order of magnitude higher than that of current EPIDs. The frequency of 50% modulation ( f 50 ) of the measured MTF is 0.2 mm - 1 at 6 MV, which is comparable to that of video-based EPIDs. The scatter to primary ratio (SPR) measured with the detector at 10 cm air gap and 20 × 20 cm 2 field size is approximately 30% lower than that of ionization chamber-based detectors with a comparable QE. The detector noise which includes the x-ray quantum noise and absorption noise is much larger than the electronic noise per pixel of the flat-panel imager at a dose of less than two LINAC pulses. Thus, the proposed detector is quantum noise limited down to very low doses (∼a couple of radiation pulses of the LINAC). A proof-of-concept image has been obtained using a 6-MV beam. CONCLUSIONS:This work indicates that by using scintillating fibers and lead layers it is possible to increase the thickness of the detecting materials, and therefore the QE or the DQE(0) of the detector, while maintaining an adequate spatial resolution for MV x-ray imaging. Due to the use of lead as the spacing material, the new detector also has antiscatter property, which will help improve the signal-to-noise ratio of the images. Further investigation to optimize the design of the detector and achieve a better combination of DQE and spatial resolution is warranted.
journal_name
Med Physjournal_title
Medical physicsauthors
Liu J,Xu Y,Teymurazyan A,Papandreou Z,Pang Gdoi
10.1002/mp.13900subject
Has Abstractpub_date
2020-01-01 00:00:00pages
152-163issue
1eissn
0094-2405issn
2473-4209journal_volume
47pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12134
更新日期:2017-05-01 00:00:00
abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1812609
更新日期:2004-12-01 00:00:00
abstract:PURPOSE:To compare optimization characteristics, plan quality, and treatment delivery efficiency between total marrow irradiation (TMI) plans using the new TomoTherapy graphic processing unit (GPU) based dose engine and CPU/cluster based dose engine. METHODS:Five TMI plans created on an anthropomorphic phantom were op...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4810936
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:Flattening filters (FFs) have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. The reasons for the longstanding use are, however, historical ones. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have s...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.3554643
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813302
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:A new technique called "curvilinear approach" for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. METHODS:Twenty LDR prostate brachytherapy cases planned intraopera...
journal_title:Medical physics
pub_type: 杂志文章,随机对照试验
doi:10.1118/1.3694110
更新日期:2012-04-01 00:00:00
abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594679
更新日期:1980-05-01 00:00:00
abstract::Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2008467
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract::The introduction of negative pions into cancer therapy has required the construction of large new proton accelerators together with special magnetic systems to form and direct the pion beam to a patient. A summary is presented of the fundamental properties of pions and of the methods used to study the therapeutic beam...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.594868
更新日期:1981-05-01 00:00:00
abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596302
更新日期:1988-03-01 00:00:00
abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1287439
更新日期:2000-08-01 00:00:00
abstract:PURPOSE:To evaluate a model which can predict patient's Entrance Skin Exposure (ESE) from height and weight and a single kVp mR/mAs measurement for radiographic. METHODS:Patient height, weight and post exposure mAs are obtained to assess ESE based on IAEA model. Patient's thickness is obtained by assuming a cylindrica...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734825
更新日期:2012-06-01 00:00:00
abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1315317
更新日期:2000-11-01 00:00:00
abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4881096
更新日期:2014-07-01 00:00:00
abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596954
更新日期:1993-11-01 00:00:00
abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13983
更新日期:2020-03-01 00:00:00
abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1289375
更新日期:2000-09-01 00:00:00
abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597041
更新日期:1993-03-01 00:00:00
abstract::For diagnostic ultrasound imaging, as in computed tomography, a feature of prime importance is the detection of focal lesions of varying size and contrast (echo amplitude) from surrounding tissue. This study describes a new tissue-stimulating phantom which has been used to measure the threshold detection of varying co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595218
更新日期:1982-01-01 00:00:00
abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2960247
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams (¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3662911
更新日期:2011-12-01 00:00:00
abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12104
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:To assess the image quality, scatter, and leakage radiation of an integrated magnetic resonance linear accelerator (MR-LINAC or MRL) system. METHODS:A large American College of Radiology (ACR) magnetic resonance imaging (MRI) accreditation phantom was used to evaluate the MRI capabilities of the integrated MRL...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12767
更新日期:2018-03-01 00:00:00
abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1461841
更新日期:2002-04-01 00:00:00
abstract::Inherent in the line-spread function approach in modulation transfer function (MTF) determinations is the use of a microdensitometer to scan the density pattern resulting from the line exposure. In such a procedure, loss of fidelity in the distribution being scanned is expected. This loss is due in part to the use of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594187
更新日期:1975-09-01 00:00:00
abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2193689
更新日期:2006-05-01 00:00:00
abstract::To account for clinical divergent and polychromatic photon beams, we have developed kernel tilting and kernel hardening correction methods for convolution dose calculation algorithms. The new correction methods were validated by Monte Carlo simulation. The accuracy and computation time of the our kernel tilting and ke...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597960
更新日期:1997-11-01 00:00:00
abstract::The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596147
更新日期:1987-09-01 00:00:00
abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14400
更新日期:2020-10-01 00:00:00