Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

Abstract:

PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. The energy conversion layer of both prototypes was made of scintillating fiber layers interleaved with corrugated lead sheets to form a honeycomb pattern. The scintillating fibers have a diameter of 1 mm and the distance between the centers of neighboring fibers on the same layer is 1.35 mm. The layers have 1.22 mm spacing between them. The energy conversion layer has a thickness of 2 cm. The modulation transfer function (MTF), antiscatter properties and sensitivity of the detector with a single pixel readout were measured using a 6-MV beam on a LINAC machine. In addition, a Monte Carlo simulation was conducted to calculate the zero-frequency detective quantum efficiency (DQE(0)) of the proposed detector with an active matrix flat-panel imager for readout. RESULTS:The DQE(0) of the proposed detector can be 11.5%, which is about an order of magnitude higher than that of current EPIDs. The frequency of 50% modulation ( f 50 ) of the measured MTF is 0.2 mm - 1 at 6 MV, which is comparable to that of video-based EPIDs. The scatter to primary ratio (SPR) measured with the detector at 10 cm air gap and 20 × 20 cm 2 field size is approximately 30% lower than that of ionization chamber-based detectors with a comparable QE. The detector noise which includes the x-ray quantum noise and absorption noise is much larger than the electronic noise per pixel of the flat-panel imager at a dose of less than two LINAC pulses. Thus, the proposed detector is quantum noise limited down to very low doses (∼a couple of radiation pulses of the LINAC). A proof-of-concept image has been obtained using a 6-MV beam. CONCLUSIONS:This work indicates that by using scintillating fibers and lead layers it is possible to increase the thickness of the detecting materials, and therefore the QE or the DQE(0) of the detector, while maintaining an adequate spatial resolution for MV x-ray imaging. Due to the use of lead as the spacing material, the new detector also has antiscatter property, which will help improve the signal-to-noise ratio of the images. Further investigation to optimize the design of the detector and achieve a better combination of DQE and spatial resolution is warranted.

journal_name

Med Phys

journal_title

Medical physics

authors

Liu J,Xu Y,Teymurazyan A,Papandreou Z,Pang G

doi

10.1002/mp.13900

subject

Has Abstract

pub_date

2020-01-01 00:00:00

pages

152-163

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • Cascade convolutional neural networks for automatic detection of thyroid nodules in ultrasound images.

    abstract:PURPOSE:It is very important for calculation of clinical indices and diagnosis to detect thyroid nodules from ultrasound images. However, this task is a challenge mainly due to heterogeneous thyroid nodules with distinct components are similar to background in ultrasound images. In this study, we employ cascade deep co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12134

    authors: Ma J,Wu F,Jiang T,Zhu J,Kong D

    更新日期:2017-05-01 00:00:00

  • Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.

    abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812609

    authors: Niu H,Hsi WC,Chu JC,Kirk MC,Kouwenhoven E

    更新日期:2004-12-01 00:00:00

  • Dosimetric comparison of helical tomotherapy treatment plans for total marrow irradiation created using GPU and CPU dose calculation engines.

    abstract:PURPOSE:To compare optimization characteristics, plan quality, and treatment delivery efficiency between total marrow irradiation (TMI) plans using the new TomoTherapy graphic processing unit (GPU) based dose engine and CPU/cluster based dose engine. METHODS:Five TMI plans created on an anthropomorphic phantom were op...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810936

    authors: Nalichowski A,Burmeister J

    更新日期:2013-07-01 00:00:00

  • Current status and future perspective of flattening filter free photon beams.

    abstract:PURPOSE:Flattening filters (FFs) have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. The reasons for the longstanding use are, however, historical ones. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have s...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3554643

    authors: Georg D,Knöös T,McClean B

    更新日期:2011-03-01 00:00:00

  • Influence of cold walls on PET image quantification and volume segmentation: a phantom study.

    abstract:PURPOSE:Commercially available fillable plastic inserts used in positron emission tomography phantoms usually have thick plastic walls, separating their content from the background activity. These "cold" walls can modify the intensity values of neighboring active regions due to the partial volume effect, resulting in e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4813302

    authors: Berthon B,Marshall C,Edwards A,Evans M,Spezi E

    更新日期:2013-08-01 00:00:00

  • A novel curvilinear approach for prostate seed implantation.

    abstract:PURPOSE:A new technique called "curvilinear approach" for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. METHODS:Twenty LDR prostate brachytherapy cases planned intraopera...

    journal_title:Medical physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1118/1.3694110

    authors: Podder TK,Dicker AP,Hutapea P,Darvish K,Yu Y

    更新日期:2012-04-01 00:00:00

  • Calculation of 131I-ortho-iodohippurate absorbed kidney dose: a literature review.

    abstract::Extensive information has been made available relative to the physical aspects necessary for calculation of radiation absorbed dose from radiopharmaceuticals. A similar data base for the biological factors involved in these calculations has not been documented as thoroughly. The authors present an extensive literature...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594679

    authors: Flannery A,Veber J,Greenfield MA,McIntyre AB,Hamilton DR

    更新日期:1980-05-01 00:00:00

  • Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

    abstract::Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008467

    authors: Dmochowski J,Hoffmann KR,Singh V,Xu J,Nazareth DP

    更新日期:2005-09-01 00:00:00

  • Region-oriented CT image representation for reducing computing time of Monte Carlo simulations.

    abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2884854

    authors: Sarrut D,Guigues L

    更新日期:2008-04-01 00:00:00

  • The physics of cancer therapy with negative pions.

    abstract::The introduction of negative pions into cancer therapy has required the construction of large new proton accelerators together with special magnetic systems to form and direct the pion beam to a patient. A summary is presented of the fundamental properties of pions and of the methods used to study the therapeutic beam...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.594868

    authors: Richman C

    更新日期:1981-05-01 00:00:00

  • A survey of the information gained from planning treatment with a computer.

    abstract::We designed a questionnaire to be filled out by the physicist at the time of planning treatment with the aid of a computer in order to assess what was learned during the course of the planning session. We analyzed the results to gauge the impact of the 70 treatment planning sessions conducted during the one month peri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596302

    authors: Doppke KP,Goitein M

    更新日期:1988-03-01 00:00:00

  • The potential role of positron emission mammography for detection of breast cancer. A phantom study.

    abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1287439

    authors: Raylman RR,Majewski S,Wojcik R,Weisenberger AG,Kross B,Popov V,Bishop HA

    更新日期:2000-08-01 00:00:00

  • SU-E-I-108: Simple Approach to Determine Patient's Entrance Skin Exposure for Radiographic.

    abstract:PURPOSE:To evaluate a model which can predict patient's Entrance Skin Exposure (ESE) from height and weight and a single kVp mR/mAs measurement for radiographic. METHODS:Patient height, weight and post exposure mAs are obtained to assess ESE based on IAEA model. Patient's thickness is obtained by assuming a cylindrica...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734825

    authors: Maricle S,Jeutang L,Prasad G

    更新日期:2012-06-01 00:00:00

  • Comparative dosimetry of diode and diamond detectors in electron beams for intraoperative radiation therapy.

    abstract::The aim of the present study is to examine the validity of using silicon semiconductor detectors in degraded electron beams with a broad energy spectrum and a wide angular distribution. A comparison is made with diamond detector measurements, which is the dosimeter considered to give the best results provided that dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1315317

    authors: Björk P,Knöös T,Nilsson P

    更新日期:2000-11-01 00:00:00

  • Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming.

    abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881096

    authors: Maduskar P,Hogeweg L,de Jong PA,Peters-Bax L,Dawson R,Ayles H,Sánchez CI,van Ginneken B

    更新日期:2014-07-01 00:00:00

  • Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

    abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596954

    authors: Xu XL,Liow JS,Strother SC

    更新日期:1993-11-01 00:00:00

  • A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

    abstract:PURPOSE:To characterize the radiation dose and three-dimensional (3D) imaging performance of a recently developed mobile, isocentric C-arm equipped with a flat-panel detector (FPD) for intraoperative cone-beam computed tomography (CBCT) (Cios Spin 3D, Siemens Healthineers) and to identify potential improvements in 3D i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13983

    authors: Sheth NM,De Silva T,Uneri A,Ketcha M,Han R,Vijayan R,Osgood GM,Siewerdsen JH

    更新日期:2020-03-01 00:00:00

  • A two-step algorithm for predicting portal dose images in arbitrary detectors.

    abstract::Recently, portal imaging systems have been successfully demonstrated in dosimetric treatment verification applications, where measured and predicted images are quantitatively compared. To advance this approach to dosimetric verification, a two-step model which predicts dose deposition in arbitrary portal image detecto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1289375

    authors: McCurdy BM,Pistorius S

    更新日期:2000-09-01 00:00:00

  • Rare-earth scatter fractions in chest radiography.

    abstract::A beam stop technique was used to measure the densitometric scatter fractions under three regions of a humanoid chest phantom utilizing LaOBr and Gd2O2S screens. For these receptors, the scatter fractions under the lung and retrocardiac areas were 13%-36% lower than published values for CaWO4. In the mediastinal area,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597041

    authors: Petrone TJ,Steidley KD

    更新日期:1993-03-01 00:00:00

  • A contrast-detail analysis of diagnostic ultrasound imaging.

    abstract::For diagnostic ultrasound imaging, as in computed tomography, a feature of prime importance is the detection of focal lesions of varying size and contrast (echo amplitude) from surrounding tissue. This study describes a new tissue-stimulating phantom which has been used to measure the threshold detection of varying co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595218

    authors: Smith SW,Lopez H

    更新日期:1982-01-01 00:00:00

  • Deterministic photon kerma distribution based on the Boltzmann equation for external beam radiation therapy.

    abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2960247

    authors: Yuan J,Jette D,Chen W

    更新日期:2008-09-01 00:00:00

  • Dose and dose averaged LET comparison of ¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²C, ¹⁴N, and ¹⁶O ion beams forming a spread-out Bragg peak.

    abstract:PURPOSE:Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams (¹H, ⁴He, ⁶Li, ⁸Be, ¹⁰B, ¹²...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3662911

    authors: Kantemiris I,Karaiskos P,Papagiannis P,Angelopoulos A

    更新日期:2011-12-01 00:00:00

  • An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch-MLC tracking.

    abstract:PURPOSE/OBJECTIVE:Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both techniques still have residual dosimetric errors. Here, we first propose and experimentally validate a software tool to simulate couch and MLC tracking, and then use ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12104

    authors: Toftegaard J,Hansen R,Ravkilde T,Macek K,Poulsen PR

    更新日期:2017-03-01 00:00:00

  • Assessment of image quality and scatter and leakage radiation of an integrated MR-LINAC system.

    abstract:PURPOSE:To assess the image quality, scatter, and leakage radiation of an integrated magnetic resonance linear accelerator (MR-LINAC or MRL) system. METHODS:A large American College of Radiology (ACR) magnetic resonance imaging (MRI) accreditation phantom was used to evaluate the MRI capabilities of the integrated MRL...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12767

    authors: Wang J,Yung J,Kadbi M,Hwang K,Ding Y,Ibbott GS

    更新日期:2018-03-01 00:00:00

  • Effect of phantom voxelization in CT simulations.

    abstract::In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1461841

    authors: Goertzen AL,Beekman FJ,Cherry SR

    更新日期:2002-04-01 00:00:00

  • Modulation transfer function of a finite scanning microdensitometer slit.

    abstract::Inherent in the line-spread function approach in modulation transfer function (MTF) determinations is the use of a microdensitometer to scan the density pattern resulting from the line exposure. In such a procedure, loss of fidelity in the distribution being scanned is expected. This loss is due in part to the use of ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594187

    authors: Villafana T

    更新日期:1975-09-01 00:00:00

  • Differences in the lesion formation process between focused ultrasound and microwave ablations.

    abstract::The objective is to understand the differences in the lesion formation processes between microwave and high-intensity focused ultrasound (HIFU) ablation. The lesions formed by microwaves and HIFU were real-time monitored and compared using transparent tissue-mimicking phantoms at 60 and 70 W of driving electrical powe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2193689

    authors: Chen WS,Wu CC,Fang HY,Liu HL

    更新日期:2006-05-01 00:00:00

  • Correcting kernel tilting and hardening in convolution/superposition dose calculations for clinical divergent and polychromatic photon beams.

    abstract::To account for clinical divergent and polychromatic photon beams, we have developed kernel tilting and kernel hardening correction methods for convolution dose calculation algorithms. The new correction methods were validated by Monte Carlo simulation. The accuracy and computation time of the our kernel tilting and ke...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597960

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-11-01 00:00:00

  • Scanned-projection digital mammography.

    abstract::The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596147

    authors: Nishikawa RM,Mawdsley GE,Fenster A,Yaffe MJ

    更新日期:1987-09-01 00:00:00

  • Iodine quantification in limited angle tomography.

    abstract:PURPOSE:To develop and test the feasibility of a two-pass iterative reconstruction algorithm with material decomposition designed to obtain quantitative iodine measurements in digital breast tomosynthesis. METHODS:Contrast-enhanced mammography has shown promise as a cost-effective alternative to magnetic resonance ima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14400

    authors: Michielsen K,Rodríguez-Ruiz A,Reiser I,Nagy JG,Sechopoulos I

    更新日期:2020-10-01 00:00:00