Abstract:
PURPOSE:A new motion-based gated proton therapy for the treatment of orbital tumors using real-time eye-tracking system was designed and evaluated. METHODS:We developed our system by image-pattern matching, using a normalized cross-correlation technique with LabVIEW 8.6 and Vision Assistant 8.6 (National Instruments, Austin, TX). To measure the pixel spacing of an image consistently, four different calibration modes such as the point-detection, the edge-detection, the line-measurement, and the manual measurement mode were suggested and used. After these methods were applied to proton therapy, gating was performed, and radiation dose distributions were evaluated. RESULTS:Moving phantom verification measurements resulted in errors of less than 0.1 mm for given ranges of translation. Dosimetric evaluation of the beam-gating system versus nongated treatment delivery with a moving phantom shows that while there was only 0.83 mm growth in lateral penumbra for gated radiotherapy, there was 4.95 mm growth in lateral penumbra in case of nongated exposure. The analysis from clinical results suggests that the average of eye movements depends distinctively on each patient by showing 0.44 mm, 0.45 mm, and 0.86 mm for three patients, respectively. CONCLUSIONS:The developed automatic eye-tracking based beam-gating system enabled us to perform high-precision proton radiotherapy of orbital tumors.
journal_name
Med Physjournal_title
Medical physicsauthors
Shin D,Yoo SH,Moon SH,Yoon M,Lee SB,Park SYdoi
10.1118/1.4729708subject
Has Abstractpub_date
2012-07-01 00:00:00pages
4265-73issue
7eissn
0094-2405issn
2473-4209journal_volume
39pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:Stationary computed tomography (s-CT) conceptually offers several advantages over existing rotating gantry-based CT. Over the last 40 yr, s-CT has been investigated using different technological approaches. We are developing a s-CT system specifically for head/brain imaging using carbon nanotube (CNT)-based fie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14696
更新日期:2020-12-31 00:00:00
abstract:PURPOSE:Quantification of body composition plays an important role in many clinical and research applications. Radiologic imaging techniques such as Dual-energy X-ray absorptiometry (DXA), magnetic resonance imaging (MRI), and computed tomography (CT) imaging make accurate quantification of the body composition possibl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13373
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4897610
更新日期:2014-11-01 00:00:00
abstract::Administration of x-ray contrast agents during heart catheterization examination increases the absorbed radiation dose in tissue. To estimate the dose absorbed by the blood of children undergoing diagnostic heart catheterization and angiocardiography, a number of measurements and calculations were conducted. First, en...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594613
更新日期:1979-11-01 00:00:00
abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13804
更新日期:2019-11-01 00:00:00
abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1617550
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:To develop and investigate a continuous path optimization methodology to traverse prescribed non-coplanar IMRT beams with variant SADs, by orchestrating the couch and gantry movement with zero-collision, minimal patient motion consequence and machine travel time. METHODS:We convert the given collision zone def...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735996
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:For stereotactic radiosurgery (SRS), accurate evaluation of dose-volume metrics for small structures is necessary. The purpose of this study was to compare the DVH metric capabilities of five commercially available SRS DVH analysis tools (Eclipse, Elements, Raystation, MIM, and Velocity). METHODS:DICOM RTdose ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14645
更新日期:2020-12-09 00:00:00
abstract:PURPOSE:The thermoluminescence dosimeter (TLD) has desirable features including low cost, reusability, small size, and relatively low energy dependence. However, the commonly available poly-crystal TLDs (e.g., TLD-100) exhibit high interdetector variability that requires individual calibration for high detection accura...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13895
更新日期:2020-01-01 00:00:00
abstract::An improved reconstructed stereoscopic x-ray image display system, based on the principle of binocular parallax, is described. Pulse-synchronized operation of two triode x-ray tubes and one plumbicon TV camera is employed to separate the left and right images for presentation to the two eyes, respectively. The princip...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595365
更新日期:1983-09-01 00:00:00
abstract:PURPOSE:Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-u...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12580
更新日期:2017-12-01 00:00:00
abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735351
更新日期:2012-06-01 00:00:00
abstract::Interchange or transfer of radiographic techniques through measurement of penetration quality is discussed. The usefulness of this achievement is verified using an aluminum step wedge. Also, the procedure described provides a method for performance evaluation of kVp compensation on diagnostic x-ray installations. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594156
更新日期:1975-01-01 00:00:00
abstract::The purpose of this paper is to determine the correlation between dose-volume histogram (DVH) and dose wall-histogram (DWH) in the evaluation of rectal complications for prostate cancer patients treated with three-dimensional conformal radiotherapy (3D-CRT). A retrospective analysis of DVHs and DWHs of a subset of 25 ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1951427
更新日期:2005-08-01 00:00:00
abstract::The resolution has been evaluated for an experimental x-ray image intensifier employing three microchannel plates (MCPs) as the photon absorber and electron multipliers. The line spread function (LSF) was measured and used for determination of the modulation transfer function (MTF). The MTF was found to be independent...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594463
更新日期:1978-01-01 00:00:00
abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735203
更新日期:2012-06-01 00:00:00
abstract::The variance in the number of x-ray photons absorbed by a detector is derived from theoretical considerations. The distributions in the number of x-ray photons produced by the x-ray tube, transmitted through the patient, and absorbed by the detector are described. These distributions are compounded to yield a distribu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595393
更新日期:1983-07-01 00:00:00
abstract:PURPOSE:Sterile radiation reduction gloves have been widely used in the past decade to provide modest decreases in operator hand dose when the hands are placed in the field of view (FOV). While multiple publications have quantified the potential dose reduction from the use of such gloves, possible effects on the patien...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734747
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be fu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4948498
更新日期:2016-06-01 00:00:00
abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1591431
更新日期:2003-08-01 00:00:00
abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13738
更新日期:2019-10-01 00:00:00
abstract::A study of the objective imaging characteristics of a new asymmetric screen-film system is presented herein. The system is characterized by high x-ray absorption asymmetric screens, and a low-noise, high-contrast asymmetric film having near-zero crossover. Comparisons are made with the imaging characteristics of two w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597407
更新日期:1994-09-01 00:00:00
abstract:PURPOSE:The purpose of this study is to quantify the change in monthly VMAT quality assurance (QA) and determine the tests to maintain consistent delivery with a baseline. METHODS:VMAT monthly QA has been performed for over 14 months on two Elekta Synergy LINACs. A baseline was established at acceptance and the monthl...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735470
更新日期:2012-06-01 00:00:00
abstract::One of the methods currently being used to treat choroidal melanoma employs an episcleral plaque containing I-125 radioactive seeds. However, comprehensive dosimetry studies on the plaque are scarce and controversial. For this work, we use film to study the dosimetry outside the lip of the gold shield of the eye plaqu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596556
更新日期:1990-09-01 00:00:00
abstract::MR acoustic radiation force (ARF) imaging was developed for measuring tiSsue elastic properties using focused ultrasound to deliver a localized tissue motion. In this study, an imaging ultrasound transducer was mounted on the focused ultrasound transducer and ultrasound motion tracking was performed simultaneously to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3120289
更新日期:2009-06-01 00:00:00
abstract::The mixed-field dosimetry for 252Cf Applicator Tube (AT) type medical sources available from Oak Ridge National Laboratory (ORNL) has been characterized using ionization chambers, a GM counter, and Monte Carlo methods. Unlike the AAPM Task Group No. 43 (TG-43), specification of dose to muscle instead of water is recom...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598646
更新日期:1999-08-01 00:00:00
abstract:PURPOSE:The authors investigated the potential of optimized noncoplanar irradiation trajectories for volumetric modulated arc therapy (VMAT) treatments of nasopharyngeal patients and studied the trade-off between treatment plan quality and delivery time in radiation therapy. METHODS:For three nasopharyngeal patients, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4914863
更新日期:2015-05-01 00:00:00
abstract:PURPOSE:Periodic MV∕KV radiographs taken during volumetric modulated arc therapy (VMAT) for hypofractionated treatment provide guidance in intrafractional motion management. The choice of imaging frequency and timing are key components in delivering the desired dose while reducing associated overhead such as imaging do...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4742846
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:Researchers write many computer programs with unique implementations, usually requiring a great amount of effort for other researchers to learn how to install, configure, and use. Some programs require specialized hardware platforms such as GPU workstation or CPU cluster, which may not readily available for man...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735274
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861820
更新日期:2014-02-01 00:00:00