Evaluation of two methods of predicting MLC leaf positions using EPID measurements.

Abstract:

:In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positions. Thereafter leaf positions of the MLC depend on the systematic error introduced on each leaf during MLC calibration and on the accuracy of the leaf position control system (random errors). This study presents and evaluates two methods to predict the systematic errors on the leaf positions introduced during the MLC calibration. The two presented methods are based on a series of electronic portal imaging device (EPID) measurements. A comparison with film measurements showed that the EPID could be used to measure leaf positions without introducing any bias. The first method, referred to as the "central leaf method," is based on the method currently used at this center for MLC leaf calibration. It mimics the manner in which leaf calibration parameters are specified in the MLC control system and consequently is also used by other centers. The second method, a new method proposed by the authors and referred to as the "individual leaf method," involves the measurement of two positions for each leaf (-5 and +15 cm) and the interpolation and extrapolation from these two points to any other given position. The central leaf method and the individual leaf method predicted leaf positions at prescribed positions of -11, 0, 5, and 10 cm within 2.3 and 1.0 mm, respectively, with a standard deviation (SD) of 0.3 and 0.2 mm, respectively. The individual leaf method provided a better prediction of the leaf positions than the central leaf method. Reproducibility tests for leaf positions of -5 and +15 cm were performed. The reproducibility was within 0.4 mm on the same day and 0.4 mm six weeks later (1 SD). Measurements at gantry angles of 0 degrees, 90 degrees, and 270 degrees for leaf positions of -5 and +15 cm showed no significant effect of gravity. The individual leaf method could be used in various applications to improve the accuracy of radiotherapy treatment from planning to delivery. Three cases are discussed: IMRT beam verification, MLC calibration and dose calculation.

journal_name

Med Phys

journal_title

Medical physics

authors

Parent L,Seco J,Evans PM,Dance DR,Fielding A

doi

10.1118/1.2335490

subject

Has Abstract

pub_date

2006-09-01 00:00:00

pages

3174-82

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

33

pub_type

杂志文章
  • A water phantom controller for automated acquisition of linac beam parameters.

    abstract::Three-dimensional water phantoms are routinely used when acquiring the data necessary to commission medical linear accelerators. A new water phantom controller has been developed at our institution that is unique in several aspects. The water phantom controller is based on an IBM XT compatible computer. This has been ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596414

    authors: Schmid MG,Morris RL

    更新日期:1989-01-01 00:00:00

  • Technical Note: Virtual phantom analyses for preprocessing evaluation and detection of a robust feature set for MRI-radiomics of the brain.

    abstract:PURPOSE:The purpose of the paper was to use a virtual phantom to identify a set of radiomic features from T1-weighted and T2-weighted magnetic resonance imaging (MRI) of the brain which is stable to variations in image acquisition parameters and to evaluate the effect of image preprocessing on radiomic features stabili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13834

    authors: Bologna M,Corino V,Mainardi L

    更新日期:2019-11-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597228

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-12-01 00:00:00

  • Spatiotemporal filtering of MR-temperature artifacts arising from bowel motion during transurethral MR-HIFU.

    abstract:PURPOSE:Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897382

    authors: Schmitt A,Mougenot C,Chopra R

    更新日期:2014-11-01 00:00:00

  • Octavius 4D characterization for flattened and flattening filter free rotational deliveries.

    abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817482

    authors: McGarry CK,O'Connell BF,Grattan MW,Agnew CE,Irvine DM,Hounsell AR

    更新日期:2013-09-01 00:00:00

  • A new approach to CT pixel-based photon dose calculations in heterogeneous media.

    abstract::The effects of small cavities on dose in water and the dose in a homogeneous nonunit density medium illustrate that inhomogeneities do not act independently in photon dose perturbation, and serve as two constraints which should be satisfied by approximate methods of computed tomography (CT) pixel-based dose calculatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595294

    authors: Wong JW,Henkelman RM

    更新日期:1983-03-01 00:00:00

  • GLAaS: an absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications.

    abstract::A new calibration algorithm (GLAaS) to derive absolute dose maps from images acquired with the Varian PV-aS500 electronic portal imager (based on amorphous silicon detectors) has been developed incorporating the dependence of detector response on primary and transmitted radiation and on field size. Detector calibratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2218314

    authors: Nicolini G,Fogliata A,Vanetti E,Clivio A,Cozzi L

    更新日期:2006-08-01 00:00:00

  • Attention-aware fully convolutional neural network with convolutional long short-term memory network for ultrasound-based motion tracking.

    abstract:PURPOSE:One of the promising options for motion management in radiation therapy (RT) is the use of LINAC-compatible robotic-arm-mounted ultrasound imaging system due to its high soft tissue contrast, real-time capability, absence of ionizing radiation, and low cost. The purpose of this work is to develop a novel deep l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13510

    authors: Huang P,Yu G,Lu H,Liu D,Xing L,Yin Y,Kovalchuk N,Xing L,Li D

    更新日期:2019-05-01 00:00:00

  • Technical Note: A proposal of air ventilation system design criteria for a clinical room in a heavy-ion medical facility.

    abstract:PURPOSE:An optimized air ventilation system design for a treatment room in Heavy-ion Medical Facility is an important issue in the aspects of nuclear safety because the activated air produced in a treatment room can directly affect the medical staff and the general public in the radiation-free area. METHODS:Optimized ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12914

    authors: Kum O

    更新日期:2018-06-01 00:00:00

  • Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.

    abstract:PURPOSE:Ablative hyperthermia (>55 °C) has been used as a definitive treatment for accessible solid tumors not amenable to surgery, whereas mild hyperthermia (40-45 °C) has been shown effective as an adjuvant for both radiotherapy and chemotherapy. An optimal mild hyperthermia treatment is spatially accurate, with prec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4769116

    authors: Partanen A,Tillander M,Yarmolenko PS,Wood BJ,Dreher MR,Kohler MO

    更新日期:2013-01-01 00:00:00

  • Monte Carlo dose calculations for a new ovoid shield system for carcinoma of the uterine cervix.

    abstract::The dose distribution for an ovoid with a new tungsten shielding design was determined using Monte Carlo simulation. Standard Cesium-137 tube sources, tungsten shielding, and aluminum ovoid applicator were each modeled as a collection of solid objects. Dose was calculated in planes above, below, in front of, and on th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598459

    authors: Weeks KJ

    更新日期:1998-12-01 00:00:00

  • Comparison of CBCT-based dose calculation methods in head and neck cancer radiotherapy: from Hounsfield unit to density calibration curve to deep learning.

    abstract:PURPOSE:Anatomical variations occur during head and neck (H&N) radiotherapy treatment. kV cone-beam computed tomography (CBCT) images can be used for daily dose monitoring to assess dose variations owing to anatomic changes. Deep learning methods (DLMs) have recently been proposed to generate pseudo-CT (pCT) from CBCT ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14387

    authors: Barateau A,De Crevoisier R,Largent A,Mylona E,Perichon N,Castelli J,Chajon E,Acosta O,Simon A,Nunes JC,Lafond C

    更新日期:2020-10-01 00:00:00

  • The effects of the imaging system on the validity limits of the ray-optical approach to phase contrast imaging.

    abstract::A theoretical analysis of the x-ray phase contrast imaging and its validation via synchrotron radiation imaging is here presented. Two different mathematical models have been followed: the simpler ray-optical approach and the more rigorous Fresnel-Kirchoff diffraction theory. Subsequently, the conditions upon which th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2126207

    authors: Peterzol A,Olivo A,Rigon L,Pani S,Dreossi D

    更新日期:2005-12-01 00:00:00

  • A novel computer-aided lung nodule detection system for CT images.

    abstract:PURPOSE:The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. METHODS:The CAD system was trained and t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3633941

    authors: Tan M,Deklerck R,Jansen B,Bister M,Cornelis J

    更新日期:2011-10-01 00:00:00

  • A unified material decomposition framework for quantitative dual- and triple-energy CT imaging.

    abstract:PURPOSE:Many clinical applications depend critically on the accurate differentiation and classification of different types of materials in patient anatomy. This work introduces a unified framework for accurate nonlinear material decomposition and applies it, for the first time, in the concept of triple-energy CT (TECT)...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12933

    authors: Zhao W,Vernekohl D,Han F,Han B,Peng H,Yang Y,Xing L,Min JK

    更新日期:2018-07-01 00:00:00

  • Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

    abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1617550

    authors: Ganguly A,Rudin S,Bednarek DR,Hoffmann KR

    更新日期:2003-11-01 00:00:00

  • Response of tissue-equivalent ionization chamber to 15-MeV neutrons.

    abstract::The calibration (in rad/nC) of an air-filled tissue-equivalent ionization chamber for neutrons of 15-MeV average energy was determined by measuring absolute fluences and calculating the kerma per unit fluence. The neutron calibration determined from the gamma-ray calibration and application of the Bragg-Gray relation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594310

    authors: Barschall HH,Goldberg E

    更新日期:1977-03-01 00:00:00

  • Low-dose dynamic myocardial perfusion CT imaging using a motion adaptive sparsity prior.

    abstract:PURPOSE:Dynamic myocardial perfusion computed tomography (DM-PCT) imaging offers benefits over quantitative assessment of myocardial blood flow (MBF) for diagnosis and risk stratification of coronary artery disease. However, one major drawback of DM-PCT imaging is that a high radiation level is imparted by repeated sca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12285

    authors: Bian Z,Zeng D,Zhang Z,Gong C,Tian X,Yan G,Huang J,Guo H,Chen B,Zhang J,Feng Q,Chen W,Ma J

    更新日期:2017-09-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • An optimized ultrasound detector for photoacoustic breast tomography.

    abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792462

    authors: Xia W,Piras D,van Hespen JC,van Veldhoven S,Prins C,van Leeuwen TG,Steenbergen W,Manohar S

    更新日期:2013-03-01 00:00:00

  • Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation.

    abstract:PURPOSE:Intensity modulated proton therapy (IMPT) of head and neck (H&N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908223

    authors: Landry G,Nijhuis R,Dedes G,Handrack J,Thieke C,Janssens G,Orban de Xivry J,Reiner M,Kamp F,Wilkens JJ,Paganelli C,Riboldi M,Baroni G,Ganswindt U,Belka C,Parodi K

    更新日期:2015-03-01 00:00:00

  • A restricted angular scattering model for electron penetration in dense media.

    abstract::A restricted angular scattering model for electron penetration in dense media is presented. In the model, the Fermi-Eyges transport equation is modified through the addition of an extra term which may be interpreted as representing an apparent force opposing the scattering of electrons into wider angles. The introduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596747

    authors: McLellan J,Sandison GA,Papiez L,Huda W

    更新日期:1991-01-01 00:00:00

  • Average glandular dose coefficients for pendant-geometry breast CT using realistic breast phantoms.

    abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12477

    authors: Hernandez AM,Boone JM

    更新日期:2017-10-01 00:00:00

  • Real-time direct diaphragm tracking using kV imaging on a standard linear accelerator.

    abstract:PURPOSE:As the predominant driver of respiratory motion, the diaphragm represents a key surrogate for motion management during the irradiation of thoracic cancers. Existing approaches to diaphragm tracking often produce phase-based estimates, suffer from lateral side failures or are not executable in real-time. In this...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13738

    authors: Hindley N,Keall P,Booth J,Shieh CC

    更新日期:2019-10-01 00:00:00

  • Technical note: a fast laser-based optical-CT scanner for three-dimensional radiation dosimetry.

    abstract:PURPOSE:To introduce a novel laser-based optical-CT scanner for the readout of three-dimensional (3D) radiation dosimeters. METHODS:The scanner employs a diode laser, a cylindrical lens, a motorized linear rail, a rotation stage, and a charge-coupled device camera. The scanner operates in a translate-rotate fashion an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3538924

    authors: Papadakis AE,Maris TG,Zacharakis G,Papoutsaki V,Varveris C,Ripoll J,Damilakis J

    更新日期:2011-02-01 00:00:00

  • A simple model for examining issues in radiotherapy optimization.

    abstract::Convolution/superposition software has been used to produce a library of photon pencil beam dose matrices. This library of pencil beams is designed to serve as a tool for both education and investigation in the field of radiotherapy optimization. The elegance of this pencil beam model stems from its cylindrical symmet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598615

    authors: Shepard DM,Olivera G,Angelos L,Sauer O,Reckwerdt P,Mackie TR

    更新日期:1999-07-01 00:00:00

  • Directional scatter imaging for the stereoscopic tracking of fiducial markers in a single kV exposure.

    abstract:PURPOSE:To demonstrate, via Monte Carlo simulation, that an image obtained from the patient-generated scattered radiation forced to impinge on the detector from a known direction by means of parallel-focused grids, can be used to complement the information conveyed by the primary image, such that accurate stereoscopic ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12712

    authors: Garnica-Garza HM

    更新日期:2018-02-01 00:00:00

  • A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery.

    abstract::The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598962

    authors: Robar JL,Clark BG

    更新日期:2000-05-01 00:00:00

  • Direct cone-beam cardiac reconstruction algorithm with cardiac banding artifact correction.

    abstract::Multislice helical computed tomography (CT) is a promising noninvasive technique for coronary artery imaging. Various factors can cause inconsistencies in cardiac CT data, which can result in degraded image quality. These inconsistencies may be the result of the patient physiology (e.g., heart rate variations), the na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2163247

    authors: Taguchi K,Chiang BS,Hein IA

    更新日期:2006-02-01 00:00:00

  • The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery.

    abstract::A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing tr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598500

    authors: Murphy MJ

    更新日期:1999-02-01 00:00:00