Potential of in vivo MRI-based nonlinear finite-element analysis for the assessment of trabecular bone post-yield properties.

Abstract:

PURPOSE:Bone strength is the key factor impacting fracture risk. Assessment of bone strength from high-resolution (HR) images have largely relied on linear micro-finite element analysis (μFEA) even though failure always occurs beyond the yield point, which is outside the linear regime. Nonlinear μFEA may therefore be more informative in predicting failure behavior. However, existing nonlinear models applied to trabecular bone (TB) have largely been confined to micro-computed tomography (μCT) and, more recently, HR peripheral quantitative computed tomography (HR-pQCT) images, and typically have ignored evaluation of the post-yield behavior. The primary purpose of this work was threefold: (1) to provide an improved algorithm and program to assess TB yield as well as post-yield properties; (2) to explore the potential benefits of nonlinear μFEA beyond its linear counterpart; and (3) to assess the feasibility and practicality of performing nonlinear analysis on desktop computers on the basis of micro-magnetic resonance (μMR) images obtained in vivo in patients. METHODS:A method for nonlinear μFE modeling of TB yield as well as post-yield behavior has been designed where material nonlinearity is captured by adjusting the tissue modulus iteratively according to the tissue-level effective strain obtained from linear analysis using a computationally optimized algorithm. The software allows for images at in vivo μMRI resolution as input with retention of grayscale information. Associations between axial stiffness estimated from linear analysis and yield as well as post-yield parameters from nonlinear analysis were investigated from in vivo μMR images of the distal tibia (N = 20; ages: 58-84) and radius (N = 20; ages: 50-75). RESULTS:All simulations were completed in 1 h or less for 61 strain levels using a desktop computer (dual quad-core Xeon 3.16 GHz CPUs equipped with 40 GB of RAM). Although yield stress and ultimate stress correlated strongly (R(2) > 0.95, p < 0.001) with axial stiffness, toughness correlated moderately at the distal tibia (R(2) = 0.81, p < 0.001) and only weakly at the distal radius (R(2) = 0.34, p = 0.007). Further, toughness was found to vary by up to 16% for bone of very similar axial stiffness (<2%). CONCLUSIONS:The work demonstrates the practicality of nonlinear μFE simulations at in vivo μMRI resolution, as well as its potential for providing additional information beyond that obtainable from linear analysis. The data suggest that a direct assessment of toughness may provide information not captured by stiffness.

journal_name

Med Phys

journal_title

Medical physics

authors

Zhang N,Magland JF,Rajapakse CS,Bhagat YA,Wehrli FW

doi

10.1118/1.4802085

subject

Has Abstract

pub_date

2013-05-01 00:00:00

pages

052303

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities.

    abstract:PURPOSE:The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. METHODS:Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)-two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a (7)Li-enriched LiF:Mg,Ti-based (MTS-7s)-as well as EBT2 Ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4886760

    authors: Bueno M,Carrasco P,Jornet N,Muñoz-Montplet C,Duch MA

    更新日期:2014-08-01 00:00:00

  • A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

    abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947123

    authors: Giri MG,Cavedon C,Mazzarotto R,Ferdeghini M

    更新日期:2016-05-01 00:00:00

  • The delta envelope: a technique for dose distribution comparison.

    abstract::The gamma index is a tool that compares a dose distribution with a reference distribution by combining dose-difference and distance-to-agreement criteria. It has been widely used for ten years despite its high computational cost. This cost is due to both a search process for each reference point and the necessity to r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3070546

    authors: Blanpain B,Mercier D

    更新日期:2009-03-01 00:00:00

  • Transverse axial film tomography with a therapy simulator.

    abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594662

    authors: Kessaris ND,Harisiadis L

    更新日期:1980-03-01 00:00:00

  • Investigation of three radiation detectors for accurate measurement of absorbed dose in nonstandard fields.

    abstract:PURPOSE:To establish accurate experimental dosimetry techniques for reference dose measurements in nonstandard composite fields. METHODS:A cylindrical PMMA phantom filled with water was constructed, at the center of which reference absorbed dose to water for a head and neck IMRT delivery was measured. Based on the pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3392247

    authors: Chung E,Bouchard H,Seuntjens J

    更新日期:2010-06-01 00:00:00

  • Semiautomated four-dimensional computed tomography segmentation using deformable models.

    abstract::The purpose of this work is to demonstrate a proof of feasibility of the application of a commercial prototype deformable model algorithm to the problem of delineation of anatomic structures on four-dimensional (4D) computed tomography (CT) image data sets. We acquired a 4D CT image data set of a patient's thorax that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1929207

    authors: Ragan D,Starkschall G,McNutt T,Kaus M,Guerrero T,Stevens CW

    更新日期:2005-07-01 00:00:00

  • Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12899

    authors: Netherton T,Li Y,Nitsch P,Shaitelman S,Balter P,Gao S,Klopp A,Muruganandham M,Court L

    更新日期:2018-06-01 00:00:00

  • Image-based 3D modeling study of the influence of vessel density and blood hemoglobin concentration on tumor oxygenation and response to irradiation.

    abstract:PURPOSE:Hypoxia is one of the most important factors influencing clinical outcome after radiotherapy. Improved knowledge of factors affecting the levels and distribution of oxygen within a tumor is needed. The authors constructed a theoretical 3D model based on histological images to analyze the influence of vessel den...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773886

    authors: Lagerlöf JH,Kindblom J,Cortez E,Pietras K,Bernhardt P

    更新日期:2013-02-01 00:00:00

  • Scanned-projection digital mammography.

    abstract::The effectiveness of film-screen mammography is limited by tradeoffs between latitude and contrast, film granularity, and the need to increase dose when antiscatter methods are used. We are currently developing a scanned-projection digital mammography (SPDM) system to overcome these limitations. The system consists of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596147

    authors: Nishikawa RM,Mawdsley GE,Fenster A,Yaffe MJ

    更新日期:1987-09-01 00:00:00

  • Computational modeling of 915 MHz microwave ablation: Comparative assessment of temperature-dependent tissue dielectric models.

    abstract:PURPOSE:The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12359

    authors: Deshazer G,Hagmann M,Merck D,Sebek J,Moore KB,Prakash P

    更新日期:2017-09-01 00:00:00

  • Poster - Thurs Eve-38: CT Imaging in high dose rate brachytherapy for treatment of cervical cancer: Estimation of dose to bowel.

    abstract::Treatment of cervical cancer often involves intracavitary high dose rate (HDR) brachytherapy. Dose delivered to the bladder and rectum are typically estimated using the ICRU reference points. Dose to the sigmoid and small bowel are not estimated, yet these organs typically exhibit significant complication rates. The o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965957

    authors: Lekx-Toniolo KS,Hunter R,Patel M,Voruganti S,Johanson C,Dhamanaskar K,Farrell T

    更新日期:2008-07-01 00:00:00

  • Comparison of two independent exposure measurement techniques for clinical I-125 seeds.

    abstract::This investigation contains the results of exposure measurements on two types of clinical I-125 seeds: a model 6702 no-marker seed, and a model 6711 silver wire seed. Measurements were made locally with a parallel-plate mammography chamber, traceable to the National Bureau of Standards (NBS) calibration. The same seed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595784

    authors: Kubo H

    更新日期:1985-03-01 00:00:00

  • Minimax optimization for handling range and setup uncertainties in proton therapy.

    abstract:PURPOSE:Intensity modulated proton therapy (IMPT) is sensitive to errors, mainly due to high stopping power dependency and steep beam dose gradients. Conventional margins are often insufficient to ensure robustness of treatment plans. In this article, a method is developed that takes the uncertainties into account duri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3556559

    authors: Fredriksson A,Forsgren A,Hårdemark B

    更新日期:2011-03-01 00:00:00

  • Validation of a deformable image registration technique for cone beam CT-based dose verification.

    abstract:PURPOSE:As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903292

    authors: Moteabbed M,Sharp GC,Wang Y,Trofimov A,Efstathiou JA,Lu HM

    更新日期:2015-01-01 00:00:00

  • Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy.

    abstract:PURPOSE:Brachytherapy is a treatment modality which delivers large doses of radiation in a reduced number of visits. Since a small number of large dose-per-fraction is administered in high dose rate brachytherapy, ensuring the right dose is delivered is highly critical. In this work, a scintillation detector is coupled...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13508

    authors: Tho D,Beaulieu L

    更新日期:2019-05-01 00:00:00

  • SU-E-J-142: Gafchromic Film Dosimetry in Fluoroscopy for Dynamic Tumor Tracking Irradiation of the Lung Using XR-SP2 Model - A Phantom Study.

    abstract:PURPOSE:We have recently developed a dynamic tumor tracking irradiation system using Vero4DRT (MHI-Tm2 000). It is needed to create a 4D correlation model between a fiducial marker implanted near a tumor and an external surrogate as a function of time by continuously acquiring both fluoroscopy images and external surro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734978

    authors: Shiinoki T,Sawada A,Ishihara Y,Miyabe Y,Fujimoto T,Nakai T,Matsuo Y,Mizowaki T,Kokubo M,Hiraoka M

    更新日期:2012-06-01 00:00:00

  • SU-E-T-159: Sensitivity of in Line Real Time Scintillating Fiber Detectors for External Beam Treatment Verification and Patient Safety.

    abstract:PURPOSE:We studied the sensitivity of a novel transmission fiber scintillator array designed and built for in line treatment verification. The purpose of this project is to assess the capability of the fiber detector array technology to detect treatment errors in real time without false positives to enhance patient saf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735217

    authors: Izaguirre EW,Price SG,Smajlovic S,Yaddanapudi S,Wooten H,Mutic S

    更新日期:2012-06-01 00:00:00

  • Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint.

    abstract:PURPOSE:Currently, in clinical practice of intensity-modulated proton therapy (IMPT), the influence of the minimum monitor unit (MU) constraint is taken into account through postprocessing after the optimization is completed. This may degrade the plan quality and plan robustness. This study aims to mitigate the impact ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12677

    authors: Shan J,An Y,Bues M,Schild SE,Liu W

    更新日期:2018-01-01 00:00:00

  • Use of proximal operator graph solver for radiation therapy inverse treatment planning.

    abstract:PURPOSE:Most radiation therapy optimization problems can be formulated as an unconstrained problem and solved efficiently by quasi-Newton methods such as the Limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. However, several next generation planning techniques such as total variation regularization- b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12165

    authors: Liu X,Pelizzari C,Belcher AH,Grelewicz Z,Wiersma RD

    更新日期:2017-04-01 00:00:00

  • Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data.

    abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13731

    authors: Niebler S,Schömer E,Tjaden H,Schwanecke U,Schulze R

    更新日期:2019-10-01 00:00:00

  • Use of the fast Hartley transform for three-dimensional dose calculation in radionuclide therapy.

    abstract::Effective radioimmunotherapy may depend on a priori knowledge of the radiation absorbed dose distribution obtained by trace imaging activities administered to a patient before treatment. A new, fast, and effective treatment planning approach is developed to deal with a heterogeneous activity distribution. Calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598422

    authors: Erdi AK,Yorke ED,Loew MH,Erdi YE,Sarfaraz M,Wessels BW

    更新日期:1998-11-01 00:00:00

  • Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments.

    abstract:PURPOSE:To perform a comprehensive and systematic comparison of fixed-beam IMRT and volumetric modulated arc therapy (VMAT) patient-specific QA measurements for a common set of geometries using typical measurement methods. METHODS:Fixed-beam IMRT and VMAT plans were constructed for structure set geometries provided by...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4729738

    authors: Mancuso GM,Fontenot JD,Gibbons JP,Parker BC

    更新日期:2012-07-01 00:00:00

  • Solid-tumor radionuclide therapy dosimetry: new paradigms in view of tumor microenvironment and angiogenesis.

    abstract:PURPOSE:The objective of this study is to evaluate requirements for radionuclide-based solid tumor therapy by assessing the radial dose distribution of beta-particle-emitting and alpha-particle-emitting molecules localized either solely within endothelial cells of tumor vasculature or diffusing from the vasculature thr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3431999

    authors: Zhu X,Palmer MR,Makrigiorgos GM,Kassis AI

    更新日期:2010-06-01 00:00:00

  • Sci-Thurs PM: Delivery-03: Optical imaging of microscopic radiation dose gradients using a digital microscope.

    abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965910

    authors: Keller BM,Peressotti C,Pignol JP

    更新日期:2008-07-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • Dental enamel as an in vivo radiation dosimeter.

    abstract::The determination of the radiation exposure history of the population has become increasingly important in the study of the effects of low-level radiation. The present work was started to try to obtain an in vivo dosimeter that could give an indication of radiation exposure. Dental enamel is the only living tissue whi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595768

    authors: Pass B,Aldrich JE

    更新日期:1985-05-01 00:00:00

  • Resampling: an optimization method for inverse planning in robotic radiosurgery.

    abstract::By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design per...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2357020

    authors: Schweikard A,Schlaefer A,Adler JR Jr

    更新日期:2006-11-01 00:00:00

  • Direct digitization of optical images using a photostimulable phosphor system.

    abstract::The authors describe a method for directly digitizing optical images with a photostimulable phosphor (PSP) system. A PSP plate is initially charged with an exposure to a uniform x-ray field, and is then exposed to an optical image which discharges the plate in relation to the amount of incident light. Two applications...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596917

    authors: Dobbins JT 3rd,Chotas HG,Benveniste H

    更新日期:1992-07-01 00:00:00

  • Poster - Thur Eve - 66: A planning comparison between RapidArc and intensity modulated radiotherapy for head and neck cancer.

    abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740174

    authors: Jiang R,Fleck A,Schaly B,Charland P,Zhan L,Alliet K,Rachakonda R,Osei E

    更新日期:2012-07-01 00:00:00

  • Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera.

    abstract:PURPOSE:Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50-80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antib...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921997

    authors: Miller BW,Frost SH,Frayo SL,Kenoyer AL,Santos E,Jones JC,Green DJ,Hamlin DK,Wilbur DS,Fisher DR,Orozco JJ,Press OW,Pagel JM,Sandmaier BM

    更新日期:2015-07-01 00:00:00