Investigation of three radiation detectors for accurate measurement of absorbed dose in nonstandard fields.

Abstract:

PURPOSE:To establish accurate experimental dosimetry techniques for reference dose measurements in nonstandard composite fields. METHODS:A cylindrical PMMA phantom filled with water was constructed, at the center of which reference absorbed dose to water for a head and neck IMRT delivery was measured. Based on the proposed new formalism for reference dosimetry of nonstandard fields [Alfonso et al., Med. Phys. 35, 5179-5186 (2008)], a candidate plan-class specific reference (pcsr) field for a typical head and neck IMRT delivery was created on the CT images of the phantom. The absorbed dose to water in the pcsr field normalized to that in a reference 10 x 10 cm2 field was measured using three radiation detectors: Gafchromic EBT films, a diamond detector, and a guarded liquid-filled ionization chamber developed in-house (GLIC-03). Pcsr correction factors [formula in text] were determined for five different types of air-filled ionization chambers (Exradin A12, NE-2571, Exradin A1SL, Exradin A14, and PinPoint 31006) in a fully rotated delivery and in a delivery with the same MLC settings and weights but from a single gantry angle (a collapsed delivery). RESULTS:The combined standard uncertainty in measuring the correction factor [formula in text] using the three dosimetry techniques was 0.3%. For all the air-filled ionization chambers and the pcsr field tested, the correction factor was not different from unity by more than +/- 0.8%. For the fully rotated delivery, the correction factors were in a narrow range of 0.9955-0.9986, while in the collapsed delivery, they were in a slightly broader range of 0.9922-1.0048. In the collapsed delivery, the Farmer-type chambers (Exradin A12 and NE2571) had very similar correction factors (0.9922 and 0.9931, respectively), whereas the correction factors for the smaller chambers showed more distinct chamber-type dependence. CONCLUSIONS:The authors have established three experimental dosimetry techniques that allow reference measurements of nonstandard field correction factors [formula in text] for air-filled ionization chambers at the 0.3% 1sigma uncertainty level. These techniques can be used to determine criteria for the selection of plan-class specific reference fields and ultimately improve clinical reference dosimetry of nonstandard fields.

journal_name

Med Phys

journal_title

Medical physics

authors

Chung E,Bouchard H,Seuntjens J

doi

10.1118/1.3392247

subject

Has Abstract

pub_date

2010-06-01 00:00:00

pages

2404-13

issue

6

eissn

0094-2405

issn

2473-4209

journal_volume

37

pub_type

杂志文章
  • Use of 48Ca as a stable isotope tracer analyzed by proton activation.

    abstract::The use of the stable isotope 48Ca as a tracer in biological systems has been studied. Determination of 48Ca concentrations in samples was accomplished by proton activation via the (p,n) reaction with subsequent measurement of gamma-ray spectra from 44-h 48Sc and 4-h 44Sc. With protons of about 5.5 MeV and a Ge(Li) ga...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594303

    authors: Edwards FM,Kraushaar JJ,Ristinen RA,Rudolph H

    更新日期:1977-01-01 00:00:00

  • Measurements of magnetism-related forces and torque moments affecting medical instruments, implants, and foreign objects during magnetic resonance imaging at all degrees of freedom.

    abstract::We designed a novel force/torque moment transducer with six degrees of freedom. This new sensor is used for measuring the forces and torque moments exerted by static magnetic resonance imaging (MRI) fields on various medical implants, instruments, and ballistic shell fragments. To determine the location of strongest e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597853

    authors: Planert J,Modler H,Vosshenrich R

    更新日期:1996-06-01 00:00:00

  • Toward a statistically relevant calibration end point for prostate seed implants.

    abstract::Interstitial brachytherapy for carcinoma of the prostate is achieved through the use of a configuration of radioactive seeds placed in a manner that delivers a customized, reasonably uniform dose to the target volume. Accurate dose delivery depends on both precise seed placement and reliable seed strength in the impla...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598877

    authors: Rosenzweig DP,Schell MC,Yu Y

    更新日期:2000-01-01 00:00:00

  • Direct data link between a CT scanner and a radiation treatment planning system.

    abstract::A direct data link between a CT scanner and a radiation treatment planning system has been developed. The link transmits the data serially over a coaxial cable using the pseudo-paper-tape punch and reader (serial PIO) interfaces. The data transmission rate with error-check is approximately 25,000 8-bit bytes/s. This t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594536

    authors: Abel RN,Buhler LA,Chu WT,Slater JM,Neilsen IR,Zimmerman DC

    更新日期:1979-09-01 00:00:00

  • Computerized radiographic texture measures for characterizing bone strength: a simulated clinical setup using femoral neck specimens.

    abstract::We are investigating computerized methods to ultimately characterize bone trabecular pattern from clinical skeletal radiographs. In this paper, we present a "phantom" for potential use in the development and evaluation of computerized methods for characterizing radiographic trabecular patterns and ultimately bone stre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598743

    authors: Chinander MR,Giger ML,Martell JM,Jiang C,Favus MJ

    更新日期:1999-11-01 00:00:00

  • Noninvasive eye localization in ocular proton therapy through optical eye tracking: A proof of concept.

    abstract:PURPOSE:Over the last four decades, Ocular Proton Therapy has been successfully used to treat patients affected by intraocular lesions. For this, treatment geometry verification is routinely performed using radiographic images to align a configuration of fiducial radiopaque markers implanted on the sclera outer surface...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12841

    authors: Via R,Hennings F,Fattori G,Fassi A,Pica A,Lomax A,Weber DC,Baroni G,Hrbacek J

    更新日期:2018-05-01 00:00:00

  • Technical note: An algorithm to calculate the tissue phantom ratio from depth dose in radiosurgery.

    abstract:PURPOSE:To propose a method to calculate the tissue phantom ratio (TPR) using the depth dose and to compare the proposed method with two other methods. METHODS:An analytical dose model from Bjärngard was used to describe the depth dose and the TPR. The parameters of the model were derived from depth dose measurements,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3570575

    authors: Ramos Garcia LI,Almansa JF

    更新日期:2011-05-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model.

    abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598111

    authors: Liu HH,Mackie TR,McCullough EC

    更新日期:1997-12-01 00:00:00

  • SU-E-I-99: An Ultra-High Resolution Small Field-Of-View Solid State X-Ray Imaging Detector Based on an Electron Multiplying CCD.

    abstract:PURPOSE:To demonstrate the ultra-high resolution capability of a small field-of-view (FOV) solid state x-ray imaging detector based on an EMCCD sensor. METHODS:A micro-solid state x-ray image intensifier (micro-SSXII) was developed to serve as an ultra-high resolution region-of-interest (ROI) imaging detector. It is b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734816

    authors: Singh V,Loughran B,Jain A,Sharma P,Bednarek D,Rudin S

    更新日期:2012-06-01 00:00:00

  • The water-equivalence of phantom materials for 90Sr-90Y beta particles.

    abstract::Intravascular brachytherapy requires that the dose be specified within millimeters of the source. High dose gradients near brachytherapy sources require that the source-detector distance be accurately known for dosimetry purposes. Solid phantoms can be designed to accommodate these stringent requirements. This study r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1376176

    authors: Buckley LA,Thomadsen BR,DeWerd LA

    更新日期:2001-06-01 00:00:00

  • Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer.

    abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4748332

    authors: Donovan EM,James H,Bonora M,Yarnold JR,Evans PM

    更新日期:2012-10-01 00:00:00

  • Treatment planning system and beam data validation for the ZAP-X: a novel self-shielded stereotactic radiosurgery system.

    abstract:PURPOSE:To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS:A comprehensive set of TPS commissioning and validation tests were developed using published guidelines. Nondosimetric validatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14740

    authors: Srivastava SP,Jani SS,Pinnaduwage DS,Yan X,Rogers L,Barranco FD,Barani IJ,Sorensen S

    更新日期:2021-01-28 00:00:00

  • Radiative transport in the delta-P1 approximation for semi-infinite turbid media.

    abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2828184

    authors: Seo I,Hayakawa CK,Venugopalan V

    更新日期:2008-02-01 00:00:00

  • Continuous time-dependence in computed tomography.

    abstract::Computed tomography is sensitive to changes in the imaged distribution during acquisition of the projection data. Previous investigations have emphasized discrete or discontinuous changes in the imaged object. Recent advances have motivated our investigation of object time-dependence characterized by a continuous func...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594458

    authors: Holden JE,Ip WR

    更新日期:1978-11-01 00:00:00

  • Implementation of a quality assurance program for computerized treatment planning systems.

    abstract::In the present investigation, the necessary tests for implementing a quality assurance program for a commercial treatment planning system (TPS), recently installed at Sao Paulo University School of Medicine Clinicas Hospital-Brazil, was established and performed in accordance with the new IAEA publication TRS 430, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2742779

    authors: Camargo PR,Rodrigues LN,Furnari L,Rubo RA

    更新日期:2007-07-01 00:00:00

  • Technical Note: Characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM.

    abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930245

    authors: Price RG,Kadbi M,Kim J,Balter J,Chetty IJ,Glide-Hurst CK

    更新日期:2015-10-01 00:00:00

  • Technical Note: Noninvasive mid-IR fiber-optic evanescent wave spectroscopy (FEWS) for early detection of skin cancers.

    abstract:PURPOSE:Melanoma is the most lethal of the three primary skin cancers, including also basal cell carcinoma (BCC) and squamous cell carcinoma (SCC), which are less lethal. The accepted diagnosis process involves manually observing a suspicious lesion through a Dermascope (i.e., a magnifying glass), followed by a biopsy....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14471

    authors: Basov S,Dankner Y,Weinstein M,Katzir A,Platkov M

    更新日期:2020-11-01 00:00:00

  • Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation.

    abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812429

    authors: Driscoll B,Keller H,Jaffray D,Coolens C

    更新日期:2013-08-01 00:00:00

  • X-ray phase contrast imaging of the breast: analysis of tissue simulating materials.

    abstract:PURPOSE:Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794503

    authors: Vedantham S,Karellas A

    更新日期:2013-04-01 00:00:00

  • WE-G-217A-08: Routine ACR SNR Measurement Failed to Detect 32-Channel Head Coil Receiver Malfunction.

    abstract:PURPOSE:To study if malfunction of a receiver can be detected robustly using the simple ACR SNR measurement approach on a 32-channel head coil. METHODS:Standard ACR T1W images (11slice) were acquired with a commercial 32 channel head coil on a 3T Philips Achieva MR scanner following the ACR recommended setup. Raw data...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736227

    authors: Peng Q

    更新日期:2012-06-01 00:00:00

  • Benchmarking analytical calculations of proton doses in heterogeneous matter.

    abstract::A proton dose computational algorithm, performing an analytical superposition of infinitely narrow proton beamlets (ASPB) is introduced. The algorithm uses the standard pencil beam technique of laterally distributing the central axis broad beam doses according to the Moliere scattering theory extended to slablike vary...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2064887

    authors: Ciangaru G,Polf JC,Bues M,Smith AR

    更新日期:2005-12-01 00:00:00

  • Urinary bladder cancer staging in CT urography using machine learning.

    abstract:PURPOSE:To evaluate the feasibility of using an objective computer-aided system to assess bladder cancer stage in CT Urography (CTU). MATERIALS AND METHODS:A dataset consisting of 84 bladder cancer lesions from 76 CTU cases was used to develop the computerized system for bladder cancer staging based on machine learnin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12510

    authors: Garapati SS,Hadjiiski L,Cha KH,Chan HP,Caoili EM,Cohan RH,Weizer A,Alva A,Paramagul C,Wei J,Zhou C

    更新日期:2017-11-01 00:00:00

  • Technical Note: Performance comparison of ultra-high-resolution scan modes of two clinical computed tomography systems.

    abstract:PURPOSE:Two ultra-high-resolution (UHR) computed tomography (CT) scanners are clinically available. One is achieved by a CT system with a 0.25 mm × 160 row detector (Detector-UHR), whereas the other is with a 0.6 mm × 32 row detector with in-plane comb filtering in a dual source CT (Comb-UHR). We compared radiation dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13949

    authors: Kawashima H,Ichikawa K,Takata T,Nagata H,Hoshika M,Akagi N

    更新日期:2020-02-01 00:00:00

  • Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate 192 Ir brachytherapy sources.

    abstract:PURPOSE:Experimental dosimetry of high-dose-rate (HDR) 192 Ir brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high se...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12694

    authors: Kaveckyte V,Malusek A,Benmakhlouf H,Alm Carlsson G,Carlsson Tedgren Å

    更新日期:2018-01-01 00:00:00

  • SU-E-J-63: Feasibility Study of Proton Digital Tomosynthesis in Proton Beam Therapy.

    abstract:PURPOSE:We investigated the feasibility of proton tomosynthesis as daily positioning of patients and compared the results with photon tomosynthesis as an alternative to conventional portal imaging or on-board cone-beam computed tomography. METHODS:Dedicated photon-like proton beam using the passively scattered proton ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734898

    authors: Min B,Kwak J,Lee J,Cho S,Park S,Yoo S,Chung K,Cho S,Lim Y,Shin D,Lee S,Kim J

    更新日期:2012-06-01 00:00:00

  • Dosimetric impact of geometric errors due to respiratory motion prediction on dynamic multileaf collimator-based four-dimensional radiation delivery.

    abstract::The synchronization of dynamic multileaf collimator (DMLC) response with respiratory motion is critical to ensure the accuracy of DMLC-based four dimensional (4D) radiation delivery. In practice, however, a finite time delay (response time) between the acquisition of tumor position and multileaf collimator response ne...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1915017

    authors: Vedam S,Docef A,Fix M,Murphy M,Keall P

    更新日期:2005-06-01 00:00:00

  • Real-time distortionless high-factor compression scheme.

    abstract::Nowadays, digital subtraction angiography systems must be able to sustain real-time acquisition (30 frames per second) of 512 x 512 x 8 bit images and store several sequences of such images on low cost and general-purpose mass memories. Concretely, that means a 7.8 Mbytes per second rate and about 780 Mbytes disk spac...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596309

    authors: Liénard J

    更新日期:1989-11-01 00:00:00

  • Calculation of monitor units for a linear accelerator with asymmetric jaws.

    abstract::A simple approach was developed that calculates the output factors and tissue maximum ratio of an asymmetric field at any point within the open field, and specifically both at the central axis (when the jaws do not shadow it) and at the effective center of the open field, using the existing tables for symmetric fields...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597524

    authors: Rosenberg I,Chu JC,Saxena V

    更新日期:1995-01-01 00:00:00

  • Changes realized from extended bit-depth and metal artifact reduction in CT.

    abstract:PURPOSE:High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosim...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4805102

    authors: Glide-Hurst C,Chen D,Zhong H,Chetty IJ

    更新日期:2013-06-01 00:00:00