Abstract:
:This paper investigates the effect of the waterproofing sleeve on the calibration of kilovoltage photon beams (50-300 kV). The sleeve effect correction factor, ps has been calculated using the Monte Carlo method as the ratios of the air kerma in an air cavity of a cylindrical chamber without the waterproofing sleeve to that with a sleeve. Three sleeve materials have been studied, PMMA, nylon and polystyrene. The calculations were carried out using the EGS4 (Electron Gamma Shower version 4) code system with the application of a correlated-sampling variance-reduction technique. The results show that the sleeve correction factor for 1-mm thick nylon and polystyrene sleeves, ps varies from 0.992 to 1.000 and from 0.981 to 1.000, respectively, for the same beam quality range. The ps factor varies with sleeve thickness, beam quality and phantom depth. No significant dependence of the ps factor on field size and source-surface distance has been found. Measurements for PMMA, nylon and polystyrene sleeves of various thicknesses have also been carried out and show excellent agreement with Monte Carlo calculations.
journal_name
Med Physjournal_title
Medical physicsauthors
Ma CM,Seuntjens JPdoi
10.1118/1.598039subject
Has Abstractpub_date
1997-09-01 00:00:00pages
1507-13issue
9eissn
0094-2405issn
2473-4209journal_volume
24pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which ...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.12299
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:The combination of nonhuman primates (NHPs) with the state-of-the-art molecular imaging technologies allows for within-subject longitudinal research aiming at gaining new insights into human normal and disease conditions and provides an ideal foundation for future translational studies of new diagnostic tools, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14333
更新日期:2020-09-01 00:00:00
abstract:PURPOSE:TransitQA is an innovative method for Tomotherapy transit dosimetry using the on-board detector (OBD). Our previously published model for Tomotherapy treatment plan verification (AirQA) has been enhanced to take into account patient and couch transmission. AirQA estimates the OBD signal during irradiation with ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12672
更新日期:2018-01-01 00:00:00
abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599033
更新日期:2000-07-01 00:00:00
abstract:PURPOSE:The ability to monitor intrafractional tumor motion is essential for radiation therapy of thoracic and abdominal tumors. This study aims to develop a method to track lung tumor motion using intrafractional continuous ultrasound (US) and periodic cone-beam projection images (CBPI). METHODS:Time-sequenced b-mode...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13104
更新日期:2018-10-01 00:00:00
abstract::It is shown that predictions can be made of scatter-to-primary ratios for a variety of mammographic configurations. The different configurations can be produced by changes in source-detector distance; source-phantom distance; air gap; photon energy; phantom composition, thickness, and cross-sectional area. A detailed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595807
更新日期:1986-11-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD). METHODS:Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and exp...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4813906
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a succe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3366252
更新日期:2010-04-01 00:00:00
abstract::A new variety of tissue-mimicking materials for use in 1H nuclear magnetic resonance (NMR) phantoms has been developed and extensively tested, principally at 10 MHz and at room temperature. The materials can be formed with a broad range of T1's and T2's representative of soft tissues. They are mixtures of various perc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596219
更新日期:1988-07-01 00:00:00
abstract::A new approach to the calculation of the x-ray spectrum emerging from an x-ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate brems...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2734726
更新日期:2007-06-01 00:00:00
abstract::We adapted a small sodium iodide scintillation detector for rapid, in vivo localization of a lost brachytherapy seed. Using the detector, we were able to locate and remove an Ir-192 seed that was not visible to the unaided eye. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595528
更新日期:1984-07-01 00:00:00
abstract:INTRODUCTION:Ultrasound (US) guidance of the prostate has long been conducted using a transabdominal (TA) approach. More recently, a transperineal (TP) approach has been made available for image guidance. Our aim was to determine if both methods produced similar alignments within the same patients. MATERIALS AND METHO...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14522
更新日期:2020-12-01 00:00:00
abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597412
更新日期:1994-10-01 00:00:00
abstract::A simple method to measure the line spread function of computed tomographic scanners has been developed. The line spread function of the EMI-Scanner was measured and the MTF of the scanner was calculated. The reproducibility of the method indicated this technique could be utilized to compare the spatial resolution of ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594283
更新日期:1976-07-01 00:00:00
abstract::Because of the high energy of the treatment beam, contrast of portal verification films is very poor. A simple contrast enhancement technique is described which we have labeled selective histogram equalization (SHE), to improve visualization of double-exposure portal images and this facilitate the beam verification pr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597085
更新日期:1993-01-01 00:00:00
abstract::Postoperative beta-irradiation after pterygium excision has been considered a valuable therapeutic procedure to reduce the recurrence rate. Recently, it was reported that beta-irradiation also substantially reduced the risk of surgical failure after glaucoma surgery. Pure beta-irradiation using a 90Sr/Y applicator has...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2896076
更新日期:2008-05-01 00:00:00
abstract::Using stable materials capable of mimicking any soft tissues of the human body--quantitatively with respect to speed of sound, density, and attenuation coefficient and semiquantitatively with respect to scatter--we have constructed a torso section phantom containing simulated bowel gas, kidney, kidney fat pad, liver, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594657
更新日期:1980-01-01 00:00:00
abstract::A scintillation dosemeter is calibrated for 90Sr/90Y beta rays from an ophthalmic applicator, using an extrapolation ionization chamber as a reference instrument. The calibration factor for the scintillation dosemeter agrees with that given by the manufacturer of the dosemeter within ca. 2%. The estimated overall unce...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1709490
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:Automated segmentation of brain structures (objects) in MR three-dimensional (3D) images for quantitative analysis has been a challenge and probabilistic atlases (PAs) are among the most well-succeeded approaches. However, the existing models do not adapt to possible object anomalies due to the presence of a di...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13771
更新日期:2019-11-01 00:00:00
abstract::Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1469627
更新日期:2002-05-01 00:00:00
abstract::Surgical guidance with fluorescence has been demonstrated in individual clinical trials for decades, but the scientific and commercial conditions exist today for a dramatic increase in clinical value. In the past decade, increased use of indocyanine green based visualization of vascular flow, biliary function, and tis...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4951732
更新日期:2016-06-01 00:00:00
abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2776255
更新日期:2007-10-01 00:00:00
abstract:PURPOSE:To investigate the sensitivity of the plan-class specific correction factor to dose distributions in composite nonstandard field dosimetry. METHODS:A cylindrical water-filled PMMA phantom was constructed at the center of which reference absorbed dose could be measured. Ten different TomoTherapy(®)-based IMRT f...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3669487
更新日期:2012-01-01 00:00:00
abstract:PURPOSE:Color images are visualized on medical monitors that are adjusted by a grayscale standard display function (GSDF) or γ2.2. Although the GSDF is visually displayed as a linear graded grayscale, it does not specify how color medical images should be presented. On the other hand, the usual gamma setting for color ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13532
更新日期:2019-06-01 00:00:00
abstract:PURPOSE:The advent of three-dimensional breast imaging systems such as digital breast tomosynthesis (DBT) has great promise for improving the detection and diagnosis of breast cancer. With these new technologies comes an essential need for testing methods to assess the resultant image quality. Although randomized clini...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13629
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12359
更新日期:2017-09-01 00:00:00
abstract::Imaging parameters associated with a clinical magnetic resonance imaging (MRI) system, evaluated with the use of simple and inexpensive phantoms, are described in evaluation of a clinical MRI system. Images, obtained with a Diasonics 0.35-T MRI system using an elliptical whole-body radio frequency coil, are presented ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595894
更新日期:1986-07-01 00:00:00
abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4921617
更新日期:2015-07-01 00:00:00
abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735574
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Fusion of intraprocedure ultrasound and preprocedure CT data is proposed for guidance in percutaneous spinal injections, a common procedure for pain management. CT scan of the lumbar spine is usually collected in a supine position, whereas spinal injections are performed in prone or sitting positions. This lead...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4711753
更新日期:2012-06-01 00:00:00