Poster - Thur Eve - 64: Evaluation of SmartArc and RapidArc for lung SBRT treatment planning and delivery.

Abstract:

OBJECTIVES:To evaluate the performance of RapidArc® (Eclipse 10.0.28) and SmartArc® (Pinnacle 9.0) radiotherapy plans for lung stereotactic body radiation therapy (SBRT) in terms of dosimetric plan quality, delivery efficiency, inhomogeneity corrections and accuracy of dose delivery using a custom-built heterogeneity insert for ArcCHECK™ (Sun Nuclear Corp., FL, USA). METHODS:SmartArc® and RapidArc® plans were generated for 10 patients. The quality of the plans was evaluated in terms of conformity indices (R100 and R50 ) and the dose to the organs at risk. The efficiency was evaluated in terms of the monitor units (MUs) required for a given prescription dose. For dose verification, we designed and manufactured a heterogeneity insert for ArcCHECK™ with densities that simulate soft tissue, lung, bone, and air and having multiple locations for point dose measurements. Accuracy of dose delivery was assessed using gamma analysis. RESULTS:The overall plan quality was similar when comparing SmartArc® with RapidArc®. However, RapidArc® plans required significantly more MUs-up to 72%™compared with SmartArc® plans (p<0.001). ArcCHECK™ measurements in the presence of inhomogeneities showed better agreement for SmartArc® plans. CONCLUSION:Plan quality for SmartArc® and RapidArc® was comparable. However, SmartArc® plans were more efficient, requiring significantly fewer monitor units, and were delivered more accurately in a non-homogeneous phantom. With the custom-built heterogeneity insert, ArcCHECK™ can be used efficiently to verify inhomogeneity corrections and dose delivery accuracy for lung SBRT plans.

journal_name

Med Phys

journal_title

Medical physics

authors

Fakir H,Hoover D,Chen JZ

doi

10.1118/1.4740172

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

4637

issue

7Part3

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Technical Note: Radiotherapy dose characterization of gel dosimetry using shear wave elasticity imaging.

    abstract:PURPOSE:Radiotherapy is an effective treatment for many types of cancer in clinical settings. Gel dosimetry has the potential to record three-dimensional (3D) dose distribution compared to a conventional ion chamber. As the elasticity of the gel is altered after irradiation due to gel polymerization, we aim to measure ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14020

    authors: Xie WH,Su CT,Kao YJ,Chang TH,Chang YJ,Yao CH,Hsieh BY

    更新日期:2020-03-01 00:00:00

  • Dose optimization in pediatric cardiac x-ray imaging.

    abstract:PURPOSE:The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3488911

    authors: Gislason AJ,Davies AG,Cowen AR

    更新日期:2010-10-01 00:00:00

  • A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

    abstract::To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2956713

    authors: Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

    更新日期:2008-08-01 00:00:00

  • Dual-storage phosphor proton therapy dosimetry: simultaneous quantification of dose and linear energy transfer.

    abstract:PURPOSE:To investigate the feasibility of using the high Zeff storage phosphor material BaFBrI:Eu2+ in conjunction with the low Zeff storage phosphor material KCl:Eu2+ for simultaneous proton dose and linear energy transfer (LET) measurements by 1) measuring the fundamental optical and dosimetric properties of BaFBrI:E...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14748

    authors: Setianegara J,Mazur TR,Yang D,Li HH

    更新日期:2021-02-01 00:00:00

  • Inspection of visible components in urine based on deep learning.

    abstract:PURPOSE:Urinary particles are particularly important parameters in clinical urinalysis, especially for the diagnosis of nephropathy. Therefore, it is highly important to precisely detect urinary particles in the clinical setting. However, artificial microscopy is subjective and time consuming, and various previous dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14118

    authors: Li Q,Yu Z,Qi T,Zheng L,Qi S,He Z,Li S,Guan H

    更新日期:2020-07-01 00:00:00

  • MO-F-BRA-02: Evaluation of 4D CT to 4D Cone-Beam CT Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy.

    abstract:PURPOSE:To evaluate two deformable image registration (DIR) algorithms for the purpose of contour mapping to support image guided adaptive radiotherapy (IGART) with 4D cone beam CT (4DCBCT). METHODS:Eleven locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan- beam CT (4DFBCT) and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735821

    authors: Balik S,Hugo G,Weiss E,Jan N,Roman N,Sleeman W,Fatyga M,Christensen G,Murphy M,Lu J,Keall P,Williamson J

    更新日期:2012-06-01 00:00:00

  • Development of optical process for accessing three-dimensional patient topology.

    abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594447

    authors: Lerch IA,Barish RJ,Stern H

    更新日期:1978-11-01 00:00:00

  • A new pulse sequence for determining T1 and T2 simultaneously.

    abstract::Determination of the relaxation times T1 and T2 which are important for tissue characterization generally requires the use of different pulse sequences in magnetic resonance imaging. In this study, a new pulse sequence which facilitates simultaneous determination of the T1 and T2 times is presented. Determination take...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595867

    authors: Graumann R,Fischer H,Oppelt A

    更新日期:1986-09-01 00:00:00

  • Comparison of p-type commercial electron diodes for in vivo dosimetry.

    abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1630492

    authors: Marre D,Marinello G

    更新日期:2004-01-01 00:00:00

  • Radiofrequency penetration and absorption in the human body: limitations to high-field whole-body nuclear magnetic resonance imaging.

    abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595995

    authors: Röschmann P

    更新日期:1987-11-01 00:00:00

  • Electron disequilibrium in high-energy x-ray beams.

    abstract::The ratio between scatter dose and scatter kerma for points on the central axis of 15-MV x-ray beams has been examined by Monte Carlo calculations. This ratio, beta'S, behaves differently from that between the primary dose and kerma, beta'p. Both the primary and scatter components of beta' undergo an initial rapid bui...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597749

    authors: Hannallah D,Zhu TC,Bjärngard BE

    更新日期:1996-11-01 00:00:00

  • A neural network approach for fast, automated quantification of DIR performance.

    abstract:PURPOSE:A critical step in adaptive radiotherapy (ART) workflow is deformably registering the simulation CT with the daily or weekly volumetric imaging. Quantifying the deformable image registration accuracy under these circumstances is a complex task due to the lack of known ground-truth landmark correspondences betwe...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12321

    authors: Neylon J,Min Y,Low DA,Santhanam A

    更新日期:2017-08-01 00:00:00

  • Dose buildup for obliquely incident photon beams.

    abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596055

    authors: Gerbi BJ,Meigooni AS,Khan FM

    更新日期:1987-05-01 00:00:00

  • A delivery quality assurance tool based on the actual leaf open times in tomotherapy.

    abstract:PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14348

    authors: Schopfer M,Bochud FO,Bourhis J,Moeckli R

    更新日期:2020-09-01 00:00:00

  • Plan averaging for multicriteria navigation of sliding window IMRT and VMAT.

    abstract:PURPOSE:To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. METHODS:The authors show that by taking an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4859295

    authors: Craft D,Papp D,Unkelbach J

    更新日期:2014-02-01 00:00:00

  • WE-G-213CD-03: A Dual Complementary Verification Method for Dynamic Tumor Tracking on Vero SBRT.

    abstract:PURPOSE:to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. METHODS:A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondenc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736204

    authors: Poels K,Depuydt T,Verellen D,De Ridder M

    更新日期:2012-06-01 00:00:00

  • Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

    abstract::Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008467

    authors: Dmochowski J,Hoffmann KR,Singh V,Xu J,Nazareth DP

    更新日期:2005-09-01 00:00:00

  • SU-E-T-269: The Evaluation of Copper as an Alternative for Cerrobend Electron Shielding.

    abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735336

    authors: Chu A,Feng W,Ahmad M,Chen Z,Nath R

    更新日期:2012-06-01 00:00:00

  • Angular measurement of the cobalt-60 emitted radiation spectrum from a radiosurgery irradiator.

    abstract::The photon energy spectrum emanating from a Leksell Gamma Knife, Model 23004B, was measured between 0.250 and 3.5 MeV with the sources exposed. Measurements were made using a 2x2 inch NaI detector enclosed in a lead-shielded apparatus having a 1/4 inch diameter measurement aperture, which reduced the amount of radiati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1355305

    authors: Drzymala RE,Sohn JW,Guo C,Sobotka LG,Purdy JA

    更新日期:2001-04-01 00:00:00

  • Evaluation of CT-based lean-body SUV.

    abstract:PURPOSE:The authors introduce a novel method for defining standardized uptake values (SUVs) in PET∕CT based on routinely collected CT data. The goal of the study is to reduce, if possible, the variability of SUV in a heterogeneous population. Two well established methods for defining SUV are based on body weight (BW) a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4816656

    authors: Hamill JJ,Sunderland JJ,LeBlanc AK,Kojima CJ,Wall J,Martin EB

    更新日期:2013-09-01 00:00:00

  • X-ray imaging with amorphous selenium: optimal spectra for digital mammography.

    abstract::The optimum x-ray spectra for acquisition of digital mammographic images using an amorphous selenium (a-Se) photoconductor are investigated. The recorded images consist of latent charge distributions on the surface of an a-Se plate, which are then read out using two methods, laser discharge, or flat panel recharge. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597688

    authors: Fahrig R,Rowlands JA,Yaffe MJ

    更新日期:1996-04-01 00:00:00

  • High correlation between radiation dose estimates for 256-slice CT obtained by highly parallelized hybrid Monte Carlo computation and solid-state metal-oxide semiconductor field-effect transistor measurements in physical anthropomorphic phantoms.

    abstract:PURPOSE:Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13780

    authors: Prinsen P,Trattner S,Wiegert J,Gerland EL,Shefer E,Morton T,Thompson CM,Cheng B,Halliburton SS,Einstein AJ

    更新日期:2019-11-01 00:00:00

  • Design and evaluation of an MRI-compatible linear motion stage.

    abstract:PURPOSE:To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS:In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4937780

    authors: Tavallaei MA,Johnson PM,Liu J,Drangova M

    更新日期:2016-01-01 00:00:00

  • Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites.

    abstract:PURPOSE:To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. METHODS:A PET-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4867856

    authors: Thomas CM,Pike LC,Hartill CE,Baker S,Woods E,Convery DJ,Greener AG

    更新日期:2014-04-01 00:00:00

  • Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

    abstract::A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436978

    authors: Liu T,Lizzi FL,Ketterling JA,Silverman RH,Kutcher GJ

    更新日期:2007-03-01 00:00:00

  • A consistent set of neutron kerma coefficients from thermal to 150 MeV for biologically important materials.

    abstract::Neutron cross sections for nonelastic and elastic reactions on a range of elements have been evaluated for incident energies up to 150 MeV. These cross sections agree well with experimental cross section data for charged-particle production as well as neutron and photon production. Therefore they can be used to determ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598601

    authors: Chadwick MB,Barschall HH,Caswell RS,DeLuca PM,Hale GM,Jones DT,MacFarlane RE,Meulders JP,Schuhmacher H,Schrewe UJ,Wambersie A,Young PG

    更新日期:1999-06-01 00:00:00

  • Adaptation of a clustered lumpy background model for task-based image quality assessment in x-ray phase-contrast mammography.

    abstract:PURPOSE:Since the introduction of clinical x-ray phase-contrast mammography (PCM), a technique that exploits refractive-index variations to create edge enhancement at tissue boundaries, a number of optimization studies employing physical image-quality metrics have been performed. Ideally, task-based assessment of PCM w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3676183

    authors: Zysk AM,Brankov JG,Wernick MN,Anastasio MA

    更新日期:2012-02-01 00:00:00

  • Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans.

    abstract::Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in the early detection of lung cancer in radiographs and computed tomography (CT) images. In order to improve sensitivity for nodule detection, many researchers have employed a filter as a preprocessing step for enhancement of nodules. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1581411

    authors: Li Q,Sone S,Doi K

    更新日期:2003-08-01 00:00:00

  • Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning.

    abstract::The purpose of this study is to perform a clinical evaluation of the first commercial (MDS Nordion, now Nucletron) treatment planning system for electron beams incorporating Monte Carlo dose calculation module. This software implements Kawrakow's VMC++ voxel-based Monte Carlo calculation algorithm. The accuracy of the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1633105

    authors: Cygler JE,Daskalov GM,Chan GH,Ding GX

    更新日期:2004-01-01 00:00:00

  • Evaluation of video gray-scale display.

    abstract::Setting up and maintaining video display monitors properly will help to reduce display variation and improve overall presentation of the radiological image. Display monitor gray-scale characteristics were examined using the SMPTE test pattern. This test pattern may be used as a standard for adjusting brightness and co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596846

    authors: Nawfel RD,Chan KH,Wagenaar DJ,Judy PF

    更新日期:1992-05-01 00:00:00