A novel PET tumor delineation method based on adaptive region-growing and dual-front active contours.

Abstract:

:To more accurately and precisely delineate a tumor in a 3D PET image, we proposed a novel, semi-automatic, two-stage method by utilizing an adaptive region-growing algorithm and a dual-front active contour model. First, a rough region of interest (ROI) is manually drawn by a radiation oncologist that encloses a tumor. The voxel having the highest intensity in the ROI is chosen as a seed point. An adaptive region growing algorithm successively appends to the seed point all neighboring voxels whose intensities > = T of the mean of the current region. When T varies from 100% to 0%, a sharp volume increase, indicating the transition from the tumor to the background, always occurs at a certain T value. A preliminary tumor boundary is determined just before the sharp volume increase, which is found to be slightly outside of the known tumor in all tested phantoms. A novel dual-front active contour model utilizing region-based information is then applied to refine the preliminary boundary automatically. We tested the two-stage method on six spheres (0.5-20 ml) in a cylindrical container under different source to background ratios. Comparisons between the two-stage method and an iterative threshold method demonstrate its higher detection accuracy for small tumors (less than 6 ml). One patient study was tested and evaluated by two experienced radiation oncologists. The study illustrated that this two-stage method has several advantages. First, it does not require any threshold-volume curves, which are different and must be calibrated for each scanner and image reconstruction method. Second, it does not use any iso-threshold lines as contours. Third, the final result is reproducible and is independent of the manual rough ROIs. Fourth, this method is an adaptive algorithm that can process different images automatically.

journal_name

Med Phys

journal_title

Medical physics

authors

Li H,Thorstad WL,Biehl KJ,Laforest R,Su Y,Shoghi KI,Donnelly ED,Low DA,Lu W

doi

10.1118/1.2956713

subject

Has Abstract

pub_date

2008-08-01 00:00:00

pages

3711-21

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

35

pub_type

杂志文章
  • SU-E-T-162: Rapid Assessment of Cyberknife IRIS Variable Collimator Performance Using a Commercial Diode Array.

    abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735220

    authors: Gibbs G,White G,Bulz G

    更新日期:2012-06-01 00:00:00

  • Statistical variability and confidence intervals for planar dose QA pass rates.

    abstract:PURPOSE:The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3651695

    authors: Bailey DW,Nelms BE,Attwood K,Kumaraswamy L,Podgorsak MB

    更新日期:2011-11-01 00:00:00

  • A novel curvilinear approach for prostate seed implantation.

    abstract:PURPOSE:A new technique called "curvilinear approach" for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. METHODS:Twenty LDR prostate brachytherapy cases planned intraopera...

    journal_title:Medical physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1118/1.3694110

    authors: Podder TK,Dicker AP,Hutapea P,Darvish K,Yu Y

    更新日期:2012-04-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • On the speckle-free nature of photoacoustic tomography.

    abstract:PURPOSE:A long-standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. METHODS:In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validate...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3187231

    authors: Guo Z,Li L,Wang LV

    更新日期:2009-09-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • Detecting electron beam energy shifts with a commercially available energy monitor.

    abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.599033

    authors: Evans MD,Moftah BA,Olivares M,Podgorsak EB

    更新日期:2000-07-01 00:00:00

  • Task Group 284 Report: Magnetic Resonance Imaging Simulation in Radiotherapy: Considerations for Clinical Implementation, Optimization, and Quality Assurance.

    abstract::The use of dedicated magnetic resonance simulation (MR-SIM) platforms in Radiation Oncology has expanded rapidly, introducing new equipment and functionality with the overall goal of improving the accuracy of radiation treatment planning. However, this emerging technology presents a new set of challenges that need to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14695

    authors: Glide-Hurst CK,Paulson ES,McGee K,Tyagi N,Hu Y,Balter J,Bayouth J

    更新日期:2021-01-01 00:00:00

  • Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming.

    abstract:PURPOSE:Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881096

    authors: Maduskar P,Hogeweg L,de Jong PA,Peters-Bax L,Dawson R,Ayles H,Sánchez CI,van Ginneken B

    更新日期:2014-07-01 00:00:00

  • Comparative performance of multiview stereoscopic and mammographic display modalities for breast lesion detection.

    abstract:PURPOSE:Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3562901

    authors: Webb LJ,Samei E,Lo JY,Baker JA,Ghate SV,Kim C,Soo MS,Walsh R

    更新日期:2011-04-01 00:00:00

  • Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy.

    abstract:PURPOSE:In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4934832

    authors: Poulin E,Gardi L,Barker K,Montreuil J,Fenster A,Beaulieu L

    更新日期:2015-12-01 00:00:00

  • A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.

    abstract::Topographic treatment is a radiation therapy delivery technique for fixed-gantry (nonrotational) treatments on a helical tomotherapy system. The intensity-modulated fields are created by moving the treatment couch relative to a fan-beam positioned at fixed gantry angles. The delivered dose distribution is controlled b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2216876

    authors: Desai D,Ramsey CR,Breinig M,Mahan SL

    更新日期:2006-08-01 00:00:00

  • Sci-Thurs PM: Delivery-03: Optical imaging of microscopic radiation dose gradients using a digital microscope.

    abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965910

    authors: Keller BM,Peressotti C,Pignol JP

    更新日期:2008-07-01 00:00:00

  • Dose enhancement in radiotherapy of small lung tumors using inline magnetic fields: A Monte Carlo based planning study.

    abstract:PURPOSE:To report on significant dose enhancement effects caused by magnetic fields aligned parallel to 6 MV photon beam radiotherapy of small lung tumors. Findings are applicable to future inline MRI-guided radiotherapy systems. METHODS:A total of eight clinical lung tumor cases were recalculated using Monte Carlo me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938580

    authors: Oborn BM,Ge Y,Hardcastle N,Metcalfe PE,Keall PJ

    更新日期:2016-01-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • Characterization of difference of Gaussian filters in the detection of mammographic regions.

    abstract::In this article, we present a characterization of the effect of difference of Gaussians (DoG) filters in the detection of mammographic regions. DoG filters have been used previously in mammographic mass computer-aided detection (CAD) systems. As DoG filters are constructed from the subtraction of two bivariate Gaussia...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2358326

    authors: Catarious DM Jr,Baydush AH,Floyd CE Jr

    更新日期:2006-11-01 00:00:00

  • Respiratory phase alignment improves blood-flow quantification in Rb82 PET myocardial perfusion imaging.

    abstract:PURPOSE:Positron emission tomography (PET) is considered the gold standard for measuring myocardial blood flow in vivo but it is known that respiratory motion can lead to misalignment of the PET and computed tomography (CT) data sets and introduce artifacts in the CT-based attenuation correction (AC) of images. In addi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4788669

    authors: Pourmoghaddas A,Klein R,deKemp RA,Wells RG

    更新日期:2013-02-01 00:00:00

  • Age-dependent dose calculations for common PET radionuclides and brain radiotracers in nonhuman primate computational models.

    abstract:PURPOSE:The combination of nonhuman primates (NHPs) with the state-of-the-art molecular imaging technologies allows for within-subject longitudinal research aiming at gaining new insights into human normal and disease conditions and provides an ideal foundation for future translational studies of new diagnostic tools, ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14333

    authors: Xie T,Chen X,Zaidi H

    更新日期:2020-09-01 00:00:00

  • Compartment modeling of dynamic brain PET--the impact of scatter corrections on parameter errors.

    abstract:PURPOSE:The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897610

    authors: Häggström I,Schmidtlein CR,Karlsson M,Larsson A

    更新日期:2014-11-01 00:00:00

  • Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.

    abstract:PURPOSE:Using a new linear accelerator with high dose rate (800 MU/min), fast MLC motions (5.0 cm/s), fast gantry rotation (15 s/rotation), and 1 cm wide MLCs, we aimed to quantify the effects of complexity, arc number, and fractionation on interplay for breast and lung treatments under target motion. METHODS:To study...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12899

    authors: Netherton T,Li Y,Nitsch P,Shaitelman S,Balter P,Gao S,Klopp A,Muruganandham M,Court L

    更新日期:2018-06-01 00:00:00

  • Evaluation of diffusion models in breast cancer.

    abstract:PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927255

    authors: Panek R,Borri M,Orton M,O'Flynn E,Morgan V,Giles SL,deSouza N,Leach MO,Schmidt MA

    更新日期:2015-08-01 00:00:00

  • Improved quantification of radionuclide uptake using deconvolution and windowed subtraction techniques for scatter compensation in single photon emission computed tomography.

    abstract::A comparison of two methods of scatter compensation in single photon emission computed tomography (SPECT) imaging is made on the basis of improvements in quantification. The methods, scatter-window subtraction and constrained deconvolution of an average point source response function (PSRF), are described; the theoret...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596453

    authors: Yanch JC,Flower MA,Webb S

    更新日期:1990-11-01 00:00:00

  • A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration.

    abstract:PURPOSE:In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. How...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3697524

    authors: Hub M,Thieke C,Kessler ML,Karger CP

    更新日期:2012-04-01 00:00:00

  • Optimization of detector pixel size for stent visualization in x-ray fluoroscopy.

    abstract::Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as smal...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2169907

    authors: Jiang Y,Wilson DL

    更新日期:2006-03-01 00:00:00

  • Characterization of XR-RV3 GafChromic(®) films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors.

    abstract:PURPOSE:To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS:XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4922132

    authors: Farah J,Trianni A,Ciraj-Bjelac O,Clairand I,De Angelis C,Delle Canne S,Hadid L,Huet C,Jarvinen H,Negri A,Novák L,Pinto M,Siiskonen T,Waryn MJ,Knežević Ž

    更新日期:2015-07-01 00:00:00

  • Computerized detection of masses in digital mammograms: analysis of bilateral subtraction images.

    abstract::A computerized scheme is being developed for the detection of masses in digital mammograms. Based on the deviation from the normal architectural symmetry of the right and left breasts, a bilateral subtraction technique is used to enhance the conspicuity of possible masses. The scheme employs two pairs of conventional ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596610

    authors: Yin FF,Giger ML,Doi K,Metz CE,Vyborny CJ,Schmidt RA

    更新日期:1991-09-01 00:00:00

  • Comparing calibration methods of electron beams using plane-parallel chambers with absorbed-dose to water based protocols.

    abstract::Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N(Co)D,w for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1449876

    authors: Stewart KJ,Seuntjens JP

    更新日期:2002-03-01 00:00:00

  • Automatic tumor segmentation in breast ultrasound images using a dilated fully convolutional network combined with an active contour model.

    abstract:PURPOSE:Due to the low contrast, blurry boundaries, and large amount of shadows in breast ultrasound (BUS) images, automatic tumor segmentation remains a challenging task. Deep learning provides a solution to this problem, since it can effectively extract representative features from lesions and the background in BUS i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13268

    authors: Hu Y,Guo Y,Wang Y,Yu J,Li J,Zhou S,Chang C

    更新日期:2019-01-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • Fast dose optimization for rotating shield brachytherapy.

    abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12486

    authors: Cho M,Wu X,Dadkhah H,Yi J,Flynn RT,Kim Y,Xu W

    更新日期:2017-10-01 00:00:00