Beam properties and stability of a flattening-filter free 7 MV beam-an overview.

Abstract:

PURPOSE:Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). METHODS:Dosimetric properties of the 7XU beam were measured in May and September 2011. We present depth dose curves and beam profiles, output factors, and MLC transmission and assess the stability of the measurements. The 7XU beam was commissioned in the Pinnacle[superscript three] treatment planning system (TPS), and modeling results including the spectrum are presented. RESULTS:The percent depth dose curve of the 7XU beam is similar to the flat 6X beam line, with a slightly smaller surface dose. The beam profiles show the characteristic shape of flattening-filter free beams, with deviations between measurements of generally less than 1%. The output factors of the 7XU beam decrease more slowly than for the 6X beam. The MLC transmission is comparable but slightly less for the 7XU beam. The 7XU beam can be adequately modeled by the Pinnacle[superscript three] TPS, with successful dosimetric verification. The spectrum of the 7XU beam has lower photon fluence up to approximately 2.5 MeV and higher fluence beyond, with a slightly higher mean energy. CONCLUSIONS:The 7XU beam has been commissioned for clinical use after successful modeling, stability checks, and dosimetric verification.

journal_name

Med Phys

journal_title

Medical physics

authors

Dzierma Y,Licht N,Nuesken F,Ruebe C

doi

10.1118/1.3703835

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

2595-602

issue

5

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy.

    abstract::Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Sev...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1624755

    authors: Tutar IB,Managuli R,Shamdasani V,Cho PS,Pathak SD,Kim Y

    更新日期:2003-12-01 00:00:00

  • An in-vivo investigation of the therapeutic effect of pulsed focused ultrasound on tumor growth.

    abstract:PURPOSE:High-intensity focused ultrasound (HIFU) has been investigated for ablative therapy and drug enhancement for gene therapy and chemotherapy. The aim of this work is to explore the feasibility of pulsed focused ultrasound (pFUS) for cancer therapy using an in vivo animal model. METHODS:A clinical HIFU system (In...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901352

    authors: Ma CM,Chen X,Cvetkovic D,Chen L

    更新日期:2014-12-01 00:00:00

  • WE-G-211-02: Origins and Development of Magnetic Resonance Imaging.

    abstract::The method of magnetic resonance imaging (MRI) was an extension of nuclear magnetic resonance (NMR) spectroscopy that was enabled by computational systems capable of performing the Fast Fourier Transform. Initially, a diverse group of methods were proposed for producing images with NMR, with the multi-slice spin-warp ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736176

    authors: Clarke G

    更新日期:2012-06-01 00:00:00

  • Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

    abstract:PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. T...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13900

    authors: Liu J,Xu Y,Teymurazyan A,Papandreou Z,Pang G

    更新日期:2020-01-01 00:00:00

  • Compensator models for fluence field modulated computed tomography.

    abstract:PURPOSE:Fluence field modulated computed tomography (FFMCT) presents a novel approach for acquiring CT images, whereby a patient model guides dynamically changing fluence patterns in an attempt to achieve task-based, user-prescribed, regional variations in image quality, while also controlling dose to the patient. This...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4829513

    authors: Bartolac S,Jaffray D

    更新日期:2013-12-01 00:00:00

  • Electron dosimetry based on the absorbed dose to water concept: a comparison of the AAPM TG-51 and DIN 6800-2 protocols.

    abstract::The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1414008

    authors: Dohm OS,Christ G,Nüsslin F,Schüle E,Bruggmoser G

    更新日期:2001-11-01 00:00:00

  • Accelerated helium-ion beams for radiotherapy and stereotactic radiosurgery.

    abstract::A new beam line for radiotherapy and radiosurgery with accelerated helium-ion beams has been set up at the Bevalac. The new treatment room has been equipped with a very precise patient positioner in order to utilize the superior dose localization properties of light-ion beams. The beam spreading and shaping system is ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596696

    authors: Ludewigt BA,Chu WT,Phillips MH,Renner TR

    更新日期:1991-01-01 00:00:00

  • Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.

    abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1591431

    authors: Bucciolini M,Buonamici FB,Mazzocchi S,De Angelis C,Onori S,Cirrone GA

    更新日期:2003-08-01 00:00:00

  • Multigroup discrete ordinates modeling of 125I 6702 seed dose distributions using a broad energy-group cross section representation.

    abstract::Our purpose in this work is to demonstrate that the efficiency of dose-rate computations in 125I brachytherapy, using multigroup discrete ordinates radiation transport simulations, can be significantly enhanced using broad energy group cross sections without a loss of accuracy. To this end, the DANTSYS multigroup disc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1429238

    authors: Daskalov GM,Baker RS,Rogers DW,Williamson JF

    更新日期:2002-02-01 00:00:00

  • Characteristics of metal-plate/film detectors at therapy energies. II. Detective quantum efficiency.

    abstract::Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal-plate/film portal detectors are reported for the Co-60 and Linac 10 MV spectra. The detectors consist of a double-emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598437

    authors: Falco T,Fallone BG

    更新日期:1998-12-01 00:00:00

  • Quantification of body-torso-wide tissue composition on low-dose CT images via automatic anatomy recognition.

    abstract:PURPOSE:Quantification of body composition plays an important role in many clinical and research applications. Radiologic imaging techniques such as Dual-energy X-ray absorptiometry (DXA), magnetic resonance imaging (MRI), and computed tomography (CT) imaging make accurate quantification of the body composition possibl...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13373

    authors: Liu T,Udupa JK,Miao Q,Tong Y,Torigian DA

    更新日期:2019-03-01 00:00:00

  • Technical Note: Virtual phantom analyses for preprocessing evaluation and detection of a robust feature set for MRI-radiomics of the brain.

    abstract:PURPOSE:The purpose of the paper was to use a virtual phantom to identify a set of radiomic features from T1-weighted and T2-weighted magnetic resonance imaging (MRI) of the brain which is stable to variations in image acquisition parameters and to evaluate the effect of image preprocessing on radiomic features stabili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13834

    authors: Bologna M,Corino V,Mainardi L

    更新日期:2019-11-01 00:00:00

  • Positional radiotherapy beam dosimetry using a laser heated thermoluminescent plate.

    abstract::A 4-W, laser-based system for the positional readout of thermoluminescent (TL) plates was utilized to obtain dose profiles for a 60Co radiotherapy beam. Experimentally obtained glow curves for LiF resulting from the rapid heating rates characteristic of laser heating agreed well with results predicted using a first-or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596580

    authors: Kearfott KJ,Grupen-Shemansky ME

    更新日期:1990-05-01 00:00:00

  • Eigencolor radiochromic film dosimetry.

    abstract:PURPOSE:The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications. METHODS:The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thicknes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14742

    authors: Bouchard H,Billas I,Subie A,Duane S

    更新日期:2021-02-01 00:00:00

  • Introduction of heat map to fidelity assessment of compressed CT images.

    abstract:PURPOSE:This study aimed to introduce heat map, a graphical data presentation method widely used in gene expression experiments, to the presentation and interpretation of image fidelity assessment data of compressed computed tomography (CT) images. METHODS:The authors used actual assessment data that consisted of five...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3611046

    authors: Lee H,Kim B,Kim KJ,Seo J,Park S,Shin YG,Lee KH

    更新日期:2011-08-01 00:00:00

  • Feasibility of a simple method of hybrid collimation for megavoltage grid therapy.

    abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801902

    authors: Almendral P,Mancha PJ,Roberto D

    更新日期:2013-05-01 00:00:00

  • SU-E-T-217: Automated Data Mining of Lung SBRT Cases for Predicting Dosimetric Indices in Prospective Plans.

    abstract:PURPOSE:To develop an automated technique for evaluating lung stereotactic body radiotherapy (SBRT) plan quality and predicting achievable lung dose constraints. METHODS:We examined the workflow scripting capabilities of a radiation oncology software package (MIM Software Inc) for automatically generating mean dose gr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735279

    authors: Atwood T,Xing L,Hristov D

    更新日期:2012-06-01 00:00:00

  • Technical Note: Characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM.

    abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930245

    authors: Price RG,Kadbi M,Kim J,Balter J,Chetty IJ,Glide-Hurst CK

    更新日期:2015-10-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • SU-E-T-567: Improve Dose Conformity with IMRT Using Shorter Source to Tumor Distance.

    abstract:PURPOSE:To reduce the potential of late toxicity (tissue necrosis and cognitive function loss) from brain radiotherapy, we studied a novel planning technique for MLC-equipped linear accelerators (LINACS) that reduces the high doses delivered outside the PTV, enhancing radiation dose conformity. METHODS:The feasibility...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735656

    authors: Yang W,Sandler H,Fraass B

    更新日期:2012-06-01 00:00:00

  • An automated procedure for the quality assurance of electron beam output and energy.

    abstract::In this article, we report on the development of a simple and accurate method for quality assurance of electron beam output and energy. Aluminum disks of thicknesses d(max) or d50 of the particular electron energy are positioned sequentially over a parallel-plate ion chamber and the ratio of the two signals is compare...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1688040

    authors: Woo MK,Videla NG

    更新日期:2004-05-01 00:00:00

  • A K alpha dual energy x-ray source for coronary angiography.

    abstract::The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 line...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596648

    authors: Manning HL,Shefer RE,Klinkowstein RE,Mistretta CA

    更新日期:1991-09-01 00:00:00

  • Monte Carlo dosimetry for 103Pd, 125I, and 131Cs ocular brachytherapy with various plaque models using an eye phantom.

    abstract:PURPOSE:To investigate dosimetry for ocular brachytherapy for a range of eye plaque models containing(103)Pd, (125)I, or (131)Cs seeds with model-based dose calculations. METHODS:Five representative plaque models are developed based on a literature review and are compared to the standardized COMS plaque, including pla...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4864474

    authors: Lesperance M,Martinov M,Thomson RM

    更新日期:2014-03-01 00:00:00

  • Radiologic validation of a fast neutron multileaf collimator.

    abstract::Teletherapy with high linear energy transfer radiations (LET), perhaps more than with low LET types, requires careful beam collimation to limit effects to normal structures. Intensity modulated techniques may also hold promise in this regard. Accordingly, a remote computer-controlled, high-resolution multileaf collima...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2760026

    authors: Farr JB,Maughan RL,Yudelev M,Blosser E,Brandon J,Horste T,Forman JD

    更新日期:2007-09-01 00:00:00

  • SU-E-T-178: Optically Stimulated Luminescence (OSL) Dosimetry: A Study of A-Al2O3:C Assessed by PENELOPE Monte Carlo Simulation.

    abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735237

    authors: Nicolucci P,Schuch F

    更新日期:2012-06-01 00:00:00

  • A methodology to determine margins by EPID measurements of patient setup variation and motion as applied to immobilization devices.

    abstract::Assessment of clinic and site specific margins are essential for the effective use of three-dimensional and intensity modulated radiation therapy. An electronic portal imaging device (EPID) based methodology is introduced which allows individual and population based CTV-to-PTV margins to be determined and compared wit...

    journal_title:Medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1118/1.1800712

    authors: Prisciandaro JI,Frechette CM,Herman MG,Brown PD,Garces YI,Foote RL

    更新日期:2004-11-01 00:00:00

  • An optimized ultrasound detector for photoacoustic breast tomography.

    abstract:PURPOSE:Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further, because the ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792462

    authors: Xia W,Piras D,van Hespen JC,van Veldhoven S,Prins C,van Leeuwen TG,Steenbergen W,Manohar S

    更新日期:2013-03-01 00:00:00

  • Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.

    abstract:PURPOSE:Plastic scintillation detectors are used for dosimetry in small radiation fields with high dose gradients, e.g., provided by β-emitting sources like 106 Ru/106 Rh eye plaques. A drawback is a background signal caused by Cerenkov radiation generated by electrons passing the optical fibers (light guides) of this ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12374

    authors: Eichmann M,Thomann B

    更新日期:2017-09-01 00:00:00

  • An alternative VMAT with prior knowledge about the type of leaf motion utilizing projection method for concave targets.

    abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3173815

    authors: Hoegele W,Loeschel R,Zygmanski P

    更新日期:2009-08-01 00:00:00

  • Brain SPECT with short focal-length cone-beam collimation.

    abstract::Single-photon emission-computed tomography (SPECT) imaging of deep brain structures is compromised by loss of photons due to attenuation. We have previously shown that a centrally peaked collimator sensitivity function can compensate for this phenomenon, increasing sensitivity over most of the brain. For dual-head ins...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1929208

    authors: Park MA,Moore SC,Kijewski MF

    更新日期:2005-07-01 00:00:00