Abstract:
:The use of characteristic-line radiation from rare-earth targets bombarded by high-energy (up to 1 MeV) electron beams has been evaluated as an x-ray source for dual energy K-edge subtraction imaging of the human coronary arteries. Two characteristic-line x-ray sources, one using the split K alpha 1 and K alpha 2 lines of lanthanum excited by a high-energy electron beam and the other using the K alpha lines of barium and cerium, were studied. A Monte Carlo electron-photon simulation was used to calculate x-ray spectra and energy deposition profiles from targets of these elements bombarded by electrons in the energy range 140 keV to 1 MeV. A general dual-energy imaging model was developed that used these calculated source spectra to numerically investigate the dependence of the subtraction image signal-to-noise ratio on such factors as the ratio of K-line to x-ray continuum yield, continuum spectral shape, x-ray filtering, and detector response. A signal averaging technique for enhancing the signal-to-noise ratio was also evaluated. The results of these calculations were used to identify an optimum electron beam, target, filter, and detector configuration. A compact electron accelerator capable of providing the required electron beam parameters was designed. Calculations indicate that under ideal conditions the optimized system would be capable of imaging 2 mg/cm2 of iodine contrast agent in 20 g/cm2 of tissue with a signal-to-noise ratio of 5, a detector pixel size of 0.25 mm2, and a total image acquisition time of 10 ms. These parameters are consistent with those needed to image the human coronary arteries after an intravenous injection of iodine contrast agent. These capabilities, along with the relatively modest hardware requirements of this system, make it attractive as an x-ray source for dual energy transvenous coronary angiography.
journal_name
Med Physjournal_title
Medical physicsauthors
Manning HL,Shefer RE,Klinkowstein RE,Mistretta CAdoi
10.1118/1.596648subject
Has Abstractpub_date
1991-09-01 00:00:00pages
880-93issue
5eissn
0094-2405issn
2473-4209journal_volume
18pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735351
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:This article aims to introduce a novel algorithm for fast beam angle selection in intensity modulated radiotherapy (IMRT). METHODS:The algorithm models the optimization problem as a beam angle ranking problem and chooses suitable beam angles according to their rank. A new parameter called "beam intensity profi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3517866
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:Radiotherapy is an effective treatment for many types of cancer in clinical settings. Gel dosimetry has the potential to record three-dimensional (3D) dose distribution compared to a conventional ion chamber. As the elasticity of the gel is altered after irradiation due to gel polymerization, we aim to measure ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14020
更新日期:2020-03-01 00:00:00
abstract::A proton beam is extracted from the 200-MeV linear accelerator at the Fermi National Accelerator Laboratory to investigate the efficacy of proton radiography in medical diagnosis. Fluence rates from 2 X 10(3) to 2 X 10(5) protons/cm2s over a 28-cm diameter field are obtained with a full width at half-maximum beam-ener...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594426
更新日期:1978-05-01 00:00:00
abstract::Most detectors in current positron emission tomography (PET) scanners and prototypes use lutetium oxyorthosilicate (LSO) or lutetium yttrium oxyorthosilicate (LYSO) scintillators. The aim of this work is to provide a complete set of background energy spectra, due to the scintillator intrinsic radioactivity, for a wide...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14729
更新日期:2021-01-21 00:00:00
abstract:PURPOSE:We propose a new method for efficient particle transportation in voxelized geometry for Monte Carlo simulations. We describe its use for calculating dose distribution in CT images for radiation therapy. MATERIAL AND METHODS:The proposed approach, based on an implicit volume representation named segmented volum...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2884854
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR20,10) for a square field of 10 x 10 cm2 and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3197062
更新日期:2009-09-01 00:00:00
abstract::We describe the use of a graphical mathematical spreadsheet programming environment which can be used to simulate the acquisition and reconstruction processes of an x-ray computed tomography (CT) machine. The simulation is used to study the effect of photon counting statistics on the noise in the reconstructed image. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598654
更新日期:1999-08-01 00:00:00
abstract:PURPOSE:To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). METHODS:Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963213
更新日期:2016-10-01 00:00:00
abstract::The use of magnetic resonance imaging as a readout method for polymer gel dosimetry commonly involves long imaging sessions, particularly when high spatial resolution is required in all three dimensions, for the investigation of dose distributions with steep dose gradients and stringent dose delivery specifications. I...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2065367
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. METHODS:Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4830427
更新日期:2013-12-01 00:00:00
abstract:PURPOSE:To investigate the optimal use of XR-RV3 GafChromic(®) films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. METHODS:XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patie...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4922132
更新日期:2015-07-01 00:00:00
abstract::Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy dri...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.599033
更新日期:2000-07-01 00:00:00
abstract::A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model I125 (model 6711) and Pd103 (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3002412
更新日期:2008-12-01 00:00:00
abstract::We compare the results of absorbed dose determined at reference conditions according to the AAPM TG-21 dose calibration protocol and the new AAPM TG-51 protocol. The AAPM TG-21 protocol for absorbed dose calibration is based on ionization chambers having exposure calibration factors for 60Co gamma rays, N(x). The new ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598999
更新日期:2000-06-01 00:00:00
abstract:PURPOSE:The need for an accurate lesion segmentation tool in 18FDG PET is a prerequisite for the estimation of lesion response to therapy, for radionuclide dosimetry, and for the application of 18FDG PET to radiotherapy planning. In this work, the authors have developed an iterative method based on a mathematical fit d...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3222732
更新日期:2009-10-01 00:00:00
abstract:PURPOSE:Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-AR...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4865778
更新日期:2014-03-01 00:00:00
abstract::This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595995
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14208
更新日期:2020-08-01 00:00:00
abstract:PURPOSE:To compare and evaluate intensity-based registration methods for computation of serial x-ray mammogram correspondence. METHODS:X-ray mammograms were simulated from MRIs of 20 women using finite element methods for modeling breast compressions and employing a MRI/x-ray appearance change model. The parameter con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3457470
更新日期:2010-09-01 00:00:00
abstract:PURPOSE:Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4950722
更新日期:2016-06-01 00:00:00
abstract::Depending on the clinical application, it is frequently necessary to tilt the gantry of an x-ray CT system with respect to the patient and couch. For single-slice fan-beam systems, tilting the gantry introduces no errors or artifacts. Most current systems, however, are helical multislice systems with up to 16 slices. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1625443
更新日期:2003-12-01 00:00:00
abstract::The purpose of the present study is to characterize electron contamination in photon beams in different clinical situations. Variations with field size, beam modifier (tray, shaping block) and source-surface distance (SSD) were studied. Percentage depth dose measurements with and without a purging magnet and replacing...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1895793
更新日期:2005-05-01 00:00:00
abstract:PURPOSE:To investigate energy deposition in glandular tissues of the breast on macro- and microscopic length scales in the context of mammography. METHODS:Multiscale mammography models of breasts are developed, which include segmented, voxelized macroscopic tissue structure as well as nine regions of interest (ROIs) e...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13372
更新日期:2019-03-01 00:00:00
abstract::The propagation of noise in digitized images arrived at by algebraic manipulation of two images has been investigated. The algebraic manipulations investigated were logarithmic subtraction, linear subtraction, and division of the two images. The two images were identical except for the presence of a contrast-adding co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595289
更新日期:1983-01-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of using the high Zeff storage phosphor material BaFBrI:Eu2+ in conjunction with the low Zeff storage phosphor material KCl:Eu2+ for simultaneous proton dose and linear energy transfer (LET) measurements by 1) measuring the fundamental optical and dosimetric properties of BaFBrI:E...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14748
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:Radiation therapy is often delivered by multiple sequential treatment plans. For an accurate radiobiological evaluation of the overall treatment, fractionation corrections to each dose distribution must be applied before summing the three-dimensional dose matrix of each plan since the simpler approach of perfor...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4792636
更新日期:2013-03-01 00:00:00
abstract:PURPOSE:The purpose of this study was to quantitatively characterize the fundamental aspects of image quality (IQ) associated with different computed tomography (CT) reconstruction algorithms, the resolution, noise texture, noise magnitude per dose, and use those data to devise a methodology to match IQ between differe...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12554
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:In recent years, laser-based acceleration of charged particles has rapidly progressed and medical applications, e.g., in radiotherapy, might become feasible in the coming decade. Requirements are monoenergetic particle beams with long-term stable and reproducible properties as well as sufficient particle intens...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3301598
更新日期:2010-04-01 00:00:00
abstract:PURPOSE:X-ray fluorescence (XRF) is a promising technique with sufficient specificity and sensitivity for identifying and quantifying features in small samples containing high atomic number (Z) materials such as iodine, gadolinium, and gold. In this study, the feasibility of applying XRF to early breast cancer diagnosi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4863510
更新日期:2014-03-01 00:00:00