Tomosynthesis-based localization of radioactive seeds in prostate brachytherapy.

Abstract:

:Accurately assessing the quality of prostate brachytherapy intraoperatively would be valuable for improved clinical outcome by ensuring the delivery of a prescribed tumoricidal radiation dose to the entire prostate gland. One necessary step towards this goal is the robust and rapid localization of implanted seeds. Several methods have been developed to locate seeds from x-ray projection images, but they fail to detect completely-overlapping seeds, thus necessitating manual intervention. To overcome this limitation, we have developed a new method where (1) a three-dimensional volume is reconstructed from x-ray projection images using a brachytherapy-specific tomosynthesis reconstruction algorithm with built-in blur compensation and (2) the seeds are located in this reconstructed volume. In contrast to other projection-based methods, our method can detect completely overlapping seeds. Our simulation results indicate that we can locate all implanted seeds in the prostate using a tomosynthesis angle of 30 degrees and seven projection images. The mean localization error is 1.27 mm for a case with 100 seeds. We have also tested our method using a prostate phantom with 61 implanted seeds and succeeded in locating all seeds automatically. We believe this new method can be useful for the intraoperative quality assessment of prostate brachytherapy in the future.

journal_name

Med Phys

journal_title

Medical physics

authors

Tutar IB,Managuli R,Shamdasani V,Cho PS,Pathak SD,Kim Y

doi

10.1118/1.1624755

subject

Has Abstract

pub_date

2003-12-01 00:00:00

pages

3135-42

issue

12

eissn

0094-2405

issn

2473-4209

journal_volume

30

pub_type

杂志文章
  • Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator.

    abstract:PURPOSE:Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4946815

    authors: Hansen R,Ravkilde T,Worm ES,Toftegaard J,Grau C,Macek K,Poulsen PR

    更新日期:2016-05-01 00:00:00

  • ALTIS: A fast and automatic lung and trachea CT-image segmentation method.

    abstract:PURPOSE:The automated segmentation of each lung and trachea in CT scans is commonly taken as a solved problem. Indeed, existing approaches may easily fail in the presence of some abnormalities caused by a disease, trauma, or previous surgery. For robustness, we present ALTIS (implementation is available at http://lids....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13773

    authors: Sousa AM,Martins SB,Falcão AX,Reis F,Bagatin E,Irion K

    更新日期:2019-11-01 00:00:00

  • Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722967

    authors: Catuzzo P,Zenone F,Aimonetto S,Peruzzo A,Casanova Borca V,Pasquino M,Franco P,La Porta MR,Ricardi U,Tofani S

    更新日期:2012-07-01 00:00:00

  • Electron dose calculation using multiple-scattering theory. A. Gaussian multiple-scattering theory.

    abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596166

    authors: Jette D

    更新日期:1988-03-01 00:00:00

  • Half-scan cone-beam CT fluoroscopy with multiple x-ray sources.

    abstract::To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan F...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1381549

    authors: Liu Y,Liu H,Wang Y,Wang G

    更新日期:2001-07-01 00:00:00

  • Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom.

    abstract:PURPOSE:Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCT...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4870956

    authors: Moyers MF

    更新日期:2014-06-01 00:00:00

  • Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.

    abstract::The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its p...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2795842

    authors: Chetty IJ,Curran B,Cygler JE,DeMarco JJ,Ezzell G,Faddegon BA,Kawrakow I,Keall PJ,Liu H,Ma CM,Rogers DW,Seuntjens J,Sheikh-Bagheri D,Siebers JV

    更新日期:2007-12-01 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00

  • Direct aperture deformation: an interfraction image guidance strategy.

    abstract::A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation matrix can be derived that associates the planning image set and the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2374675

    authors: Feng Y,Castro-Pareja C,Shekhar R,Yu C

    更新日期:2006-12-01 00:00:00

  • Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.

    abstract::Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing nov...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4941014

    authors: Mehranian A,Arabi H,Zaidi H

    更新日期:2016-03-01 00:00:00

  • Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator.

    abstract::Charge coupled devices (CCDs) are being increasingly used in radiation therapy for dosimetric purposes. However, CCDs are sensitive to stray radiation. This effect induces transient noise. Radiation-induced noise strongly alters the image and therefore limits its quantitative analysis. The purpose of this work is to c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2975147

    authors: Archambault L,Briere TM,Beddar S

    更新日期:2008-10-01 00:00:00

  • Estimated spectrum of a 4-MV therapeutic beam.

    abstract::We have made a comparative investigation of the estimated spectra obtained by the Laplace transform analysis of the transmitted exposure data measured in an absorption study of a 4-MV x-ray beam. Four transform pair models currently used with this method have been evaluated. It has been determined that the Archer-Wagn...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595878

    authors: Ahuja SD,Steward PG,Roy TS,Slessinger ED

    更新日期:1986-05-01 00:00:00

  • The potential role of positron emission mammography for detection of breast cancer. A phantom study.

    abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1287439

    authors: Raylman RR,Majewski S,Wojcik R,Weisenberger AG,Kross B,Popov V,Bishop HA

    更新日期:2000-08-01 00:00:00

  • The delta envelope: a technique for dose distribution comparison.

    abstract::The gamma index is a tool that compares a dose distribution with a reference distribution by combining dose-difference and distance-to-agreement criteria. It has been widely used for ten years despite its high computational cost. This cost is due to both a search process for each reference point and the necessity to r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3070546

    authors: Blanpain B,Mercier D

    更新日期:2009-03-01 00:00:00

  • Deadtime correction for two multihead Anger cameras in 131I dual-energy-window-acquisition mode.

    abstract::Two side-by-side energy windows, one at the photopeak and one at lower energy, are sometimes employed in quantitative SPECT studies. We measured the count-rate losses at moderately high activities of 131I for two multihead Anger cameras in such a dual-window-acquisition mode by imaging a decaying source composed of tw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598162

    authors: Koral KF,Zasadny KR,Ackermann RJ,Ficaro EP

    更新日期:1998-01-01 00:00:00

  • Validation of the Gatortail method for accurate sizing of pulmonary vessels from 3D medical images.

    abstract:PURPOSE:Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12580

    authors: O'Dell WG,Gormaley AK,Prida DA

    更新日期:2017-12-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • Characterization of the nanoDot OSLD dosimeter in CT.

    abstract:PURPOSE:The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914398

    authors: Scarboro SB,Cody D,Alvarez P,Followill D,Court L,Stingo FC,Zhang D,McNitt-Gray M,Kry SF

    更新日期:2015-04-01 00:00:00

  • Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging.

    abstract:PURPOSE:The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4916802

    authors: Yu L,Vrieze TJ,Leng S,Fletcher JG,McCollough CH

    更新日期:2015-05-01 00:00:00

  • Determination of the photon spectrum of a clinical accelerator.

    abstract::An experiment to determine the peak of the energy spectrum of the photon beam from a Toshiba LMR-15 medical linear accelerator is described. It is found that the flattening filters removed much of the bremsstrahlung spectrum below approximately 1 MeV, resulting in a photon spectrum which peaks around 1.2 MeV. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595582

    authors: Brownridge J,Samnick S,Stiles P,Tipton P,Veselka J,Yeh N

    更新日期:1984-11-01 00:00:00

  • SU-E-T-142: Evaluation of the Energy Dependence of Gafchromic EBT3 Film for Electron Beams.

    abstract:PURPOSE:To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS:We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735200

    authors: Inoue T,Sugimoto S,Fukata K,Kurokawa C,Ozawa S,Sasai K

    更新日期:2012-06-01 00:00:00

  • Automated segmentation of lungs with severe interstitial lung disease in CT.

    abstract:PURPOSE:Accurate segmentation of lungs with severe interstitial lung disease (ILD) in thoracic computed tomography (CT) is an important and difficult task in the development of computer-aided diagnosis (CAD) systems. Therefore, we developed in this study a texture analysis-based method for accurate segmentation of lung...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3222872

    authors: Wang J,Li F,Li Q

    更新日期:2009-10-01 00:00:00

  • Sci-Sat AM(1): Imaging-01: Tumour and normal tissue T2 and ADC distributions for a mouse model at 9.4T.

    abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965985

    authors: Larocque M,Syme A,Fallone BG

    更新日期:2008-07-01 00:00:00

  • On the efficiency of photon beam treatment head simulations.

    abstract::The paper presents a theoretical derivation of the photon fluence simulation efficiency in photon beam treatment head simulations without and with bremsstrahlung splitting. The expressions obtained provide a rigorous explanation of the efficiency dependence on scoring zone size and splitting number and explain the lar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1943808

    authors: Kawrakow I

    更新日期:2005-07-01 00:00:00

  • X-ray phase contrast imaging of the breast: analysis of tissue simulating materials.

    abstract:PURPOSE:Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4794503

    authors: Vedantham S,Karellas A

    更新日期:2013-04-01 00:00:00

  • SU-E-T-162: Rapid Assessment of Cyberknife IRIS Variable Collimator Performance Using a Commercial Diode Array.

    abstract:PURPOSE:To describe an efficient method for verifying the size and centering of the radiation field from the Cyberknife IRIS variable collimator with sub-millimeter accuracy using a general purpose commercially available diode array. METHODS:We present a technique using a conventional diode array (Sun Nuclear Profiler...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735220

    authors: Gibbs G,White G,Bulz G

    更新日期:2012-06-01 00:00:00

  • Novel scintillation detector design and performance for proton radiography and computed tomography.

    abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4939255

    authors: Bashkirov VA,Schulte RW,Hurley RF,Johnson RP,Sadrozinski HF,Zatserklyaniy A,Plautz T,Giacometti V

    更新日期:2016-02-01 00:00:00

  • A fast double template convolution isocenter evaluation algorithm with subpixel accuracy.

    abstract:PURPOSE:To design a fast Winston Lutz (fWL) algorithm for accurate analysis of radiation isocenter from images without edge detection or center of mass calculations. METHODS:An algorithm has been developed to implement the Winston Lutz test for mechanical/ radiation isocenter agreement using an electronic portal imagi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3524227

    authors: Winey B,Sharp G,Bussière M

    更新日期:2011-01-01 00:00:00

  • Eddy current disruption: effect on nuclear magnetic resonance coil impedance and power loss.

    abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596336

    authors: Harpen MD

    更新日期:1989-09-01 00:00:00

  • SU-E-I-38: Optimizing CT Slice Width Measurements.

    abstract:PURPOSE:For almost four decades bead and wire ramps have been used in the evaluation of slice width as part of QA testing for CT scanners. While each of these approaches have been recognized and accepted as reliable, in this paper we investigate the differences, advantages and limitations of these tools. Moreover, we s...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734753

    authors: Marteinsdóttir M,Olafsdottir H,Fredriksson J,Andresson A,Healy A,Kristbjornsson A,Kristinsson S,Levy J,Goodenough D

    更新日期:2012-06-01 00:00:00