Automatic treatment planning based on three-dimensional dose distribution predicted from deep learning technique.

Abstract:

PURPOSE:To develop an automated treatment planning strategy for external beam intensity-modulated radiation therapy (IMRT), including a deep learning-based three-dimensional (3D) dose prediction and a dose distribution-based plan generation algorithm. METHODS AND MATERIALS:A residual neural network-based deep learning model is trained to predict a dose distribution based on patient-specific geometry and prescription dose. A total of 270 head-and-neck cancer cases were enrolled in this study, including 195 cases in the training dataset, 25 cases in the validation dataset, and 50 cases in the testing dataset. All patients were treated with IMRT with a variety of different prescription patterns. The model input consists of CT images and contours delineating the organs at risk (OARs) and planning target volumes (PTVs). The algorithm output is trained to predict the dose distribution on the CT image slices. The obtained prediction model is used to predict dose distributions for new patients. Then, an optimization objective function based on these predicted dose distributions is created for automatic plan generation. RESULTS:Our results demonstrate that the deep learning method can predict clinically acceptable dose distributions. There is no statistically significant difference between prediction and real clinical plan for all clinically relevant dose-volume histogram (DVH) indices, except brainstem, right and left lens. However, the predicted plans were still clinically acceptable. The results of plan generation show no statistically significant differences between the automatic generated plan and the predicted plan except PTV70.4 , but the difference is only 0.5% which is still clinically acceptable. CONCLUSION:This study developed a new automated radiotherapy treatment planning system based on 3D dose prediction and 3D dose distribution-based optimization. It is a promising approach for realizing automated treatment planning in the future.

journal_name

Med Phys

journal_title

Medical physics

authors

Fan J,Wang J,Chen Z,Hu C,Zhang Z,Hu W

doi

10.1002/mp.13271

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

370-381

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

46

pub_type

杂志文章
  • Noninvasive x-ray tube current measurement.

    abstract::A clamp-on current probe utilizing the Hall effect was used to determine x-ray tube current. This noninvasive technique was compared to two other methods of mA measurement: the Machlett Dynalyzer and the mR/mAs linearity method. Three diagnostic x-ray units were used in the comparison; two modern three-phase rooms and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596080

    authors: Atherton JV,Nickoloff EL

    更新日期:1987-03-01 00:00:00

  • Validation for 2D/3D registration. I: A new gold standard data set.

    abstract:PURPOSE:In this article, the authors propose a new gold standard data set for the validation of two-dimensional/three-dimensional (2D/3D) and 3D/3D image registration algorithms. METHODS:A gold standard data set was produced using a fresh cadaver pig head with attached fiducial markers. The authors used several imagin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553402

    authors: Pawiro SA,Markelj P,Pernus F,Gendrin C,Figl M,Weber C,Kainberger F,Nöbauer-Huhmann I,Bergmeister H,Stock M,Georg D,Bergmann H,Birkfellner W

    更新日期:2011-03-01 00:00:00

  • A statistical analysis of ionometrically measured 6-MV x-ray beam parameters.

    abstract::A statistical analysis has been made of ionometrically measured parameters related to the central-axis output, the beam symmetry, the beam flatness, and the depth dose for the 6-MV x-ray beam from the Therac-6 linear accelerator. The means and coefficients of variation of the measurements are determined on a monthly b...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595642

    authors: Dawson DJ,Gribble MA

    更新日期:1984-09-01 00:00:00

  • Validation of GPU-accelerated superposition-convolution dose computations for the Small Animal Radiation Research Platform.

    abstract:PURPOSE:The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on-board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)-accelerated Superposition-Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12862

    authors: Cho N,Tsiamas P,Velarde E,Tryggestad E,Jacques R,Berbeco R,McNutt T,Kazanzides P,Wong J

    更新日期:2018-05-01 00:00:00

  • Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac.

    abstract:PURPOSE:Linac-magnetic resonance (MR) systems have been proposed in order to achieve realtime image guided radiotherapy. The design of a new linac-MR system with the in-line 6 MV linac generating x-rays along the symmetry axis of an open MR imager is outlined. This new design allows for a greater MR field strength to a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481513

    authors: St Aubin J,Santos DM,Steciw S,Fallone BG

    更新日期:2010-09-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • A novel approach to evaluate spatial resolution of MRI clinical images for optimization and standardization of breast screening protocols.

    abstract:PURPOSE:Stringent quality assurance is required in MRI breast screening to ensure that different scanners and imaging protocols reach similar diagnostic performance. The authors propose a methodology, based on power spectrum analysis (PSA), to evaluate spatial resolution in clinical images. To demonstrate this approach...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966704

    authors: Borri M,Scurr ED,Richardson C,Usher M,Leach MO,Schmidt MA

    更新日期:2016-12-01 00:00:00

  • Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors.

    abstract::Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are pre...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198168

    authors: Zilio VO,Joneja OP,Popowski Y,Rosenfeld A,Chawla R

    更新日期:2006-06-01 00:00:00

  • An alternative VMAT with prior knowledge about the type of leaf motion utilizing projection method for concave targets.

    abstract::The authors present an alternative approach to inverse planning optimization and apply it to volumetric modulated are therapy (VMAT) in one rotation with a prior knowledge about the type of leaf motions. The optimization is based on the projection theorem in inner product spaces. MLC motion is directly considered in t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3173815

    authors: Hoegele W,Loeschel R,Zygmanski P

    更新日期:2009-08-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00

  • Rigid 2D/3D slice-to-volume registration and its application on fluoroscopic CT images.

    abstract::Registration of single slices from FluoroCT, CineMR, or interventional magnetic resonance imaging to three dimensional (3D) volumes is a special aspect of the two-dimensional (2D)/3D registration problem. Rather than digitally rendered radiographs (DRR), single 2D slice images obtained during interventional procedures...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2401661

    authors: Birkfellner W,Figl M,Kettenbach J,Hummel J,Homolka P,Schernthaner R,Nau T,Bergmann H

    更新日期:2007-01-01 00:00:00

  • Dosimetric effects of needle divergence in prostate seed implant using 125I and 103Pd radioactive seeds.

    abstract::In prostate seed implants, radioactive seeds are implanted into the prostate through a guiding needle with the help of a template and real-time imaging. The ideal locations of the guiding needles and the relative positions of the seeds in each needle are determined before the implantation under the assumption that the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598971

    authors: Nath S,Chen Z,Yue N,Trumpore S,Peschel R

    更新日期:2000-05-01 00:00:00

  • Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneities.

    abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597303

    authors: Jursinic PA,Podgorsak MB,Paliwal BR

    更新日期:1994-03-01 00:00:00

  • Comparison of proton and x-ray conformal dose distributions for radiosurgery applications.

    abstract::Highly focused dose distributions for radiosurgery applications are successfully achieved using either multiple static high-energy particle beams or multiple-arc circular x-ray beams from a linac. It has been suggested that conformal x-ray techniques using dynamically shaped beams with a moving radiation source would ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597654

    authors: Serago CF,Thornton AF,Urie MM,Chapman P,Verhey L,Rosenthal SJ,Gall KP,Niemierko A

    更新日期:1995-12-01 00:00:00

  • Multipinhole collimator with 20 apertures for a brain SPECT application.

    abstract:PURPOSE:Several new technologies for single photon emission computed tomography (SPECT) instrumentation with parallel-hole collimation have been proposed to improve detector sensitivity and signal collection efficiency. Benefits from improved signal efficiency include shorter acquisition times and lower dose requiremen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897567

    authors: Lee TC,Ellin JR,Huang Q,Shrestha U,Gullberg GT,Seo Y

    更新日期:2014-11-01 00:00:00

  • Imaging of radiation dose by visible color development in ferrous-agarose-xylenol orange gels.

    abstract::Imaging of radiation dose distribution in gel phantoms by magnetic resonance techniques has previously been reported. In this paper a method of producing gels in which the distributions of radiation dose can also be visualized as a color change is reported. The color developed depends qualitatively and quantitatively ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596676

    authors: Appleby A,Leghrouz A

    更新日期:1991-03-01 00:00:00

  • Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects.

    abstract:PURPOSE:To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. METHODS:In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930798

    authors: Bouchard H,Kamio Y,Palmans H,Seuntjens J,Duane S

    更新日期:2015-10-01 00:00:00

  • WE-F-211-01: The Evolving Landscape of Scientific Publishing.

    abstract::The dissemination of scientific advances has changed little since the first peer-reviewed journal was published in 1665 - that is, until this past decade. The print journal, delivered by mail and stored on office shelves and in library reading rooms around the world, has been transformed by immediate, on-demand access...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736173

    authors: Armato S,Hendee W,Marshall C,Curran B

    更新日期:2012-06-01 00:00:00

  • An investigation into the robustness of dynamically collimated proton therapy treatments.

    abstract:PURPOSE:To investigate the dosimetric robustness of dynamically collimated proton therapy (DCPT) treatment plans delivered using a dynamic collimation system (DCS) with respect to random uncertainties in beam spot and collimator position as well as systematic offsets in the DCS mounting alignment. This work also demons...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14208

    authors: Smith BR,Hyer DE,Culberson WS

    更新日期:2020-08-01 00:00:00

  • Reference dataset of users' photon beam modeling parameters for the Eclipse, Pinnacle, and RayStation treatment planning systems.

    abstract:PURPOSE:The aim of this work was to provide a novel description of how the radiotherapy community configures treatment planning system (TPS) radiation beam models for clinically used treatment machines. Here we describe the results of a survey of self-reported TPS beam modeling parameter values across different C-arm l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13892

    authors: Glenn MC,Peterson CB,Followill DS,Howell RM,Pollard-Larkin JM,Kry SF

    更新日期:2020-01-01 00:00:00

  • Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner.

    abstract:PURPOSE:Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and dete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943632

    authors: Patel T,Peppard H,Williams MB

    更新日期:2016-04-01 00:00:00

  • Verification of absorbed dose determined with plane-parallel chambers in clinical electron beams following AAPM Task Group 39 protocol using ferrous sulphate dosimetry.

    abstract::The absorbed dose values determined with the Exradin and PTW-Markus plane-parallel chambers were compared to the values obtained with the ferrous sulphate dosimetry for a number of the Philips SL25 and the Therac 20 electron beams. For the plane-parallel chambers, the cavity-gas calibration factor Ngaspp, was derived ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597800

    authors: Xu Z,Li H,Almond PR,Guan TY

    更新日期:1996-03-01 00:00:00

  • An in-vivo investigation of the therapeutic effect of pulsed focused ultrasound on tumor growth.

    abstract:PURPOSE:High-intensity focused ultrasound (HIFU) has been investigated for ablative therapy and drug enhancement for gene therapy and chemotherapy. The aim of this work is to explore the feasibility of pulsed focused ultrasound (pFUS) for cancer therapy using an in vivo animal model. METHODS:A clinical HIFU system (In...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901352

    authors: Ma CM,Chen X,Cvetkovic D,Chen L

    更新日期:2014-12-01 00:00:00

  • A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.

    abstract:PURPOSE:The aim of this study was to implement a Dirichlet process mixture (DPM) model for automatic tumor edge identification on (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) images by optimizing the parameters on which the algorithm depends, to validate it experimentally, and to test its robus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947123

    authors: Giri MG,Cavedon C,Mazzarotto R,Ferdeghini M

    更新日期:2016-05-01 00:00:00

  • Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm.

    abstract:PURPOSE:Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4935199

    authors: Van Uytven E,Van Beek T,McCowan PM,Chytyk-Praznik K,Greer PB,McCurdy BM

    更新日期:2015-12-01 00:00:00

  • CUDA-based acceleration and BPN-assisted automation of bilateral filtering for brain MR image restoration.

    abstract:PURPOSE:Bilateral filters have been substantially exploited in numerous magnetic resonance (MR) image restoration applications for decades. Due to the deficiency of theoretical basis on the filter parameter setting, empirical manipulation with fixed values and noise variance-related adjustments has generally been emplo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12157

    authors: Chang HH,Chang YN

    更新日期:2017-04-01 00:00:00

  • Skeletal dosimetry in cone beam computed tomography.

    abstract::Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3147143

    authors: Walters BR,Ding GX,Kramer R,Kawrakow I

    更新日期:2009-07-01 00:00:00

  • Optimization of detector pixel size for stent visualization in x-ray fluoroscopy.

    abstract::Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as smal...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2169907

    authors: Jiang Y,Wilson DL

    更新日期:2006-03-01 00:00:00

  • Technical Note: Comparison of peripheral patient dose from MR-guided 60 Co therapy and 6 MV linear accelerator IGRT.

    abstract:PURPOSE:The use of X-ray imaging in radiation therapy can give a substantial dose to the patient. A Cobalt machine combined with an magnetic resonance imaging (MRI) was recently introduced to clinical work. One positive aspect of using non-ionizing imaging devices is the reduction of the patient exposure. The purpose o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12293

    authors: Hauri P,Hälg RA,Schneider U

    更新日期:2017-07-01 00:00:00

  • Primary dose in photon beams with lateral electron disequilibrium.

    abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596741

    authors: Nizin PS,Chang XS

    更新日期:1991-07-01 00:00:00