Skeletal dosimetry in cone beam computed tomography.

Abstract:

:Cone beam computed tomography (CBCT) is a relatively new patient imaging technique that has proved invaluable for treatment target verification and patient positioning during image-guided radiotherapy (IGRT). It has been shown that CBCT results in additional dose to bone that may amount to 10% of the prescribed dose. In this study, voxelized human phantoms, FAX06 (adult female) and MAX06 (adult male), are used together with phase-space data collected from a realistic model of a CBCT imager to calculate dose in the red bone marrow (RBM) and bone surface cells (BSCs), the two organs at risk within the bone spongiosa, during simulated head and neck, chest and pelvis CBCT scans. The FAX06/MAX06 phantoms model spongiosa based on micro-CT images, filling the relevant phantom voxels, which are 0.12 x 0.12 x 0.12 cm3, with 17 x 17 x 17 microm3 microvoxels to form a micromatrix of trabecular bone and bone marrow. FAX06/ MAX06 have already been implemented in an EGSnrc-based Monte Carlo code to simulate radiation transport in the phantoms; however, this study required significant modifications of the code to allow use of phase-space data from a simulated CBCT imager as a source and to allow scoring of total dose, RBM dose and BSC dose on a voxel-by-voxel basis. In simulated CBCT scans, the BSC dose is significantly greater than the dose to other organs at risk. For example, in a simulated head and neck scan, the average BSC dose is 25% higher than the average dose to eye lens (approximately 8.3 cGy), and 80% greater than the average dose to brain (5.7 cGy). Average dose to RBM, on the other hand, is typically only approximately 50% of the average BSC dose and less than the dose to other organs at risk (54% of the dose to eye lens and 76% of dose to brain in a head and neck scan). Thus, elevated dose in bone due to CBCT results in elevated BSC dose. This is potentially of concern when using CBCT in conjunction with radiotherapy treatment.

journal_name

Med Phys

journal_title

Medical physics

authors

Walters BR,Ding GX,Kramer R,Kawrakow I

doi

10.1118/1.3147143

subject

Has Abstract

pub_date

2009-07-01 00:00:00

pages

2915-22

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

36

pub_type

杂志文章
  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Patient doses and projection angle in cone beam CT.

    abstract:PURPOSE:To investigate how x-ray tube projection angle affects organ and effective doses to patients undergoing a CT examination on a cone beam scanner. METHODS:The authors investigated two cone beam CT systems that use a flat panel detector to capture the x-ray pattern transmitted through patients. One system had the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3397458

    authors: He W,Huda W,Magill D,Tavrides E,Yao H

    更新日期:2010-05-01 00:00:00

  • Evaluation of a deep learning-based computer-aided diagnosis system for distinguishing benign from malignant thyroid nodules in ultrasound images.

    abstract:PURPOSE:Computer-aided diagnosis (CAD) systems assist in solving subjective diagnosis problems that typically rely on personal experience. A CAD system has been developed to differentiate malignant thyroid nodules from benign thyroid nodules in ultrasound images based on deep learning methods. The diagnostic performanc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14301

    authors: Sun C,Zhang Y,Chang Q,Liu T,Zhang S,Wang X,Guo Q,Yao J,Sun W,Niu L

    更新日期:2020-09-01 00:00:00

  • Ideal-observer detectability in photon-counting differential phase-contrast imaging using a linear-systems approach.

    abstract:PURPOSE:To provide a cascaded-systems framework based on the noise-power spectrum (NPS), modulation transfer function (MTF), and noise-equivalent number of quanta (NEQ) for quantitative evaluation of differential phase-contrast imaging (Talbot interferometry) in relation to conventional absorption contrast under equal-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4739195

    authors: Fredenberg E,Danielsson M,Stayman JW,Siewerdsen JH,Aslund M

    更新日期:2012-09-01 00:00:00

  • WE-G-213CD-03: A Dual Complementary Verification Method for Dynamic Tumor Tracking on Vero SBRT.

    abstract:PURPOSE:to use complementary cine EPID and gimbals log file analysis for in-vivo tracking accuracy monitoring. METHODS:A clinical prototype of dynamic tracking (DT) was installed on the Vero SBRT system. This prototype version allowed tumor tracking by gimballed linac rotations using an internal-external correspondenc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4736204

    authors: Poels K,Depuydt T,Verellen D,De Ridder M

    更新日期:2012-06-01 00:00:00

  • Magnetic resonance imaging based digitally reconstructed radiographs, virtual simulation, and three-dimensional treatment planning for brain neoplasms.

    abstract::Currently, patients with brain neoplasms must undergo both computed tomography (CT) and magnetic resonance (MR) imaging to take advantage of CT's density information and MR's soft tissue imaging capabilities. A method has been developed that allows virtual simulation, digitally reconstructed radiographs (DRRs), and 3-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598382

    authors: Ramsey CR,Oliver AL

    更新日期:1998-10-01 00:00:00

  • Suitability of laser stimulated TLD arrays as patient dose monitors in high dose x-ray imaging.

    abstract::Skin entrance doses of patients undergoing interventional x-ray procedures are capable of causing skin damage and should be monitored routinely. Single TLD chips are not suitable because the location of maximum skin exposure cannot be predicted. Most photographic films are too sensitive at diagnostic x-ray energies fo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597973

    authors: Geise RA,Schueler BA,Lien W,Jones SC

    更新日期:1997-10-01 00:00:00

  • Direct cone-beam cardiac reconstruction algorithm with cardiac banding artifact correction.

    abstract::Multislice helical computed tomography (CT) is a promising noninvasive technique for coronary artery imaging. Various factors can cause inconsistencies in cardiac CT data, which can result in degraded image quality. These inconsistencies may be the result of the patient physiology (e.g., heart rate variations), the na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2163247

    authors: Taguchi K,Chiang BS,Hein IA

    更新日期:2006-02-01 00:00:00

  • Technical Note: Compact three-tesla magnetic resonance imager with high-performance gradients passes ACR image quality and acoustic noise tests.

    abstract:PURPOSE:A compact, three-tesla magnetic resonance imaging (MRI) system has been developed. It features a 37 cm patient aperture, allowing the use of commercial receiver coils. Its design allows simultaneously for gradient amplitudes of 85 millitesla per meter (mT/m) sustained and 700 tesla per meter per second (T/m/s) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941362

    authors: Weavers PT,Shu Y,Tao S,Huston J 3rd,Lee SK,Graziani D,Mathieu JB,Trzasko JD,Foo TK,Bernstein MA

    更新日期:2016-03-01 00:00:00

  • Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning.

    abstract:PURPOSE:In prostate radiotherapy, dose distribution may be calculated on CT images, while the MRI can be used to enhance soft tissue visualization. Therefore, a registration between MR and CT images could improve the overall treatment planning process, by improving visualization with a demonstrated interobserver deline...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12629

    authors: Hamdan I,Bert J,Rest CCL,Tasu JP,Boussion N,Valeri A,Dardenne G,Visvikis D

    更新日期:2017-12-01 00:00:00

  • Elements of microdosimetry.

    abstract::This is an introductory tutorial to the field of microdosimetry. Following a brief historical outline, we review the physics of experimental and theoretical microdosimetry and the application of microdosimetry to radiation biology within the so-called "site" approximation. Modern interpretations of microdosimetry that...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.596616

    authors: Rossi HH,Zaider M

    更新日期:1991-11-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Pelvic multi-organ segmentation on cone-beam CT for prostate adaptive radiotherapy.

    abstract:BACKGROUND AND PURPOSE:The purpose of this study is to develop a deep learning-based approach to simultaneously segment five pelvic organs including prostate, bladder, rectum, left and right femoral heads on cone-beam CT (CBCT), as required elements for prostate adaptive radiotherapy planning. MATERIALS AND METHODS:We...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14196

    authors: Fu Y,Lei Y,Wang T,Tian S,Patel P,Jani AB,Curran WJ,Liu T,Yang X

    更新日期:2020-08-01 00:00:00

  • Sci-Fri PM: Planning-04: Dose escalation study using anatomy-based aperture IMRT and SPECT perfusion images for lung cancer.

    abstract::In the case of non-small cell lung cancer, doses typically prescribed (60-66 Gy) are not sufficient to ensure a satisfactory tumor control probability. Dose escalation needs to be realized, but dose to organs at risk (OARs) must be kept under widely accepted clinical thresholds. Also, lung functionality is not homogen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965976

    authors: St-Hilaire J,Lavoie C,Beaulieu F,Dagnault A,Morin F,Gingras L,Tremblay D,Beaulieu L

    更新日期:2008-07-01 00:00:00

  • The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    abstract:PURPOSE:The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4901299

    authors: Schmitz T,Bassler N,Blaickner M,Ziegner M,Hsiao MC,Liu YH,Koivunoro H,Auterinen I,Serén T,Kotiluoto P,Palmans H,Sharpe P,Langguth P,Hampel G

    更新日期:2015-01-01 00:00:00

  • Dosimetry for radiocolloid therapy of cystic craniopharyngiomas.

    abstract::The dosimetry for radiocolloid therapy of cystic craniopharyngiomas is investigated. Analytical calculations based on the Loevinger and the Berger formulas for electrons and photons, respectively, are compared with Monte Carlo simulations. The role of the material of which the colloid introduced inside the craniophary...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1599653

    authors: Rojas EL,Al-Dweri FM,Lallena AM,Bodineau C,Galán P

    更新日期:2003-09-01 00:00:00

  • Improved motion-compensated image reconstruction for PET using sensitivity correction per respiratory gate and an approximate tube-of-response backprojector.

    abstract:PURPOSE:One limitation of positron emission tomography (PET) imaging of the torso is patient motion. Motion-compensated image reconstruction (MCIR) is one method employed to reduce the deleterious effects of motion. Existing MCIR algorithms use a single sensitivity correction term, which provides inexact normalization ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3611041

    authors: Dikaios N,Fryer TD

    更新日期:2011-09-01 00:00:00

  • Implementation of a three-dimensional compensation system based on computed tomography generated surface contours and tissue inhomogeneities.

    abstract::A computed tomography (CT) based system that compensates for patient surface contour and internal tissue inhomogeneity was implemented in our clinic. The compensators are fabricated with a mixture of tin granules and bee's wax. The tin/wax mixture was optimized for tin granule size and tin granule to wax ratio. The na...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597303

    authors: Jursinic PA,Podgorsak MB,Paliwal BR

    更新日期:1994-03-01 00:00:00

  • SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    abstract:PURPOSE:Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734998

    authors: Yi B,Yang X,Niu Y,Yu C

    更新日期:2012-06-01 00:00:00

  • SU-E-J-194: The Impact of Different Imaging Measures on Treatment Response Assessment of Bone Metastases.

    abstract:PURPOSE:Several treatment response metrics, such as RECIST and PERCIST, have been established for assessing individual solid tumors. However, metastatic prostate cancer poses a unique challenge to these metrics because bone lesions are often numerous and non-measureable. This study investigated the impact of using diff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735035

    authors: Morrison C,Liu G,Jeraj R

    更新日期:2012-06-01 00:00:00

  • Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

    abstract::A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436978

    authors: Liu T,Lizzi FL,Ketterling JA,Silverman RH,Kutcher GJ

    更新日期:2007-03-01 00:00:00

  • Monte Carlo based IMRT dose verification using MLC log files and R/V outputs.

    abstract::Conventional IMRT dose verification using film and ion chamber measurements is useful but limited with respect to the actual dose distribution received by the patient. The Monte Carlo simulation has been introduced as an independent dose verification tool for IMRT using the patient CT data and MLC leaf sequence files,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2208916

    authors: Luo W,Li J,Price RA Jr,Chen L,Yang J,Fan J,Chen Z,McNeeley S,Xu X,Ma CM

    更新日期:2006-07-01 00:00:00

  • Determination of exit skin dose for 192Ir intracavitary accelerated partial breast irradiation with thermoluminescent dosimeters.

    abstract:PURPOSE:Intracavitary accelerated partial breast irradiation (APBI) has become a popular treatment for early stage breast cancer in recent years due to its shortened course of treatment and simplified treatment planning compared to traditional external beam breast conservation therapy. However, the exit dose to the ski...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3429089

    authors: Raffi JA,Davis SD,Hammer CG,Micka JA,Kunugi KA,Musgrove JE,Winston JW Jr,Ricci-Ott TJ,DeWerd LA

    更新日期:2010-06-01 00:00:00

  • A fast 4D IMRT/VMAT planning method based on segment aperture morphing.

    abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12778

    authors: Klawikowski S,Tai A,Ates O,Ahunbay E,Li XA

    更新日期:2018-04-01 00:00:00

  • Semiautomated registration of pre- and intraoperative CT for image-guided percutaneous liver tumor ablation interventions.

    abstract:PURPOSE:In CT-guided liver tumor ablation interventions, registration of a preoperative contrast-enhanced CT image to the intraoperative CT image is hypothesized to improve guidance. This is a highly challenging registration task due to differences in patient poses and large deformations, and therefore high registratio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12332

    authors: Gunay G,Luu MH,Moelker A,van Walsum T,Klein S

    更新日期:2017-07-01 00:00:00

  • kQ factors for ionization chamber dosimetry in clinical proton beams.

    abstract::We discuss a formalism for clinical proton beam dosimetry based on the use of ionization chamber absorbed dose-to-water calibration and beam quality correction factors. A quantity kQ, the beam quality correction factor, is defined which corrects the absorbed dose-to-water calibration factor ND,w in a reference beam of...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597768

    authors: Vatnitsky SM,Siebers JV,Miller DW

    更新日期:1996-01-01 00:00:00

  • Average glandular dose coefficients for pendant-geometry breast CT using realistic breast phantoms.

    abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12477

    authors: Hernandez AM,Boone JM

    更新日期:2017-10-01 00:00:00

  • Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability.

    abstract:PURPOSE:This report describes upgrades and performance characterization of an experimental benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of metal probes such as gold nanoparticles (GNPs). Specifically, a high-power (~3 kW) indus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13138

    authors: Manohar N,Reynoso FJ,Cho SH

    更新日期:2018-10-01 00:00:00

  • First clinical implementation of real-time, real anatomy tracking and radiation beam control.

    abstract:PURPOSE:We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging-guided radiation therapy (MR-IGRT) system for real-time tracking and beam control. METHODS:The system utilizes real-time cine imaging ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13002

    authors: Green OL,Rankine LJ,Cai B,Curcuru A,Kashani R,Rodriguez V,Li HH,Parikh PJ,Robinson CG,Olsen JR,Mutic S,Goddu SM,Santanam L

    更新日期:2018-05-28 00:00:00

  • Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.

    abstract:PURPOSE:In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4966027

    authors: Esquinas PL,Tanguay J,Gonzalez M,Vuckovic M,Rodríguez-Rodríguez C,Häfeli UO,Celler A

    更新日期:2016-12-01 00:00:00