A feasible method for clinical delivery verification and dose reconstruction in tomotherapy.

Abstract:

:Delivery verification is the process in which the energy fluence delivered during a treatment is verified. This verified energy fluence can be used in conjunction with an image in the treatment position to reconstruct the full three-dimensional dose deposited. A method for delivery verification that utilizes a measured database of detector signal is described in this work. This database is a function of two parameters, radiological path-length and detector-to-phantom distance, both of which are computed from a CT image taken at the time of delivery. Such a database was generated and used to perform delivery verification and dose reconstruction. Two experiments were conducted: a simulated prostate delivery on an inhomogeneous abdominal phantom, and a nasopharyngeal delivery on a dog cadaver. For both cases, it was found that the verified fluence and dose results using the database approach agreed very well with those using previously developed and proven techniques. Delivery verification with a measured database and CT image at the time of treatment is an accurate procedure for tomotherapy. The database eliminates the need for any patient-specific, pre- or post-treatment measurements. Moreover, such an approach creates an opportunity for accurate, real-time delivery verification and dose reconstruction given fast image reconstruction and dose computation tools.

journal_name

Med Phys

journal_title

Medical physics

authors

Kapatoes JM,Olivera GH,Ruchala KJ,Smilowitz JB,Reckwerdt PJ,Mackie TR

doi

10.1118/1.1352579

subject

Has Abstract

pub_date

2001-04-01 00:00:00

pages

528-42

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

28

pub_type

杂志文章
  • Oxygen distribution in tumors: a qualitative analysis and modeling study providing a novel Monte Carlo approach.

    abstract:PURPOSE:To construct a Monte Carlo (MC)-based simulation model for analyzing the dependence of tumor oxygen distribution on different variables related to tumor vasculature [blood velocity, vessel-to-vessel proximity (vessel proximity), and inflowing oxygen partial pressure (pO2)]. METHODS:A voxel-based tissue model c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4892386

    authors: Lagerlöf JH,Kindblom J,Bernhardt P

    更新日期:2014-09-01 00:00:00

  • Thick phosphor screens for on-line portal imaging.

    abstract::Gd2O2S phosphor screens between 250 and 1000 mg/cm2 thick were evaluated for use in megavoltage imaging systems. The phosphor layers were placed on brass plates ranging from 1 to 5 mm thick, each with and without an optical back reflector (white paint). Light output and spatial resolution were measured at 6- and 23-MV...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597209

    authors: Wowk B,Shalev S

    更新日期:1994-08-01 00:00:00

  • Reverse mapping of normal tissue complication probabilities onto dose volume histogram space: the problem of randomness of the dose volume histogram sampling.

    abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198307

    authors: Markov K,Schinkel C,Stavreva N,Stavrev P,Weldon M,Fallone BG

    更新日期:2006-09-01 00:00:00

  • A regional convolution kernel algorithm for scatter correction in dual-energy images: comparison to single-kernel algorithms.

    abstract::Single kernel scatter correction algorithms are based on the model that the scatter field can be predicted by convolution of the primary intensity (Iprim) with a spatially invariant scatter point-spread function (PSF). Practical limitations (Iprim unknown) suggest the substitution of the total detected intensity (Idet...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597297

    authors: Kruger DG,Zink F,Peppler WW,Ergun DL,Mistretta CA

    更新日期:1994-02-01 00:00:00

  • Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz.

    abstract:PURPOSE:In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4897242

    authors: Ziegner M,Schmitz T,Khan R,Blaickner M,Palmans H,Sharpe P,Hampel G,Böck H

    更新日期:2014-11-01 00:00:00

  • Simplifying volumes-of-interest (VOIs) definition in quantitative SPECT: Beyond manual definition of 3D whole-organ VOIs.

    abstract:PURPOSE:We investigated the feasibility of using simpler methods than manual whole-organ volume-of-interest (VOI) definition to estimate the organ activity concentration in single photon emission computed tomography (SPECT) in cases where the activity in the organ can be assumed to be uniformly distributed on the scale...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12164

    authors: Vicente EM,Lodge MA,Rowe SP,Wahl RL,Frey EC

    更新日期:2017-05-01 00:00:00

  • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

    abstract::Subsecond single-slice, multi-slice or cone-beam spiral computed tomography (SSCT, MSCT, CBCT) offer great potential for improving heart imaging. Together with the newly developed phase-correlated cardiac reconstruction algorithms 180 degrees MCD and 180 degrees MCI [Med. Phys. 27, 1881-1902 (2000)] or related algorit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1487861

    authors: Kachelriess M,Sennst DA,Maxlmoser W,Kalender WA

    更新日期:2002-07-01 00:00:00

  • The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    abstract:PURPOSE:The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4901299

    authors: Schmitz T,Bassler N,Blaickner M,Ziegner M,Hsiao MC,Liu YH,Koivunoro H,Auterinen I,Serén T,Kotiluoto P,Palmans H,Sharpe P,Langguth P,Hampel G

    更新日期:2015-01-01 00:00:00

  • Mapping structural changes in breast tissue disease using x-ray scattering.

    abstract::Spread of invasive carcinoma throughout breast tissue is believed to occur at supramolecular levels, beyond the range of standard histopathology identification. Small angle x-ray scattering (SAXS) is capable of characterizing the structural properties of collagen and tissue found in the breast at the scale of tens to ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3147144

    authors: Sidhu S,Siu KK,Falzon G,Hart SA,Foxe JG,Lewis RA

    更新日期:2009-07-01 00:00:00

  • Penumbral measurements in water for high-energy x rays.

    abstract::Ionization chambers of varying inside diameter have been used to investigate the penumbral region of 60Co, 6-MV, and 31-MV x-ray beams. Measurements were made in water at varying depths up to 25 cm for a square field of side length 10 cm. The dependence of the penumbral widths on both the inside diameter of the ioniza...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595963

    authors: Dawson DJ,Schroeder NJ,Hoya JD

    更新日期:1986-01-01 00:00:00

  • Poster - Thur Eve - 23: Statistical analysis and verification of the percentage depth dose calculation based on the tissue maximum ratio in external beam radiotherapy.

    abstract::The aim of this study is to perform a statistical analysis to verify the calculated percentage depth dose (PDD) based on the tissue maximum ratio (TMR) with the PDD measurements taken in water. 6 and 15 MV photon beams produced by a Varian linear 2100 C/D accelerator were used. PDDs and TMRs were measured at various d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740131

    authors: Isa M,Iqbal K,Afzal M,Buzdar S,Chow J

    更新日期:2012-07-01 00:00:00

  • Reconstruction of diagnostic x-ray spectra by numerical analysis of transmission data.

    abstract::Numerical reconstruction of x-ray spectra from narrow-beam transmission data was tested with published spectra in the range from 45 to 100 kVp. Transmission curves were calculated from the spectra to simulate measured data. Spectra were reconstructed from these transmission curves with use of an iterative numerical an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595834

    authors: Huang PH,Chen TS,Kase KR

    更新日期:1986-09-01 00:00:00

  • Technical Note: Characterization and correction of gradient nonlinearity induced distortion on a 1.0 T open bore MR-SIM.

    abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930245

    authors: Price RG,Kadbi M,Kim J,Balter J,Chetty IJ,Glide-Hurst CK

    更新日期:2015-10-01 00:00:00

  • Quantitative CT of lung nodules: dependence of calibration on patient body size, anatomic region, and calibration nodule size for single- and dual-energy techniques.

    abstract::Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more ca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148536

    authors: Goodsitt MM,Chan HP,Way TW,Schipper MJ,Larson SC,Christodoulou EG

    更新日期:2009-07-01 00:00:00

  • Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

    abstract::The anti-scatter grid has been widely used to reject scatter and increase the perceptibility of a low-contrast object in chest radiography; however, it also attenuated the primary x-rays, resulting in a substantial loss of information and an increased relative noise level in heavily attenuated regions. A more dose eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2739805

    authors: Liu X,Shaw CC

    更新日期:2007-07-01 00:00:00

  • Application of solid state detectors for dosimetry of therapeutic proton beams.

    abstract::A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597608

    authors: Vatnitsky S,Miller D,Siebers J,Moyers M

    更新日期:1995-04-01 00:00:00

  • Actively triggered 4d cone-beam CT acquisition.

    abstract:PURPOSE:4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this "after-the-fact" binning approach, however, projections are uneve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817479

    authors: Fast MF,Wisotzky E,Oelfke U,Nill S

    更新日期:2013-09-01 00:00:00

  • Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning.

    abstract::The purpose of this study is to perform a clinical evaluation of the first commercial (MDS Nordion, now Nucletron) treatment planning system for electron beams incorporating Monte Carlo dose calculation module. This software implements Kawrakow's VMC++ voxel-based Monte Carlo calculation algorithm. The accuracy of the...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1633105

    authors: Cygler JE,Daskalov GM,Chan GH,Ding GX

    更新日期:2004-01-01 00:00:00

  • Beam modeling and verification of a photon beam multisource model.

    abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1898485

    authors: Ahnesjö A,Weber L,Murman A,Saxner M,Thorslund I,Traneus E

    更新日期:2005-06-01 00:00:00

  • Anthropomorphic 1H MRS head phantom.

    abstract::An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598306

    authors: Rice JR,Milbrandt RH,Madsen EL,Frank GR,Boote EJ,Blechinger JC

    更新日期:1998-07-01 00:00:00

  • Monte Carlo study of ionization chamber magnetic field correction factors as a function of angle and beam quality.

    abstract:PURPOSE:To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine optimal measurement orientations, calculate beam quality conversion factors for 32 cylindrical and three parallel-plate (PP) ion chambers, evaluate the beam quality and angular dependence of these factors, and examine the magnetic f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12716

    authors: Malkov VN,Rogers DWO

    更新日期:2018-02-01 00:00:00

  • Localization of cochlear implant electrodes in radiographs.

    abstract::Multielectrode cochlear implantation is the most effective treatment for profound sensorineural hearing loss. In vivo three-dimensional 3-D localization of cochlear implant electrodes is important for modeling of the electrical field in the cochlea, design of electrode arrays, and may improve speech processor programm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598940

    authors: Yang S,Wang G,Skinner MW,Rubinstein JT,Vannier MW

    更新日期:2000-04-01 00:00:00

  • Differentiation between diamagnetic and paramagnetic cerebral lesions based on magnetic susceptibility mapping.

    abstract:PURPOSE:Identification of calcifications and hemorrhages is essential for the etiological diagnosis of cerebral lesions. The purpose of this work was to develop a robust method for characterization of para- and diamagnetic intracerebral lesions based on clinical gradient-echo magnetic resonance phase data acquired at 1...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3481505

    authors: Schweser F,Deistung A,Lehr BW,Reichenbach JR

    更新日期:2010-10-01 00:00:00

  • Oblique incidence for broad monoenergetic proton beams.

    abstract:PURPOSE:The depth dose of a monoenergetic broad parallel proton beam has been modeled in a number of ways, but evidently not yet for oblique incidence. The purpose of this investigation is to find an accurate analytic formula for this case, which can then be used to model the depth dose of a broad beam with an initial ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3495969

    authors: Jette D,Yuan J,Chen W

    更新日期:2010-11-01 00:00:00

  • TU-D-213AB-01: How You Can Be the Speaker and Communicator Everyone Wants You to Be.

    abstract::Effectiveness of an oral presentation depends on the ability of the speaker to communicate with the audience. An important part of this communication is focusing on two to five key points and emphasizing those points during the presentation. Every aspect of the presentation should be purposeful and directed at facilit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735944

    authors: Collins J,Aydogan B

    更新日期:2012-06-01 00:00:00

  • Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability.

    abstract:PURPOSE:This report describes upgrades and performance characterization of an experimental benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system capable of determining the spatial distribution and concentration of metal probes such as gold nanoparticles (GNPs). Specifically, a high-power (~3 kW) indus...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13138

    authors: Manohar N,Reynoso FJ,Cho SH

    更新日期:2018-10-01 00:00:00

  • General strategy for the protection of organs at risk in IMRT therapy of a moving body.

    abstract::We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it po...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3132305

    authors: Abolfath RM,Papiez L

    更新日期:2009-07-01 00:00:00

  • The use of a priori information in the detection of mammographic microcalcifications to improve their classification.

    abstract::In this work, we present a calcification-detection scheme that automatically localizes calcifications in a previously detected cluster in order to generate the input for a cluster-classification scheme developed in the past. The calcification-detection scheme makes use of three pieces of a priori information: the loca...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1559884

    authors: Salfity MF,Nishikawa RM,Jiang Y,Papaioannou J

    更新日期:2003-05-01 00:00:00

  • SU-E-T-590: Procedure for Verification and Inter-Comparison of IMRT Beam Models.

    abstract:PURPOSE:The implementation of an accurate beam model is an integral part of the commissioning of any planning system. This process is especially challenging in the case of IMRT beam models owing to the complexity of small field sizes and MLC leaf-end and tongue-and-groove effects. The question of how to judge the quali...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735679

    authors: Veltchev I,Fourkal E,Price R,Ma C

    更新日期:2012-06-01 00:00:00

  • The potential role of positron emission mammography for detection of breast cancer. A phantom study.

    abstract::Positron emission mammography (PEM) is a new, specialized imaging modality utilizing PET radiopharmaceuticals to detect breast cancer. The capabilities and limitations of PEM in detecting breast tumors were investigated with a series of phantom experiments. The PEM imager was mounted on a standard Lorad biopsy table (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1287439

    authors: Raylman RR,Majewski S,Wojcik R,Weisenberger AG,Kross B,Popov V,Bishop HA

    更新日期:2000-08-01 00:00:00