Actively triggered 4d cone-beam CT acquisition.

Abstract:

PURPOSE:4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this "after-the-fact" binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor. METHODS:The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective "Faraday" shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories. RESULTS:With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145 projections were acquired per respiratory phase resulting in a dose of ∼1.7-2.6 mGy per respiratory phase. Further dose savings and decreases in the scanning time are possible by acquiring only a subset of all respiratory phases, for example, peak-exhale and peak-inhale only scans. CONCLUSIONS:This study is the first experimental demonstration of a new 4d CBCT acquisition paradigm in which imaging dose is efficiently utilized by actively triggering only those projections that are desired for the reconstruction process.

journal_name

Med Phys

journal_title

Medical physics

authors

Fast MF,Wisotzky E,Oelfke U,Nill S

doi

10.1118/1.4817479

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

091909

issue

9

eissn

0094-2405

issn

2473-4209

journal_volume

40

pub_type

杂志文章
  • Classification of breast lesions using segmented quantitative ultrasound maps of homodyned K distribution parameters.

    abstract:PURPOSE:Statistical modeling of an ultrasound backscattered echo envelope is used for tissue characterization. However, in the presence of complex structures within the analyzed area, estimation of parameters is disturbed and unreliable, e.g., in the case of breast tumor classification. In order to improve the differen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4962928

    authors: Byra M,Nowicki A,Wróblewska-Piotrzkowska H,Dobruch-Sobczak K

    更新日期:2016-10-01 00:00:00

  • Improved motion-compensated image reconstruction for PET using sensitivity correction per respiratory gate and an approximate tube-of-response backprojector.

    abstract:PURPOSE:One limitation of positron emission tomography (PET) imaging of the torso is patient motion. Motion-compensated image reconstruction (MCIR) is one method employed to reduce the deleterious effects of motion. Existing MCIR algorithms use a single sensitivity correction term, which provides inexact normalization ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3611041

    authors: Dikaios N,Fryer TD

    更新日期:2011-09-01 00:00:00

  • Study of the secondary neutral radiation in proton therapy: toward an indirect in vivo dosimetry.

    abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4765049

    authors: Carnicer A,Letellier V,Rucka G,Angellier G,Sauerwein W,Herault J

    更新日期:2012-12-01 00:00:00

  • SU-E-J-17: Evaluation of Metal Artifact Reduction in MVCTs Using a Model Based Image Reconstruction Method.

    abstract:PURPOSE:To evaluate the performance of a model based image reconstruction in reducing metal artifacts in MVCT systems, and to compare with filtered-back projection (FBP) technique. METHODS:Iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with pair/triplet production process and the energy d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734850

    authors: Paudel M,MacKenzie M,Fallone B,Rathee S

    更新日期:2012-06-01 00:00:00

  • Voxel clustering for quantifying PET-based treatment response assessment.

    abstract:PURPOSE:Imaging biomarkers are crucial in managing treatment options for cancer patients. They are extremely powerful tools since they allow personalized treatment assessment early during therapy by using repeated imaging to detect and quantify tumor response. Currently, treatment response assessment from consecutive i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4764900

    authors: Schreibmann E,Waller AF,Crocker I,Curran W,Fox T

    更新日期:2013-01-01 00:00:00

  • SU-E-T-126: Non-Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High-Energy Photons.

    abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735184

    authors: Chofor N,Poppe B,Harder D

    更新日期:2012-06-01 00:00:00

  • Accuracy evaluation of a six-degree-of-freedom couch using cone beam CT and IsoCal phantom with an in-house algorithm.

    abstract:PURPOSE:The accuracy of a six degree of freedom (6DoF) couch was evaluated using a novel method. METHODS:Cone beam CT (CBCT) images of a 3D phantom (IsoCal) were acquired with different, known combinations of couch pitch and roll angles. Pitch and roll angles between the maximum allowable values of 357 and 3 degrees w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12342

    authors: Zhang Q,Driewer J,Wang S,Li S,Zhu X,Zheng D,Cao Y,Zhang J,Jamshidi A,Cox BW,Knisely JPS,Potters L,Klein EE

    更新日期:2017-08-01 00:00:00

  • X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays.

    abstract::We have measured the linearity, spatial resolution (MTF), noise (NPS), and signal-to-noise characteristics (DQE) of an electronic portal imaging device (EPID) based on an amorphous silicon flat-panel array. The array has a 128 x 128-pixel matrix and each pixel is 0.75 x 0.75 mm2 in dimension so the array covers an are...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598252

    authors: Munro P,Bouius DC

    更新日期:1998-05-01 00:00:00

  • Characteristics of metal-plate/film detectors at therapy energies. II. Detective quantum efficiency.

    abstract::Noise power spectrum (NPS) and detective quantum efficiency (DQE) for metal-plate/film portal detectors are reported for the Co-60 and Linac 10 MV spectra. The detectors consist of a double-emulsion portal film secured between plates of aluminum, copper, brass, or lead. The NPS was found to be independent of the detec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598437

    authors: Falco T,Fallone BG

    更新日期:1998-12-01 00:00:00

  • An EGS4 Monte Carlo examination of the response of a PTW-diamond radiation detector in megavoltage electron beams.

    abstract::The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irrad...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598593

    authors: Mobit PN,Sandison GA

    更新日期:1999-05-01 00:00:00

  • Constrained reconstruction: a superresolution, optimal signal-to-noise alternative to the Fourier transform in magnetic resonance imaging.

    abstract::Many problems in physics involve imaging objects with high spatial frequency content in a limited amount of time. The limitation of available experimental data leads to the infamous problem of diffraction limited data which manifests itself by causing ringing in the image. This ringing is due to the interference pheno...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596427

    authors: Haacke EM,Liang ZP,Izen SH

    更新日期:1989-05-01 00:00:00

  • Thermodynamic considerations of acrylic cement implant at the site of giant cell tumors of the bone.

    abstract::A discussion of the thermodynamic aspects of a relatively new treatment method for giant cell tumors of the bone is presented in this paper. The advantages of implanting methylmethacrylate acrylic bone cement into a curetted tumor site are briefly discussed and placed in perspective relative to more prevalent surgical...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595902

    authors: Krishnan EC,Nelson C,Neff JR

    更新日期:1986-03-01 00:00:00

  • Dosimetric characterization of radionuclides for systemic tumor therapy: influence of particle range, photon emission, and subcellular distribution.

    abstract::Various radionuclides have been proposed for systemic tumor therapy. However, in most dosimetric analysis of proposed radionuclides the charged particles are taken into consideration while the potential photons are ignored. The photons will cause undesirable irradiation of normal tissue, and increase the probability o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2229428

    authors: Uusijärvi H,Bernhardt P,Ericsson T,Forssell-Aronsson E

    更新日期:2006-09-01 00:00:00

  • Effect of respiratory motion on the delivery of breast radiotherapy using SMLC intensity modulation.

    abstract::This study evaluates the effects of respiratory motion on breast radiotherapy delivered using segmented multileaf collimator (SMLC) intensity modulation. An anthropomorphic breast phantom was constructed of polystyrene plates between which radiographic films were inserted. The phantom was mounted on a moving platform ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2405323

    authors: Liu Q,McDermott P,Burmeister J

    更新日期:2007-01-01 00:00:00

  • Pulmonary embolism in pregnant patients: Assessing organ dose to pregnant phantom and its fetus during lung imaging.

    abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12558

    authors: Rafat Motavalli L,Hoseinian Azghadi E,Miri Hakimabad H,Akhlaghi P

    更新日期:2017-11-01 00:00:00

  • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.

    abstract::Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2746492

    authors: Brisse HJ,Madec L,Gaboriaud G,Lemoine T,Savignoni A,Neuenschwander S,Aubert B,Rosenwald JC

    更新日期:2007-07-01 00:00:00

  • Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging.

    abstract:PURPOSE:Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow qua...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4943565

    authors: Hunter CR,Klein R,Beanlands RS,deKemp RA

    更新日期:2016-04-01 00:00:00

  • Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors.

    abstract:PURPOSE:Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3312435

    authors: Le Huy Q,Ducote JL,Molloi S

    更新日期:2010-03-01 00:00:00

  • A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.

    abstract:PURPOSE:A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12459

    authors: Ma Y,Vijande J,Ballester F,Tedgren ÅC,Granero D,Haworth A,Mourtada F,Fonseca GP,Zourari K,Papagiannis P,Rivard MJ,Siebert FA,Sloboda RS,Smith R,Chamberland MJP,Thomson RM,Verhaegen F,Beaulieu L

    更新日期:2017-11-01 00:00:00

  • Photon and electron response of silicon-diode neutron detectors.

    abstract::The photon response of silicon-diode neutron detectors is analyzed theoretically and measured in the 15-25-MeV region. The main mechanism for producing a response in the diode is shown to be the displacement of silicon atoms by scattering of electrons. If the photon source is an electron accelerator target, the respon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594403

    authors: McCall RC,Jenkins TM,Oliver GD Jr

    更新日期:1978-01-01 00:00:00

  • Analytical probabilistic modeling of dose-volume histograms.

    abstract:PURPOSE:Radiotherapy, especially with charged particles, is sensitive to executional and preparational uncertainties that propagate to uncertainty in dose and plan quality indicators, for example, dose-volume histograms (DVHs). Current approaches to quantify and mitigate such uncertainties rely on explicitly computed e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14414

    authors: Wahl N,Hennig P,Wieser HP,Bangert M

    更新日期:2020-10-01 00:00:00

  • Dependence of virtual wedge factor on dose calibration and monitor units.

    abstract::One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344204

    authors: Zhu XR,Gillin MT,Ehlers K,Lopez F,Grimm DF,Rownd JJ,Steinberg TH

    更新日期:2001-02-01 00:00:00

  • The alanine detector in BNCT dosimetry: dose response in thermal and epithermal neutron fields.

    abstract:PURPOSE:The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4901299

    authors: Schmitz T,Bassler N,Blaickner M,Ziegner M,Hsiao MC,Liu YH,Koivunoro H,Auterinen I,Serén T,Kotiluoto P,Palmans H,Sharpe P,Langguth P,Hampel G

    更新日期:2015-01-01 00:00:00

  • A method to compare supra-pubic ultrasound and CT images of the prostate: technique and early clinical results.

    abstract::We describe a unique method that allows the comparison of spatially registered ultrasound (SRUS) images and computed tomography-derived contours (CTDCs) that were acquired with a minimal time lapse. As such, we have a tool that will provide validation of the spatial accuracy of the US system and that will allow compar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1644515

    authors: Molloy JA,Srivastava S,Schneider BF

    更新日期:2004-03-01 00:00:00

  • Trajectory analysis for field free line magnetic particle imaging.

    abstract:PURPOSE:Magnetic particle imaging (MPI) is a relatively new method to image the spatial distribution of magnetic nanoparticle (MNP) tracers administered to the body with high spatial and temporal resolution using an inhomogeneous magnetic field. The spatial information of the MNP's is encoded using a field free point (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13411

    authors: Top CB,Güngör A,Ilbey S,Güven HE

    更新日期:2019-04-01 00:00:00

  • An approximate short scan helical FDK cone beam algorithm based on nutating curved surfaces satisfying the Tuy's condition.

    abstract::Traditionally, short scan helical FDK algorithms have been implemented based on horizontal transaxial slices. However, not every point on the horizontal transaxial slice satisfies Tuy's condition for the corresponding (pi+fan angle) segment of helix, which means that some points on the horizontal slices are incomplete...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1916077

    authors: Hu J,Tam K,Qi J

    更新日期:2005-06-01 00:00:00

  • SU-D-211-06: The Effect of Motion in RapidArc Lung SBRT Delivery.

    abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734660

    authors: Zou J,Yin L,Shen J,Corradetti M,Kirk M,Rengan R,Teo BK

    更新日期:2012-06-01 00:00:00

  • Model-based geometric calibration for medical x-ray systems.

    abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4931964

    authors: van der Maas R,de Jager B,Steinbuch M,Dries J

    更新日期:2015-11-01 00:00:00

  • Octavius 4D characterization for flattened and flattening filter free rotational deliveries.

    abstract:PURPOSE:In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans. METHODS:The response o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4817482

    authors: McGarry CK,O'Connell BF,Grattan MW,Agnew CE,Irvine DM,Hounsell AR

    更新日期:2013-09-01 00:00:00

  • Sci-Sat AM(1): Imaging-01: Tumour and normal tissue T2 and ADC distributions for a mouse model at 9.4T.

    abstract::Magnetic resonance (MR) measurements of relaxation times and diffusion coefficient in tissue have been demonstrated to be sensitive to biological changes induced by radiation therapy. We are currently using mouse models of human glioblastoma multiforme (GBM) to study tumour response to ionizing radiation by MRI at 9.4...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965985

    authors: Larocque M,Syme A,Fallone BG

    更新日期:2008-07-01 00:00:00