Penumbral measurements in water for high-energy x rays.

Abstract:

:Ionization chambers of varying inside diameter have been used to investigate the penumbral region of 60Co, 6-MV, and 31-MV x-ray beams. Measurements were made in water at varying depths up to 25 cm for a square field of side length 10 cm. The dependence of the penumbral widths on both the inside diameter of the ionization chamber and the depth in water is established along with the asymmetry of the penumbral distributions about the 50% level. A standard correction is indicated to eliminate the dependence of the measured penumbral widths on the inside diameter of the ionization chamber.

journal_name

Med Phys

journal_title

Medical physics

authors

Dawson DJ,Schroeder NJ,Hoya JD

doi

10.1118/1.595963

subject

Has Abstract

pub_date

1986-01-01 00:00:00

pages

101-4

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

13

pub_type

杂志文章
  • SU-E-J-170: Clinical Evaluation of Positioning Accuracy of Two Immobilization Devices for Stereotactic Body Radiotherapy Using Cone Beam CT.

    abstract:PURPOSE:To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS:Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta ster...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735009

    authors: Cao M,Cao N,Cardenes H,Fakiris A,Desrosiers C,Das I

    更新日期:2012-06-01 00:00:00

  • Scattered radiation in chest radiography.

    abstract::Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595027

    authors: Niklason LT,Sorenson JA,Nelson JA

    更新日期:1981-09-01 00:00:00

  • Measurements of the neutron yields from 7Li(p,n)7Be reaction (thick target) with incident energies from 1.885 to 2.0 MeV.

    abstract::Accelerator-based neutron source have been considered to be practical for boron neutron capture therapy (BNCT). Based on experience with a parameters of the Brookhaven National Laboratory BMRR reactor neutron source, which has been used in treatment experiments, the future accelerator-based neutron source for BNCT sho...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598299

    authors: Yu W,Yue G,Han X,Chen J,Tian B

    更新日期:1998-07-01 00:00:00

  • Registration of clinical volumes to beams-eye-view images for real-time tracking.

    abstract:PURPOSE:The authors combine the registration of 2D beam's eye view (BEV) images and 3D planning computed tomography (CT) images, with relative, markerless tumor tracking to provide automatic absolute tracking of physician defined volumes such as the gross tumor volume (GTV). METHODS:During treatment of lung SBRT cases...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4900603

    authors: Bryant JH,Rottmann J,Lewis JH,Mishra P,Keall PJ,Berbeco RI

    更新日期:2014-12-01 00:00:00

  • A four-alternative forced choice (4AFC) methodology for evaluating microcalcification detection in clinical full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) systems using an inkjet-printed anthropomorphic phantom.

    abstract:PURPOSE:The advent of three-dimensional breast imaging systems such as digital breast tomosynthesis (DBT) has great promise for improving the detection and diagnosis of breast cancer. With these new technologies comes an essential need for testing methods to assess the resultant image quality. Although randomized clini...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13629

    authors: Ikejimba LC,Salad J,Graff CG,Ghammraoui B,Cheng WC,Lo JY,Glick SJ

    更新日期:2019-09-01 00:00:00

  • Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    abstract:PURPOSE:To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. METHODS:The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4722967

    authors: Catuzzo P,Zenone F,Aimonetto S,Peruzzo A,Casanova Borca V,Pasquino M,Franco P,La Porta MR,Ricardi U,Tofani S

    更新日期:2012-07-01 00:00:00

  • ARPM-net: A novel CNN-based adversarial method with Markov random field enhancement for prostate and organs at risk segmentation in pelvic CT images.

    abstract:PURPOSE:The research is to develop a novel CNN-based adversarial deep learning method to improve and expedite the multi-organ semantic segmentation of CT images and to generate accurate contours on pelvic CT images. METHODS:Planning CT and structure datasets for 120 patients with intact prostate cancer were retrospect...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14580

    authors: Zhang Z,Zhao T,Gay H,Zhang W,Sun B

    更新日期:2020-11-05 00:00:00

  • Technical and dosimetric realization of in vivo x-ray microbeam irradiations at the Munich Compact Light Source.

    abstract:PURPOSE:X-ray microbeam radiation therapy is a preclinical concept for tumor treatment promising tissue sparing and enhanced tumor control. With its spatially separated, periodic micrometer-sized pattern, this method requires a high dose rate and a collimated beam typically available at large synchrotron radiation faci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14433

    authors: Burger K,Urban T,Dombrowsky AC,Dierolf M,Günther B,Bartzsch S,Achterhold K,Combs SE,Schmid TE,Wilkens JJ,Pfeiffer F

    更新日期:2020-10-01 00:00:00

  • Dose in the buildup region outside the primary beam.

    abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595508

    authors: Horton JL

    更新日期:1984-05-01 00:00:00

  • Noise power spectra of images from digital mammography detectors.

    abstract::Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. We begin with a brief review of the fundamentals of NPS theory and measurement, derive explicit expressions for calculation of the one- and two-dimensional (1D and 2D) NPS, and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598623

    authors: Williams MB,Mangiafico PA,Simoni PU

    更新日期:1999-07-01 00:00:00

  • A compensative model for the angle-dependence of motion estimates in noninvasive vascular elastography.

    abstract:PURPOSE:Atherosclerosis of peripheral cerebral arteries can lead to stroke either by stenosis formation or plaque rupture. This pathology is initiated by the alteration of arterial wall mechanical properties shown to be assessable by ultrasound elastography. Recently, noninvasive vascular elastography (NIVE) was introd...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3539701

    authors: Mercure E,Deprez JF,Fromageau J,Basset O,Soulez G,Cloutier G,Maurice RL

    更新日期:2011-02-01 00:00:00

  • The use of PET images for radiotherapy treatment planning: an error analysis using radiobiological endpoints.

    abstract:PURPOSE:There is significant current interest in the use of biological image guidance in radiotherapy planning. In lung-cancer treatment, tumor motion due to respiration is known to be a limitation. This is particularly true in PET, where image data are collected over a number of minutes. An in-house-developed 4D PET a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3276776

    authors: Perrin R,Evans PM,Webb S,Partridge M

    更新日期:2010-02-01 00:00:00

  • Feasibility study of patient-specific energy verification using a multilayer acrylic-disk radiation sensor.

    abstract:PURPOSE:Obtaining an integral depth-dose (IDD) curve using a recently developed acrylic-disk radiation sensor (ADRS) is time-consuming because its single structure requires point-by-point measurements in a water phantom. The goal of this study was to verify the ability of a newly designed multilayer ADRS, composed of 2...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14326

    authors: Son J,Shin D,Kim T,Park S,Rah JE

    更新日期:2020-09-01 00:00:00

  • Beam modeling and verification of a photon beam multisource model.

    abstract::Dose calculations for treatment planning of photon beam radiotherapy require a model of the beam to drive the dose calculation models. The beam shaping process involves scattering and filtering that yield radiation components which vary with collimator settings. The necessity to model these components has motivated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1898485

    authors: Ahnesjö A,Weber L,Murman A,Saxner M,Thorslund I,Traneus E

    更新日期:2005-06-01 00:00:00

  • Dosimetric effects of contrast media for catheter-based intravascular brachytherapy.

    abstract::The purpose of this work is to calculate the dose perturbations due to the presence of iodine contrast media in catheter-based intravascular brachytherapy (IVBT). The EGSnrc Monte Carlo system was used to perform the calculation for the two most commonly used beta and gamma sources (90Sr and 192Ir as well as for a var...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1367279

    authors: Li XA

    更新日期:2001-05-01 00:00:00

  • Surface dose rate calibration of Sr-90 plane ophthalmic applicators.

    abstract::Calibration of an imported strontium-90 ophthalmic applicator at the U.S. National Bureau of Standards (now the National Institute of Standards and Technology) has disclose a significant discrepancy in dose rate calibration (32%-35%) with that quoted by the manufacturer. The University of Wisconsin has investigated th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596702

    authors: Goetsch SJ,Sunderland KS

    更新日期:1991-03-01 00:00:00

  • Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry.

    abstract:PURPOSE:To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. METHODS:Twenty volumetric images of patient breasts were acquired with a dedicated...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4737025

    authors: Sechopoulos I,Bliznakova K,Qin X,Fei B,Feng SS

    更新日期:2012-08-01 00:00:00

  • A delivery quality assurance tool based on the actual leaf open times in tomotherapy.

    abstract:PURPOSE:To validate a delivery quality assurance (DQA) protocol for tomotherapy based on the measurement of the leaf open times (LOTs). In addition, to show the correlation between the mean relative LOT discrepancy and the dose deviation in the planning target volume (PTV). MATERIALS AND METHODS:We used a LOT measurem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14348

    authors: Schopfer M,Bochud FO,Bourhis J,Moeckli R

    更新日期:2020-09-01 00:00:00

  • Cascaded systems analysis of shift-variant image quality in slit-scanning breast tomosynthesis.

    abstract:PURPOSE:Digital breast tomosynthesis (DBT) is becoming an important part of breast cancer screening and diagnosis. Compared to two-dimensional mammography, tomosynthesis introduces limited three-dimensional (3D) resolution, but maintains high in-plane resolution, low dose, and allows for similar clinical protocols. The...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13116

    authors: Berggren K,Cederström B,Lundqvist M,Fredenberg E

    更新日期:2018-10-01 00:00:00

  • Normalization (division) versus subtraction of digitized images.

    abstract::The propagation of noise in digitized images arrived at by algebraic manipulation of two images has been investigated. The algebraic manipulations investigated were logarithmic subtraction, linear subtraction, and division of the two images. The two images were identical except for the presence of a contrast-adding co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595289

    authors: Baily NA,Rimkus D,Nalcioglu O

    更新日期:1983-01-01 00:00:00

  • Treatment planning algorithm corrections accounting for random setup uncertainties in fractionated stereotactic radiotherapy.

    abstract::A number of relocatable head fixation systems have become commercially available or developed in-house to perform fractionated stereotactic radiotherapy (SRT) treatment. The uncertainty usually quoted for the target repositioning in SRT is over 2 mm, more than twice that of stereotactic radiosurgery (SRS) systems. Thi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598930

    authors: Zavgorodni SF

    更新日期:2000-04-01 00:00:00

  • Gadolinium neutron capture therapy for brain tumors: a computer study.

    abstract::A Monte Carlo computer study of the total dose distribution from neutrons and prompt gamma emissions (but excluding the contribution from conversion and Auger electrons) for gadolinium neutron capture therapy of brain tumors has been carried out in order to test the theoretic feasibility of this modality using commerc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596761

    authors: Masiakowski JT,Horton JL,Peters LJ

    更新日期:1992-09-01 00:00:00

  • Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

    abstract:PURPOSE:Tomosynthesis is a promising modality for breast imaging. The appearance of the tomosynthesis reconstructed image is greatly affected by the choice of acquisition and reconstruction parameters. The purpose of this study was to investigate the limitations of tomosynthesis breast imaging due to scan parameters an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3357288

    authors: Reiser I,Nishikawa RM

    更新日期:2010-04-01 00:00:00

  • Integration of microwave tomography with magnetic resonance for improved breast imaging.

    abstract:PURPOSE:Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and elec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4820361

    authors: Meaney PM,Golnabi AH,Epstein NR,Geimer SD,Fanning MW,Weaver JB,Paulsen KD

    更新日期:2013-10-01 00:00:00

  • Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    abstract:PURPOSE:High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process contr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901520

    authors: Létourneau D,Wang A,Amin MN,Pearce J,McNiven A,Keller H,Norrlinger B,Jaffray DA

    更新日期:2014-12-01 00:00:00

  • Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy.

    abstract::In order to investigate the relationship between diagnostic accuracy and radiographic image quality, we have developed a dual-film cassette which produces two radiographs simultaneously with a single exposure. One of these radiographs is of standard quality; the second is of lower quality because of degraded spatial r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595546

    authors: Higashida Y,Doi K,Lehr JL,MacMahon H

    更新日期:1984-09-01 00:00:00

  • Dependence of virtual wedge factor on dose calibration and monitor units.

    abstract::One of the important features of the Siemens Virtual Wedge (VW) is that the VW factor (VWF) is approximately equal to unity for all beams with a total deviation for a given wedge no greater than 0.05, as specified by Siemens. In this note we report the observed dependence of VWF on dose calibration (cGy/MU), monitor u...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1344204

    authors: Zhu XR,Gillin MT,Ehlers K,Lopez F,Grimm DF,Rownd JJ,Steinberg TH

    更新日期:2001-02-01 00:00:00

  • Reduction of ring artifacts in CBCT: detection and correction of pixel gain variations in flat panel detectors.

    abstract:PURPOSE:In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accou...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4893278

    authors: Altunbas C,Lai CJ,Zhong Y,Shaw CC

    更新日期:2014-09-01 00:00:00

  • Power deposition in whole-body NMR imaging.

    abstract::The surface radio frequency (rf) power absorption in human head and torso nuclear magnetic resonance (NMR) imaging experiments is estimated. The results are expressed as a function of the NMR frequency, the rf pulse length, and the pulse duty cycle, which are varied over six orders of magnitude for general applicabili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595000

    authors: Bottomley PA,Edelstein WA

    更新日期:1981-07-01 00:00:00

  • Sci-Thur PM: YIS - 08: The effect of copper conversion plates on low-Z target image quality.

    abstract::Current generation electronic portal imaging devices (EPID) contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When using these EPIDs for low-Z target imaging, the conversion plate largely attenuates the large populations of diagnostic energy photons, there...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4740105

    authors: Parsons D,Robar JL

    更新日期:2012-07-01 00:00:00