Abstract:
:The propagation of noise in digitized images arrived at by algebraic manipulation of two images has been investigated. The algebraic manipulations investigated were logarithmic subtraction, linear subtraction, and division of the two images. The two images were identical except for the presence of a contrast-adding component in one of them. The two extreme cases of video-fluoroscope system behavior, gray level proportional to incident photon flux and gray level proportional to the product of thickness and linear attenuation coefficient, were investigated. The ratio of signal to noise was calculated for each of these cases and a figure of merit established for the ratio of signal to noise of the division process versus each of the subtraction processes for each of the two fluoroscopic system behaviors. In all cases, this figure of merit is greater than unity. Values of these figures of merit for iodine concentrations of 5, 20, and 300 mg/cm3 are given in the paper. The process of division appears to be advantageous as a signal-to-noise enhancer for all applications not requiring a quantitative relationship between image contrast and photon flux.
journal_name
Med Physjournal_title
Medical physicsauthors
Baily NA,Rimkus D,Nalcioglu Odoi
10.1118/1.595289subject
Has Abstractpub_date
1983-01-01 00:00:00pages
25-8issue
1eissn
0094-2405issn
2473-4209journal_volume
10pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2912178
更新日期:2008-06-01 00:00:00
abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594312
更新日期:1977-09-01 00:00:00
abstract:PURPOSE:Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3602456
更新日期:2011-07-01 00:00:00
abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2779862
更新日期:2007-10-01 00:00:00
abstract::Increasing output resolution is assumed to improve noise characteristics of a CCD digitizer. In this work, however, we have found that as the quantization step becomes lower than the analog noise (present in the signal before its conversion to digital) the noise reduction becomes significantly lower than expected. Tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1644672
更新日期:2004-03-01 00:00:00
abstract:PURPOSE:To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. METHODS:Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4718680
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Positron emission tomography (PET) is an important tool for nuclear medical imaging. It has been widely used in clinical diagnosis, scientific research, and drug testing. PET is a kind of emission computed tomography. Its basic imaging principle is to use the positron annihilation radiation generated by radionu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13804
更新日期:2019-11-01 00:00:00
abstract::This paper examines the distributions of the SAR (specific absorption rate) ratio and temperature elevation when an ultrasound beam propagates through the interface of muscle and bone. This interface is regarded as a flat boundary to partition the energy of the ultrasound beam, and the analytical solution of temperatu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598979
更新日期:2000-05-01 00:00:00
abstract:PURPOSE:The most appropriate method of evaluating the effective atomic number necessitates consideration of energy-dependent behavior. Previously, this required quite laborious calculation, which is why many scientists revert to over-simplistic power-law methods. The purpose of this work is to develop user-friendly sof...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3689810
更新日期:2012-04-01 00:00:00
abstract:PURPOSE:It is estimated that 7% of women in the western world will develop palpable breast cysts in their lifetime. Even though cysts have been correlated with risk of developing breast cancer, many of them are benign and do not require follow-up. We develop a method to discriminate benign solitary cysts from malignant...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12110
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:To determine the diagnostic efficacy of optical coherence tomography (OCT) to identify cervical intraepithelial neoplasia (CIN) grade 2 or higher by computer-aided diagnosis (CADx). METHODS:OCT has been investigated as a screening/diagnostic tool in the management of preinvasive and early invasive cancers of t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3523098
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:The purpose of this work was to generate uncompressed heterogeneous breast phantom models using size-dependent fibroglandular distributions derived from a large cohort of breast CT (bCT) datasets, and to compare differences in normalized glandular dose coefficients for bCT "DgNCT " when the realistic heterogene...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13391
更新日期:2019-03-01 00:00:00
abstract:PURPOSE:To investigate whether building a knowledge-based planning (KBP) model with prostate bed plans constructed from constrained hierarchical optimization (CHO) would result in more efficient model construction with more consistent output than a model built using plans from a traditional, trial-and-error-based optim...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13163
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:The purpose of this study was to detect and analyze anomalies between a large number of computed tomography (CT) scanners, tracked over time, utilized to collect human pulmonary CT data for a national multicenter study: chronic obstructive pulmonary disease genetic epidemiology study (COPDGene). METHODS:A cust...
journal_title:Medical physics
pub_type: 杂志文章,多中心研究
doi:10.1118/1.4747342
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:Proton radiotherapy for head-and-neck cancer (HNC) aims to improve organ-at-risk (OAR) sparing over photon radiotherapy. However, it may be less robust for setup and range uncertainties. The authors investigated OAR sparing and plan robustness for spot-scanning proton planning techniques and compared these with...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4933245
更新日期:2015-11-01 00:00:00
abstract::The aim of the current study was to (a) provide normalized dose data for the estimation of the radiation dose from upper gastrointestinal tract contrast (UGIC) studies carried out to infants and (b) estimate the average patient dose and risks associated with radiation from UGIC examinations performed in our institutio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2181297
更新日期:2006-04-01 00:00:00
abstract::In this article, we present a characterization of the effect of difference of Gaussians (DoG) filters in the detection of mammographic regions. DoG filters have been used previously in mammographic mass computer-aided detection (CAD) systems. As DoG filters are constructed from the subtraction of two bivariate Gaussia...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2358326
更新日期:2006-11-01 00:00:00
abstract:PURPOSE:To formulate convex planning objectives of treatment plan multicriteria optimization with explicit relationships to the dose-volume histogram (DVH) statistics used in plan quality evaluation. METHODS:Conventional planning objectives are designed to minimize the violation of DVH statistics thresholds using pena...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12146
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:The aim of this work is to search for new metrics that could give more reliable acceptance/rejection criteria on the IMRT verification process and to offer solutions to the discrepancies found among different conventional metrics. Therefore, besides conventional metrics, new ones are proposed and evaluated with...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4964796
更新日期:2016-11-01 00:00:00
abstract::The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and un...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1751251
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:Stereotactic body radiation therapy (SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses, treatments are typically protracted and there are more fields than in conventional radiation treatment schemes. The effect of tem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4709605
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR20,10) for a square field of 10 x 10 cm2 and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3197062
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. METHODS:VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4861818
更新日期:2014-02-01 00:00:00
abstract::The intensity modulated arc has been proposed as an alternative to tomotherapy. Treatment planing systems more typically model the conventional step and shoot or sliding window dynamic multileaf collimator (DMLC) deliveries, and may not support intensity modulated arc therapy (IMAT). As well, another potential drawbac...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1508110
更新日期:2002-10-01 00:00:00
abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598219
更新日期:1998-04-01 00:00:00
abstract::Limiting spatial resolution is a key metric of the quality of magnetic resonance (MR) images, which can provide an indication of the smallest region that can effectively be imaged. In this paper a novel methodology for measuring the limiting spatial resolution of MR images is mathematically analyzed and successfully i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3097633
更新日期:2009-05-01 00:00:00
abstract::Methods for scatter dose calculations in brachytherapy have been developed based on the collapsed cone superposition algorithm. The methods account for effects on the scatter dose caused by the three-dimensional distribution of heterogeneities in the irradiated volume and are considerably faster than methods based on ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1290485
更新日期:2000-10-01 00:00:00
abstract:PURPOSE:To accurately and efficiently implement charged particle transport in a magnetic field in EGSnrc and validate the code for the use in phantom and ion chamber simulations. METHODS:The effect of the magnetic field on the particle motion and position is determined using one- and three-point numerical integrations...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4954318
更新日期:2016-07-01 00:00:00
abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595221
更新日期:1982-03-01 00:00:00
abstract::Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2042248
更新日期:2005-10-01 00:00:00