Simultaneous super-resolution and contrast synthesis of routine clinical magnetic resonance images of the knee for improving automatic segmentation of joint cartilage: data from the Osteoarthritis Initiative.

Abstract:

PURPOSE:High resolution three-dimensional (3D) magnetic resonance (MR) images are well suited for automated cartilage segmentation in the human knee joint. However, volumetric scans such as 3D Double-Echo Steady-State (DESS) images are not routinely acquired in clinical practice which limits opportunities for reliable cartilage segmentation using (fully) automated algorithms. In this work, a method for generating synthetic 3D MR (syn3D-DESS) images with better contrast and higher spatial resolution from routine, low resolution, two-dimensional (2D) Turbo-Spin Echo (TSE) clinical knee scans is proposed. METHODS:A UNet convolutional neural network is employed for synthesizing enhanced artificial MR images suitable for automated knee cartilage segmentation. Training of the model was performed on a large, publically available dataset from the OAI, consisting of 578 MR examinations of knee joints from 102 healthy individuals and patients with knee osteoarthritis. RESULTS:The generated synthetic images have higher spatial resolution and better tissue contrast than the original 2D TSE, which allow high quality automated 3D segmentations of the cartilage. The proposed approach was evaluated on a separate set of MR images from 88 subjects with manual cartilage segmentations. It provided a significant improvement in automated segmentation of knee cartilages when using the syn3D-DESS images compared to the original 2D TSE images. CONCLUSION:The proposed method can successfully synthesize 3D DESS images from 2D TSE images to provide images suitable for automated cartilage segmentation.

journal_name

Med Phys

journal_title

Medical physics

authors

Neubert A,Bourgeat P,Wood J,Engstrom C,Chandra SS,Crozier S,Fripp J

doi

10.1002/mp.14421

subject

Has Abstract

pub_date

2020-10-01 00:00:00

pages

4939-4948

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

47

pub_type

杂志文章
  • A dosimetry review system for cooperative group research.

    abstract::The validity of conclusions drawn from multi-institutional radiotherapy studies is dependent upon the degree to which participating hospitals adhere to study requirements. A major effort undertaken by the Quality Assurance Review Center (QARC) assesses whether or not patient data which are deemed evaluable actually co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595221

    authors: Reinstein LE,McShan D,Glicksman AS

    更新日期:1982-03-01 00:00:00

  • A new framework of image reconstruction from fan beam projections.

    abstract::In this paper, we present a unified framework to reconstruct images for both fan beam and cone beam projections. The important feature of our theoretical framework is that it does not depend on the classical concept of the Radon transform at all. This property allows us to directly generalize the ideas and techniques ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1577252

    authors: Chen GH

    更新日期:2003-06-01 00:00:00

  • An improved bolus configuration for commercial multielement ultrasound and microwave hyperthermia systems.

    abstract::A simple modification is presented for two commercially available hyperthermia applicators which dramatically improves the regulation and dynamic control of the temperature at the bolus/tissue interface. This alteration requires the addition of a variable speed pump, bubble trap, simple heat exchanger, and a few minor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597196

    authors: Diederich CJ,Stauffer PR,Bozzo D

    更新日期:1994-09-01 00:00:00

  • Sci-Thurs PM: Delivery-03: Optical imaging of microscopic radiation dose gradients using a digital microscope.

    abstract::Using superior localization and immobilization methods, stereotactic radiosurgery is capable of delivering spheres of dose as small as a few millimetres in diameter to intracranial targets. For targets abutting critical structures, the most conformal treatments minimize adverse radiation side effects and it is importa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965910

    authors: Keller BM,Peressotti C,Pignol JP

    更新日期:2008-07-01 00:00:00

  • Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy.

    abstract:PURPOSE:To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. METHODS:The DEQCT method was applied to 80/140 kVp images of patient-simulating lumb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4870378

    authors: Goodsitt MM,Shenoy A,Shen J,Howard D,Schipper MJ,Wilderman S,Christodoulou E,Chun SY,Dewaraja YK

    更新日期:2014-05-01 00:00:00

  • SU-E-T-622: A Rapid Hybrid VMAT-IMRT Planning Method Using an Abbreviated Beam Angle Optimization Search.

    abstract:PURPOSE:To generate hybrid VMAT-IMRT treatment plans by utilizing an IMRT beam-angle-optimality (BAO) search under a commercially available TPS without the aid of custom optimization software or high performance computing. METHODS:The high dose modulation provided by IMRT beams can be exploited to improve the quality ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735712

    authors: Schulze D,Ionascu D,Tyagi N

    更新日期:2012-06-01 00:00:00

  • A pencil beam algorithm for magnetic resonance image-guided proton therapy.

    abstract:PURPOSE:The feasibility of magnetic resonance image (MRI)-based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12854

    authors: Padilla-Cabal F,Georg D,Fuchs H

    更新日期:2018-05-01 00:00:00

  • Average glandular dose coefficients for pendant-geometry breast CT using realistic breast phantoms.

    abstract:PURPOSE:To design volume-specific breast phantoms from breast CT (bCT) data sets and estimate the associated normalized mean glandular dose coefficients for breast CT using Monte Carlo methods. METHODS:A large cohort of bCT data sets (N = 215) was used to evaluate breast volume into quintiles (plus the top 5%). The av...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12477

    authors: Hernandez AM,Boone JM

    更新日期:2017-10-01 00:00:00

  • Chord-based image reconstruction in cone-beam CT with a curved detector.

    abstract::Modern computed tomography (CT) scanners use cone-beam configurations for increasing volume coverage, improving x-ray-tube utilization, and yielding isotropic spatial resolution. Recently, there have been significant developments in theory and algorithms for exact image reconstruction from cone-beam projections. In pa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2337270

    authors: Zuo N,Xia D,Zou Y,Jiang T,Pan XC

    更新日期:2006-10-01 00:00:00

  • Ultrasonic tissue characterization via 2-D spectrum analysis: theory and in vitro measurements.

    abstract::A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2436978

    authors: Liu T,Lizzi FL,Ketterling JA,Silverman RH,Kutcher GJ

    更新日期:2007-03-01 00:00:00

  • A fast 4D IMRT/VMAT planning method based on segment aperture morphing.

    abstract:PURPOSE:Four-dimensional volumetric modulated arc therapy (4D VMAT) and four-dimensional intensity-modulated radiotherapy (4D IMRT) are developing radiation therapy treatment strategies designed to maximize dose conformality, minimize normal tissue dose, and deliver the treatment as efficiently as possible. The patient...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12778

    authors: Klawikowski S,Tai A,Ates O,Ahunbay E,Li XA

    更新日期:2018-04-01 00:00:00

  • Towards Data-Efficient Learning: A Benchmark for COVID-19 CT Lung and Infection Segmentation.

    abstract:PURPOSE:Accurate segmentation of lung and infection in COVID-19 computed tomography (CT) scans plays an important role in the quantitative management of patients. Most of the existing studies are based on large and private annotated datasets that are impractical to obtain from a single institution, especially when radi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14676

    authors: Ma J,Wang Y,An X,Ge C,Yu Z,Chen J,Zhu Q,Dong G,He J,He Z,Cao T,Zhu Y,Nie Z,Yang X

    更新日期:2020-12-23 00:00:00

  • Prostatome: a combined anatomical and disease based MRI atlas of the prostate.

    abstract:PURPOSE:In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. St...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881515

    authors: Rusu M,Bloch BN,Jaffe CC,Genega EM,Lenkinski RE,Rofsky NM,Feleppa E,Madabhushi A

    更新日期:2014-07-01 00:00:00

  • Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

    abstract:PURPOSE:The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773866

    authors: Lauzier PT,Chen GH

    更新日期:2013-02-01 00:00:00

  • Dynamic multiatlas selection-based consensus segmentation of head and neck structures from CT images.

    abstract:PURPOSE:Manual delineation of head and neck (H&N) organ-at-risk (OAR) structures for radiation therapy planning is time consuming and highly variable. Therefore, we developed a dynamic multiatlas selection-based approach for fast and reproducible segmentation. METHODS:Our approach dynamically selects and weights the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13854

    authors: Haq R,Berry SL,Deasy JO,Hunt M,Veeraraghavan H

    更新日期:2019-12-01 00:00:00

  • Tolerance design of patient-specific range QA using the DMAIC framework in proton therapy.

    abstract:PURPOSE:To implement the DMAIC (Define-Measure-Analyze-Improve-Control) can be used for customizing the patient-specific QA by designing site-specific range tolerances. METHODS:The DMAIC framework (process flow diagram, cause and effect, Pareto chart, control chart, and capability analysis) were utilized to determine ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12721

    authors: Rah JE,Shin D,Manger RP,Kim TH,Oh DH,Kim DY,Kim GY

    更新日期:2018-02-01 00:00:00

  • Investigation of basic imaging properties in digital radiography. 9. Effect of displayed grey levels on signal detection.

    abstract::Results of an 18-alternative forced-choice experiment have shown that observers were capable of detecting a signal with a contrast of 1 in terms of 10-bit data which were displayed on a CRT monitor with an 8-bit video generator and a window width setting of 1024. We investigated the conditions under which 10-bit signa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595919

    authors: Giger ML,Ohara K,Doi K

    更新日期:1986-05-01 00:00:00

  • On the effective point of measurement in megavoltage photon beams.

    abstract::This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the cham...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2201147

    authors: Kawrakow I

    更新日期:2006-06-01 00:00:00

  • Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

    abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.597605

    authors: Graham LS,Fahey FH,Madsen MT,van Aswegen A,Yester MV

    更新日期:1995-04-01 00:00:00

  • Dosimetric problems at low monitor unit settings for scanned and scattering foil electron beams.

    abstract::Electron beam dosimetry at low monitor unit (MU) settings is important for dosimetric applications. Dose linearity, beam flatness, and beam energies were studied at low MU settings with various dose rates for different types of linear accelerators. It is observed that for the scattering foil units, the dose/MU is a sm...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597328

    authors: Das IJ,Harrington JC,Akber SF,Tomer AF,Murray JC,Cheng CW

    更新日期:1994-06-01 00:00:00

  • Nitroxide conjugate of a thermally responsive elastin-like polypeptide for noninvasive thermometry.

    abstract::Hyperthermia, as an adjuvant with radiation and chemotherapy, has shown promise in the treatment of cancer. The relevant biological effects of a hyperthermia treatment are both time and temperature-dependent, creating a need for accurate thermometry. We present a novel noninvasive thermometry modality that combines a ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1782677

    authors: Dreher MR,Elas M,Ichikawa K,Barth ED,Chilkoti A,Rosen GM,Halpern HJ,Dewhirst M

    更新日期:2004-10-01 00:00:00

  • State-of-the-art in two-dimensional ultrasonic transducer array technology.

    abstract::Attention is given to means of sensing ultrasonic energy distributions over an area. Under the restraints appropiate to real-time imaging of deep body organs, piezoelectric arrays offer the most promising method. Adaptation of integrated circuit techniques to array assembly permits very large arrays of small elements ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594247

    authors: Maginness MG,Plummer JD,Beaver WL,Meindl JD

    更新日期:1976-09-01 00:00:00

  • Benchmarking brachydose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters.

    abstract::In this study, BrachyDose, a recently developed EGSnrc Monte Carlo code for rapid brachytherapy dose calculations, has been benchmarked by reproducing previously published dosimetry parameters for three brachytherapy seeds with varied internal structure and encapsulation. Calculations are performed for two 125I seeds ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2400843

    authors: Taylor RE,Yegin G,Rogers DW

    更新日期:2007-02-01 00:00:00

  • Validation of a deformable image registration technique for cone beam CT-based dose verification.

    abstract:PURPOSE:As radiation therapy evolves toward more adaptive techniques, image guidance plays an increasingly important role, not only in patient setup but also in monitoring the delivered dose and adapting the treatment to patient changes. This study aimed to validate a method for evaluation of delivered intensity modula...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4903292

    authors: Moteabbed M,Sharp GC,Wang Y,Trofimov A,Efstathiou JA,Lu HM

    更新日期:2015-01-01 00:00:00

  • Scatter transmission through an ideal grid.

    abstract::An analytic expression is derived for the transmission of isotropic scattered radiation incident upon an ideal parallel grid. It is found that the expression for the transmission usually found in the literature overestimates the transmission by approximately a factor of two. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594877

    authors: Siddon RL

    更新日期:1981-11-01 00:00:00

  • A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery.

    abstract::The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598962

    authors: Robar JL,Clark BG

    更新日期:2000-05-01 00:00:00

  • A doorless entry system for high-energy radiation therapy rooms.

    abstract::A doorless entry system has been designed for use in high-energy radiation therapy rooms. The doorless entry improves patient access, safety and throughput, increases the physical safety for the radiation therapists, and avoids the significant cost of heavy shielding doors. The design meets concerns relating to radiat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598181

    authors: Dawson DJ,Wissing WW,Tonks RE

    更新日期:1998-02-01 00:00:00

  • Direct-conversion flat-panel imager with avalanche gain: feasibility investigation for HARP-AMFPI.

    abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.3002314

    authors: Wronski MM,Rowlands JA

    更新日期:2008-12-01 00:00:00

  • Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry.

    abstract:PURPOSE:Two diodes which do not require correction factors for small field relative output measurements are designed and validated using experimental methodology. This was achieved by adding an air layer above the active volume of the diode detectors, which canceled out the increase in response of the diodes in small f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4894728

    authors: Charles PH,Cranmer-Sargison G,Thwaites DI,Kairn T,Crowe SB,Pedrazzini G,Aland T,Kenny J,Langton CM,Trapp JV

    更新日期:2014-10-01 00:00:00

  • Evaluation of diffusion models in breast cancer.

    abstract:PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927255

    authors: Panek R,Borri M,Orton M,O'Flynn E,Morgan V,Giles SL,deSouza N,Leach MO,Schmidt MA

    更新日期:2015-08-01 00:00:00