Scatter rejection by electronic collimation.

Abstract:

:An electronic scanning-slit technology is under development which involves replacing paired fore and aft slits for scatter rejection with only one fore slit. As the slit scans across the portion of the patient to be imaged, pulsed x-ray exposures produce images of the slit in successive positions, which are digitized and stored in computer memory. Software techniques are used for tracking the slit image, and discriminating against scatter and veiling glare lying outside the slit image. Such "electronic collimation" does not require synchronization between the slit-scanning and detector readout, which makes it much simpler than alternative methods and potentially adaptable to any digital fluorography system. The performance characteristics of a prototype unit are described and images of a low-contrast phantom are presented.

journal_name

Med Phys

journal_title

Medical physics

authors

Plenkovich D,Sorenson JA,Kruger RA

doi

10.1118/1.595940

subject

Has Abstract

pub_date

1986-03-01 00:00:00

pages

158-63

issue

2

eissn

0094-2405

issn

2473-4209

journal_volume

13

pub_type

杂志文章
  • Knowledge-based segmentation of thoracic computed tomography images for assessment of split lung function.

    abstract::The assessment of differential left and right lung function is important for patients under consideration for lung resection procedures such as single lung transplantation. We developed an automated, knowledge-based segmentation algorithm for purposes of deriving functional information from dynamic computed tomography...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598898

    authors: Brown MS,Goldin JG,McNitt-Gray MF,Greaser LE,Sapra A,Li KT,Sayre JW,Martin K,Aberle DR

    更新日期:2000-03-01 00:00:00

  • Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studies.

    abstract::We applied Monte Carlo methods for the simulation of x-ray scattering in water phantoms. The phantom thickness was varied from 5 to 20 cm, and the monoenergetic incident x rays were varied from 15 to 100 keV. Eight screen pairs and a total absorption system were used as x-ray receptors. We determined the angular, spec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595771

    authors: Chan HP,Doi K

    更新日期:1985-03-01 00:00:00

  • A comparative contrast-detail study of five medical displays.

    abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2868780

    authors: Samei E,Ranger NT,Delong DM

    更新日期:2008-04-01 00:00:00

  • Development of a flexible optical fiber based high resolution integrated PET∕MRI system.

    abstract:PURPOSE:The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET∕MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4757911

    authors: Yamamoto S,Watabe H,Kanai Y,Watabe T,Aoki M,Sugiyama E,Kato K,Hatazawa J

    更新日期:2012-11-01 00:00:00

  • Transrectal electrical impedance tomography of the prostate: spatially coregistered pathological findings for prostate cancer detection.

    abstract:PURPOSE:Prostate cancer ranks as one of the most common malignancies and currently represents the second leading cancer-specific cause of death in men. The current use of single modality transrectal ultrasound (TRUS) for biopsy guidance has a limited sensitivity and specificity for accurately identifying cancerous lesi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4803498

    authors: Wan Y,Borsic A,Heaney J,Seigne J,Schned A,Baker M,Wason S,Hartov A,Halter R

    更新日期:2013-06-01 00:00:00

  • Deterministic photon kerma distribution based on the Boltzmann equation for external beam radiation therapy.

    abstract::A photon transport algorithm for fully three-dimensional radiotherapy treatment planning has been developed based on the discrete ordinates (SN) solution of the Boltzmann equation. The algorithm is characterized by orthogonal adaptive meshes, which place additional points where large gradients occur and a procedure to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2960247

    authors: Yuan J,Jette D,Chen W

    更新日期:2008-09-01 00:00:00

  • The effect of angular spread on the intensity distribution of arbitrarily shaped electron beams.

    abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596252

    authors: Mohan R,Chui CS,Fontenla D,Han K,Ballon D

    更新日期:1988-03-01 00:00:00

  • Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array.

    abstract:PURPOSE:To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3310806

    authors: Cheong KH,Kang SK,Lee M,Kim SS,Park S,Hwang TJ,Kim KJ,Oh DH,Bae H,Suh TS

    更新日期:2010-03-01 00:00:00

  • Assessment of image quality and scatter and leakage radiation of an integrated MR-LINAC system.

    abstract:PURPOSE:To assess the image quality, scatter, and leakage radiation of an integrated magnetic resonance linear accelerator (MR-LINAC or MRL) system. METHODS:A large American College of Radiology (ACR) magnetic resonance imaging (MRI) accreditation phantom was used to evaluate the MRI capabilities of the integrated MRL...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12767

    authors: Wang J,Yung J,Kadbi M,Hwang K,Ding Y,Ibbott GS

    更新日期:2018-03-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • A controlled phantom study of a noise equalization algorithm for detecting microcalcifications in digital mammograms.

    abstract::We report on some extensions and further developments of a well-known microcalcification detection algorithm based on adaptive noise equalization. Tissue equivalent phantom images with and without labeled microcalcifications were subjected to this algorithm, and analyses of results revealed some shortcomings in the ap...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1359245

    authors: Gürün OO,Fatouros PP,Kuhn GM,de Paredes ES

    更新日期:2001-04-01 00:00:00

  • Investigation of gamma knife image registration errors resulting from misalignment between the patient and the imaging axis.

    abstract::The ability of Leksell GammaPlan to perform stereotactic space localizations with image sets where there is misalignment of the patient's head (stereotactic frame and fiducial apparatus) relative to the computed tomography (CT) scanner coordinate system was studied. Misalignment is sometimes necessary for patient comf...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2179751

    authors: Cernica G,Wang Z,Malhotra H,de Boer S,Podgorsak MB

    更新日期:2006-04-01 00:00:00

  • High-speed photography during ultrasound illustrates potential therapeutic applications of microbubbles.

    abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2133718

    authors: Postema M,van Wamel A,ten Cate FJ,de Jong N

    更新日期:2005-12-01 00:00:00

  • The use of a diode matrix in commissioning activities for electron energies > or = 9 MeV: a feasibility study.

    abstract::The contribution of a commercially available diode matrix (MapCHECK, provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3081414

    authors: Borca VC,Pasquino M,Ozzello F,Tofani S

    更新日期:2009-04-01 00:00:00

  • The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy.

    abstract::Intensity modulated radiation therapy (IMRT) is used to deliver highly conformal radiation doses to tumors while sparing nearby sensitive tissues. Discrepancies between calculated and measured dose distributions have been reported for regions of high dose gradients corresponding to complex radiation fluence patterns. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1812851

    authors: Bergman AM,Otto K,Duzenli C

    更新日期:2004-12-01 00:00:00

  • A novel 3D printing method for accurate anatomy replication in patient-specific phantoms.

    abstract:PURPOSE:A novel 3D printing method has been developed, which employs human CT images to construct patient specific phantoms by controlling the filament extrusion rate. METHODS:An in-house software was developed comprising pixel-by-pixel (PbP) reading of the Hounsfield Units (HU) values in the original patient DICOM im...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13154

    authors: Okkalidis N

    更新日期:2018-10-01 00:00:00

  • SU-D-211-06: The Effect of Motion in RapidArc Lung SBRT Delivery.

    abstract:PURPOSE:RapidArc is routinely used for stereotactic radiotherapy for lung cancer. While treatment dose is optimized and calculated on a static CT image, the motion of the target in conjunction with the motion of the MLC may Result in a delivered dose deviating from the planed dose. In this study, we investigate the dos...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734660

    authors: Zou J,Yin L,Shen J,Corradetti M,Kirk M,Rengan R,Teo BK

    更新日期:2012-06-01 00:00:00

  • Energy spectrum based calculation of the half and the tenth value layers for brachytherapy sources using a semiempirical parametrized mass attenuation coefficient formulism.

    abstract::As different types of radionuclides (e.g., 131Cs source) are introduced for clinical use in brachytherapy, the question is raised regarding whether a relatively simple method exists for the derivation of values of the half value layer (HVL) or the tenth value layer (TVL). For the radionuclide that has been clinically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2905356

    authors: Yue NJ

    更新日期:2008-06-01 00:00:00

  • A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.

    abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13276

    authors: Shan J,Sio TT,Liu C,Schild SE,Bues M,Liu W

    更新日期:2019-01-01 00:00:00

  • Experimental study of the relationship between the base impedance and its time derivative in impedance plethysmography.

    abstract::Transthoracic electrical impedance Z consists of a constant baseline component Z0 and the time variable component delta Z such that Z = Z0 + delta Z. The first time derivative of Z has a negative peak, the magnitude of which is (dZ/dt)min. Measurements of 170 volunteers show that (dZ/dt)min is a function of the consta...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594910

    authors: Djordjevich L,Sadove MS

    更新日期:1981-01-01 00:00:00

  • Comparison of secondary neutron dose in proton therapy resulting from the use of a tungsten alloy MLC or a brass collimator system.

    abstract:PURPOSE:To apply the dual ionization chamber method for mixed radiation fields to an accurate comparison of the secondary neutron dose arising from the use of a tungsten alloy multileaf collimator (MLC) as opposed to a brass collimator system for defining the shape of a therapeutic proton field. METHODS:Hydrogenous an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3656025

    authors: Diffenderfer ES,Ainsley CG,Kirk ML,McDonough JE,Maughan RL

    更新日期:2011-11-01 00:00:00

  • A new open-source GPU-based microscopic Monte Carlo simulation tool for the calculations of DNA damages caused by ionizing radiation - Part II: sensitivity and uncertainty analysis.

    abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14036

    authors: Lai Y,Tsai MY,Tian Z,Qin N,Yan C,Hung SH,Chi Y,Jia X

    更新日期:2020-04-01 00:00:00

  • Automatic exposure control in multichannel CT with tube current modulation to achieve a constant level of image noise: experimental assessment on pediatric phantoms.

    abstract::Automatic exposure control (AEC) systems have been developed by computed tomography (CT) manufacturers to improve the consistency of image quality among patients and to control the absorbed dose. Since a multichannel helical CT scan may easily increase individual radiation doses, this technical improvement is of speci...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2746492

    authors: Brisse HJ,Madec L,Gaboriaud G,Lemoine T,Savignoni A,Neuenschwander S,Aubert B,Rosenwald JC

    更新日期:2007-07-01 00:00:00

  • Monitoring radiation use in cardiac fluoroscopy imaging procedures.

    abstract:PURPOSE:Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry o...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3524224

    authors: Stevens NT,Steiner SH,Smith IR,MacKay RJ

    更新日期:2011-01-01 00:00:00

  • Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum.

    abstract:PURPOSE:A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x ra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3223357

    authors: Marziani M,Taibi A,Di Domenico G,Gambaccini M

    更新日期:2009-10-01 00:00:00

  • Projections onto the Pareto surface in multicriteria radiation therapy optimization.

    abstract:PURPOSE:To eliminate or reduce the error to Pareto optimality that arises in Pareto surface navigation when the Pareto surface is approximated by a small number of plans. METHODS:The authors propose to project the navigated plan onto the Pareto surface as a postprocessing step to the navigation. The projection attempt...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4930252

    authors: Bokrantz R,Miettinen K

    更新日期:2015-10-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • A limit on dose reduction possible with CT reconstruction algorithms without prior knowledge of the scan subject.

    abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4941954

    authors: Hsieh SS,Chesler DA,Fleischmann D,Pelc NJ

    更新日期:2016-03-01 00:00:00

  • Dosimetric aspects of a 3.3-MV linear accelerator.

    abstract::Both the design considerations and the dosimetric properties of the Siemens Model 5800 linear accelerator are discussed. This unit is of such an energy (3.3 MV) as to imitate Cobalt-60 teletherapy depth doses. A linear relation of dmax to depth dose at low energies was found for various wave guides and targets. The en...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596487

    authors: Steidley KD,Rosen CW

    更新日期:1990-05-01 00:00:00

  • Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl.

    abstract::Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3036117

    authors: Arvanitis CD,Bohndiek SE,Blakesley J,Olivo A,Speller RD

    更新日期:2009-01-01 00:00:00