Evaluation of diffusion models in breast cancer.

Abstract:

PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing gradient ranges were explored in phantom studies. METHODS:The effect of eddy currents and accuracy of b-value determination using a multiple b-value diffusion-weighted MR imaging sequence were investigated in test objects. Diffusion model selection and noise were then investigated in volunteers (n = 5) and breast tumor patients (n = 21) using the Bayesian information criterion. RESULTS:54.3% of lesion voxels were best fitted by a monoexponential, 26.2% by a stretched-exponential, and 19.5% by a biexponential intravoxel incoherent motion (IVIM) model. High correlation (0.92) was observed between diffusion coefficients calculated using mono- and stretched-exponential models and moderate (0.59) between monoexponential and IVIM (medians: 0.96/0.84/0.72 × 10(-3) mm(2)/s, respectively). Distortion due to eddy currents depended on the direction of the diffusion gradient and displacement varied between 1 and 6 mm for high b-value images. Shift in the apparent diffusion coefficient due to intrinsic field gradients was compensated for by averaging diffusion data obtained from opposite directions. CONCLUSIONS:Pseudodiffusion and intravoxel heterogeneity effects were not observed in approximately half of breast cancer and normal tissue voxels. This result indicates that stretched and IVIM models should be utilized in regional analysis rather than global tumor assessment. Cross terms between diffusion-sensitization gradients and other imaging or susceptibility-related gradients are relevant in clinical protocols, supporting the use of geometric averaging of diffusion-weighted images acquired with diffusion-sensitization gradients in opposite directions.

journal_name

Med Phys

journal_title

Medical physics

authors

Panek R,Borri M,Orton M,O'Flynn E,Morgan V,Giles SL,deSouza N,Leach MO,Schmidt MA

doi

10.1118/1.4927255

subject

Has Abstract

pub_date

2015-08-01 00:00:00

pages

4833-9

issue

8

eissn

0094-2405

issn

2473-4209

journal_volume

42

pub_type

杂志文章
  • Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.

    abstract:PURPOSE:High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process contr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4901520

    authors: Létourneau D,Wang A,Amin MN,Pearce J,McNiven A,Keller H,Norrlinger B,Jaffray DA

    更新日期:2014-12-01 00:00:00

  • SU-E-T-429: Image-Guided Eye Plaque Brachytherapy Optimization: Implications for Patients at 2-Year Follow-up.

    abstract:PURPOSE:Episcleral eye plaque brachytherapy has been utilized in the treatment of intra-ocular malignancies, delivering large prescription doses to the apex of the tumor. Advances in dose calculation and image guidance, via calibrated fundus images, enable localization of the tumor and determination of dose to the macu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735518

    authors: Guida K,Niermann K,Malcolm A,Sternberg P,Munn G,Coffey C

    更新日期:2012-06-01 00:00:00

  • The role of water desorption on optical clearing of biotissue: studied with near infrared reflectance spectroscopy.

    abstract::In order to understand the role of water desorption, i.e., the opposite of water adsorption, in optical clearing of biological tissue created by the application of hyperosmotic agents, dynamics of water loss in fresh porcine muscle tissue administrated with glycerol or ethylene glycol was investigated with the near-in...

    journal_title:Medical physics

    pub_type:

    doi:10.1118/1.1576228

    authors: Xu X,Wang RK

    更新日期:2003-06-01 00:00:00

  • Effects of point configuration on the accuracy in 3D reconstruction from biplane images.

    abstract::Two or more angiograms are being used frequently in medical imaging to reconstruct locations in three-dimensional (3D) space, e.g., for reconstruction of 3D vascular trees, implanted electrodes, or patient positioning. A number of techniques have been proposed for this task. In this simulation study, we investigate th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2008467

    authors: Dmochowski J,Hoffmann KR,Singh V,Xu J,Nazareth DP

    更新日期:2005-09-01 00:00:00

  • Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans.

    abstract::Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in the early detection of lung cancer in radiographs and computed tomography (CT) images. In order to improve sensitivity for nodule detection, many researchers have employed a filter as a preprocessing step for enhancement of nodules. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1581411

    authors: Li Q,Sone S,Doi K

    更新日期:2003-08-01 00:00:00

  • A new pulse sequence for determining T1 and T2 simultaneously.

    abstract::Determination of the relaxation times T1 and T2 which are important for tissue characterization generally requires the use of different pulse sequences in magnetic resonance imaging. In this study, a new pulse sequence which facilitates simultaneous determination of the T1 and T2 times is presented. Determination take...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595867

    authors: Graumann R,Fischer H,Oppelt A

    更新日期:1986-09-01 00:00:00

  • Iterative reconstruction method for light emitting sources based on the diffusion equation.

    abstract::Bioluminescent imaging (BLI) of luciferase-expressing cells in live small animals is a powerful technique for investigating tumor growth, metastasis, and specific biological molecular events. Three-dimensional imaging would greatly enhance applications in biomedicine since light emitting cell populations could be unam...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2138007

    authors: Slavine NV,Lewis MA,Richer E,Antich PP

    更新日期:2006-01-01 00:00:00

  • Use of capillary optics as a beam intensifier for a Compton x-ray source.

    abstract::The use of Kumakhov capillary optics will significantly enhance the performance of near-monochromatic, Compton backscattered x-ray programs. The Vanderbilt University Medical Free-Electron Laser Center is developing the capability to create these tunable x rays for medical imaging. The present transport has only refle...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597218

    authors: Tompkins PA,Abreu CC,Carroll FE,Xiao QF,MacDonald CA

    更新日期:1994-11-01 00:00:00

  • Determination of primary dose in 60Co gamma beam using a small attenuator.

    abstract::A measurement technique previously proposed for determining dose from primary radiation has been tested using 60Co gamma rays. It is shown that the dose from primary radiation is reliably determined for field sizes of 10 X 10 and 20 X 20 cm2 at depths of 0.5, 5, and 10 cm in water. With further development this techni...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596534

    authors: Nizin PS,Kase KR

    更新日期:1990-01-01 00:00:00

  • Monte Carlo study of ionization chamber magnetic field correction factors as a function of angle and beam quality.

    abstract:PURPOSE:To use EGSnrc Monte Carlo simulations for magnetic field dosimetry to determine optimal measurement orientations, calculate beam quality conversion factors for 32 cylindrical and three parallel-plate (PP) ion chambers, evaluate the beam quality and angular dependence of these factors, and examine the magnetic f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12716

    authors: Malkov VN,Rogers DWO

    更新日期:2018-02-01 00:00:00

  • Poster - Thurs Eve-04: Mathematical modeling of liver metastases tumour growth and control with radiotherapy.

    abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965923

    authors: Campbell A,Davidson M,Lock M,Wong E

    更新日期:2008-07-01 00:00:00

  • GateCT™ surface tracking system for respiratory signal reconstruction in 4DCT imaging.

    abstract:PURPOSE:To assess the temporal and spatial accuracy of the GateCT™ system (VisionRT, London, UK), a recently released respiratory tracking system for 4DCT, under both ideal and nonideal respiratory conditions. METHODS:Three experiments were performed by benchmarking and comparing its results with the ground-truth inpu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3671941

    authors: Kauweloa KI,Ruan D,Park JC,Sandhu A,Kim GY,Pawlicki T,Watkins WT,Song B,Song WY

    更新日期:2012-01-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • Predicting 3D body shape and body composition from conventional 2D photography.

    abstract:PURPOSE:Total and regional body composition are important indicators of health and mortality risk, but their measurement is usually restricted to controlled environments in clinical settings with expensive and specialized equipment. A method that approaches the accuracy of the current gold standard method, dual-energy ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14492

    authors: Tian IY,Ng BK,Wong MC,Kennedy S,Hwaung P,Kelly N,Liu E,Garber AK,Curless B,Heymsfield SB,Shepherd JA

    更新日期:2020-12-01 00:00:00

  • Fast cross-projection algorithm for reconstruction of seeds in prostate brachytherapy.

    abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1489044

    authors: Narayanan S,Cho PS,Marks RJ 2nd

    更新日期:2002-07-01 00:00:00

  • Computerized analysis of mammographic microcalcifications in morphological and texture feature spaces.

    abstract::We are developing computerized feature extraction and classification methods to analyze malignant and benign microcalcifications on digitized mammograms. Morphological features that described the size, contrast, and shape of microcalcifications and their variations within a cluster were designed to characterize microc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598389

    authors: Chan HP,Sahiner B,Lam KL,Petrick N,Helvie MA,Goodsitt MM,Adler DD

    更新日期:1998-10-01 00:00:00

  • Predicting high-intensity focused ultrasound thalamotomy lesions using 2D magnetic resonance thermometry and 3D Gaussian modeling.

    abstract:PURPOSE:To develop a method of using two-dimensional (2D) magnetic resonance thermometry, and three-dimensional (3D) Gaussian modeling to predict the volume, shape, and location of 1 day postoperative T1w high-intensity focused ultrasound lesions in medication refractory tremor patients; thereby facilitating a better c...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13868

    authors: Seasons GM,Mazerolle EL,Sankar T,Martino D,Kiss ZHT,Pichardo S,Pike GB

    更新日期:2019-12-01 00:00:00

  • Beam shaper with optimized dose utility for helical cone-beam CT.

    abstract:PURPOSE:To develop a new design of an x-ray beam shaper for helical computed tomography (CT) that increases the dose utilization. METHODS:For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e.,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3577766

    authors: Köhler T,Brendel B,Proksa R

    更新日期:2011-07-01 00:00:00

  • Technical Note: On maximizing Cherenkov emissions from medical linear accelerators.

    abstract:PURPOSE:Cherenkov light during MV radiotherapy has recently found imaging and therapeutic applications but is challenged by relatively low fluence. Our purpose is to investigate the feasibility of increasing Cherenkov light production during MV radiotherapy by increasing photon energy and applying specialized beam-hard...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12927

    authors: Shrock Z,Yoon SW,Gunasingha R,Oldham M,Adamson J

    更新日期:2018-07-01 00:00:00

  • A statistical approach to infer the minimum setup distance of a well chamber to the wall or to the floor for 192Ir HDR calibration.

    abstract::We propose a new method based on statistical analysis technique to determine the minimum setup distance of a well chamber used in the calibration of 192Ir high dose rate (HDR). The chamber should be placed at least this distance away from any wall or from the floor in order to mitigate the effect of scatter. Three dif...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2911156

    authors: Chang L,Ho SY,Chui CS,Lee JH,Du YC,Chen T

    更新日期:2008-06-01 00:00:00

  • Computer-aided detection of breast cancers using Haar-like features in automated 3D breast ultrasound.

    abstract:PURPOSE:Automated 3D breast ultrasound (ABUS) has gained interest in breast imaging. Especially for screening women with dense breasts, ABUS appears to be beneficial. However, since the amount of data generated is large, the risk of oversight errors is substantial. Computer aided detection (CADe) may be used as a secon...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4914162

    authors: Tan T,Mordang JJ,van Zelst J,Grivegnée A,Gubern-Mérida A,Melendez J,Mann RM,Zhang W,Platel B,Karssemeijer N

    更新日期:2015-04-01 00:00:00

  • 2-Step IMAT and 2-Step IMRT: a geometrical approach.

    abstract::The purpose of this paper is to develop a method that reduces the number of segments for intensity modulated arc therapy (IMAT) and intensity modulated radiotherapy (IMRT) for concave target volumes (TV). The aim was to utilize no more than two intensity levels per organ at risk (OAR) and to derive both optimal segmen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1861161

    authors: Bratengeier K

    更新日期:2005-03-01 00:00:00

  • A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.

    abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773883

    authors: Gete E,Duzenli C,Milette MP,Mestrovic A,Hyde D,Bergman AM,Teke T

    更新日期:2013-02-01 00:00:00

  • Vessel size measurements in angiograms: manual measurements.

    abstract::Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical pra...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1562491

    authors: Hoffmann KR,Dmochowski J,Nazareth DP,Miskolczi L,Nemes B,Gopal A,Wang Z,Rudin S,Bednarek DR

    更新日期:2003-04-01 00:00:00

  • Model-based geometric calibration for medical x-ray systems.

    abstract:PURPOSE:Currently applied calibration approaches lead to satisfying 3D roadmapping overlay and 3D reconstruction accuracies; however, the required calibration times are extensive. The aim of this paper is the introduction of a novel model-based approach for geometric system calibrations, leading to a significant reduct...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4931964

    authors: van der Maas R,de Jager B,Steinbuch M,Dries J

    更新日期:2015-11-01 00:00:00

  • A novel curvilinear approach for prostate seed implantation.

    abstract:PURPOSE:A new technique called "curvilinear approach" for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. METHODS:Twenty LDR prostate brachytherapy cases planned intraopera...

    journal_title:Medical physics

    pub_type: 杂志文章,随机对照试验

    doi:10.1118/1.3694110

    authors: Podder TK,Dicker AP,Hutapea P,Darvish K,Yu Y

    更新日期:2012-04-01 00:00:00

  • Computational analysis and dosimetric evaluation of a commercial irregular-fields computer program.

    abstract::The proper evaluation of the accuracy of a new computer program for radiation-therapy dosimetry requires consideration of both the mathematical algorithm used in the program and the performance required in clinical applications. As an example, our evaluation of the irregular-fields dosimetry program currently marketed...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594344

    authors: Hallberg JR,Ibbott GS,Carson PL,Hendee WR

    更新日期:1977-11-01 00:00:00

  • Computerized detection of masses in digital mammograms: automated alignment of breast images and its effect on bilateral-subtraction technique.

    abstract::An automated technique for the alignment of right and left breast images has been developed for use in the computerized analysis of bilateral breast images. In this technique, the breast region is first identified in each digital mammogram by use of histogram analysis and morphological filtering operations. The anteri...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597307

    authors: Yin FF,Giger ML,Doi K,Vyborny CJ,Schmidt RA

    更新日期:1994-03-01 00:00:00

  • Improving the calibration of radiochromic films by the use of uncertainties in optical density and dose.

    abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4811238

    authors: Garcia LI,Azorin JF

    更新日期:2013-07-01 00:00:00

  • Transverse axial film tomography with a therapy simulator.

    abstract::A tomographic attachment was designed and developed that attaches to our existing simulator. The film tomograms obtained with the aid of this device exhibit very low geometrical distortion and good contrast and resolution for the objects used in this investigation. In addition, our results to date show that adjacent a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594662

    authors: Kessaris ND,Harisiadis L

    更新日期:1980-03-01 00:00:00