Abstract:
:Single photon emission computed tomography (SPECT) was investigated for imaging on-board radiation therapy machines in order to localize functional and molecular targets. A computer-simulated female NCAT phantom was positioned supine on a flat-top treatment couch. Twenty tumor locations were defined in the upper torso. The eight lung tumors were subject to the effects of respiratory motion. Tumor diameters of 10.8, 14.4, and 21.6 mm were simulated for tumor-to-background ratios of 3:1 and 6:1 that are characteristic of the radiotracer 99mTc-sestamibi. Projection images representing scan times of 4, 8, and 20 min were simulated for an anterior, half-circular trajectory. Images were reconstructed with attenuation correction by ordered-subsets expectation maximization (OSEM) using six subsets and five iterations. Contrast-to-noise ratios (CNRs) were calculated from ensembles of 25 images. Cross correlation with a noise-free tumor template was used to select the most suspicious tumor location within a 14.4-mm-radius search volume surrounding each tumor, with only that one tumor in each search volume. Localization accuracy was assessed by calculating average distances between measured and true tumor locations. Localization accuracy and CNRs were strongly affected by tumor location relative to the detector trajectory. For example, CNR values near the chest wall were greater by a factor of 3.5 than for tumors near the spine and posterior ribs, a much greater effect than the factor of 1.6 difference in CNR between 6:1 and 3:1 tumor uptakes. Typically, tumors of 6:1 uptake were localized as accurately with 4 min of scan time as tumors of 3:1 uptake that had been imaged for 20 min. Using 4 min scans, 14.4 and 21.6 mm anterior tumors of 6:1 uptake were localized within 2 mm. These results suggest that SPECT, on-board radiation therapy machines, may be a viable modality for localizing certain functional and molecular targets using relatively short scan times.
journal_name
Med Physjournal_title
Medical physicsauthors
Roper J,Bowsher J,Yin FFdoi
10.1118/1.3113902subject
Has Abstractpub_date
2009-05-01 00:00:00pages
1727-35issue
5eissn
0094-2405issn
2473-4209journal_volume
36pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:To investigate the accuracy of output factor measurements using a commercial (Exradin W1, SI) and a prototype, "in-house" developed, plastic scintillation dosimeter (PSD) in small photon fields. METHODS:Repetitive detector-specific output factor OFdet measurements were performed in water (parallel to the CAX) ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12064
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:To compare how the inclusion of the uncertainties in dose and optical density affects the results of the calibration of Gafchromic(®) EBT3 radiochromic films. METHODS:Five methods of least square minimization were compared for calibration of radiochromic films. These differed in the way in which the uncertaint...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4811238
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:Deformable image registration (DIR) is often validated based on a distance-to-agreement (DTA) criterion of automatically propagated anatomical landmarks that were manually identified. Due to human observer variability, however, the performance of the registration method is diluted. The purpose of this study was...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4760990
更新日期:2012-11-01 00:00:00
abstract::A method for optimizing MR imaging pulse sequence parameters in a statistical framework is presented. Parameters are defined to be optimal when the resulting scalar images yield optimal image segmentations using Bayesian pixel classification. Thus, Bayes risk is used as the objective function to minimize. Approximatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597425
更新日期:1995-10-01 00:00:00
abstract::To improve beam penetration into a head allowing the treatment of deeper seated tumors, two neutron collimators were built sequentially and tested for use in the clinical boron neutron capture therapy (BNCT) program at the epithermal neutron irradiation facility of the Brookhaven Medical Research Reactor. The collimat...
journal_title:Medical physics
pub_type: 临床试验,杂志文章
doi:10.1118/1.597772
更新日期:1996-12-01 00:00:00
abstract::Various techniques have been developed to localize radioactive sources in brachytherapy implants. The most common methods include the orthogonal film method, the stereo-shift film method, and recently, direct localization from a series of contiguous CT transverse images. The major advantage of the CT method is that it...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598548
更新日期:1999-04-01 00:00:00
abstract:PURPOSE:To introduce a novel laser-based optical-CT scanner for the readout of three-dimensional (3D) radiation dosimeters. METHODS:The scanner employs a diode laser, a cylindrical lens, a motorized linear rail, a rotation stage, and a charge-coupled device camera. The scanner operates in a translate-rotate fashion an...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3538924
更新日期:2011-02-01 00:00:00
abstract::The focal spot of a linear accelerator is often considered to have a fully stable position. In practice, however, the beam control loop of a linear accelerator needs to stabilize after the beam is turned on. As a result, some motion of the focal spot might occur during the start-up phase of irradiation. When acquiring...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1576229
更新日期:2003-06-01 00:00:00
abstract:PURPOSE:The study aims to investigate whether Nakagami parameters--estimated from the statistical distribution of the backscattered ultrasound radio-frequency (RF) signals--could provide a means for quantitative characterization of parotid-gland injury resulting from head-and-neck radiotherapy. METHODS:A preliminary c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4862507
更新日期:2014-02-01 00:00:00
abstract::Recently, the clinical application of electronic portal imaging devices has enabled more frequent verification of patient setup for radiation treatment. However, the image quality has sometimes proven to be inadequate, motivating the investigation of alternative sensors with better image quality. Amorphous selenium (a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598219
更新日期:1998-04-01 00:00:00
abstract:PURPOSE:We studied the sensitivity of a novel transmission fiber scintillator array designed and built for in line treatment verification. The purpose of this project is to assess the capability of the fiber detector array technology to detect treatment errors in real time without false positives to enhance patient saf...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735217
更新日期:2012-06-01 00:00:00
abstract::A realistic photon beam model based on Monte Carlo simulation of clinical linear accelerators was implemented in a convolution/superposition dose calculation algorithm. A primary and an extra-focal sources were used in this beam model to represent the direct photons from the target and the scattered photons from other...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598111
更新日期:1997-12-01 00:00:00
abstract:PURPOSE:Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4868693
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13731
更新日期:2019-10-01 00:00:00
abstract::This paper compares the characteristics of three types of commercial p-type electron diodes specially designed for in vivo dosimetry (Scanditronix EDD2, Sun Nuclear QED 111200-0 and PTW T60010E diodes coupled with a Therados DPD510 dosimeter) in electron fields with energies from 4.5 to 21 MeV, and in conditions simil...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1630492
更新日期:2004-01-01 00:00:00
abstract::This paper investigates the effect of the waterproofing sleeve on the calibration of kilovoltage photon beams (50-300 kV). The sleeve effect correction factor, ps has been calculated using the Monte Carlo method as the ratios of the air kerma in an air cavity of a cylindrical chamber without the waterproofing sleeve t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598039
更新日期:1997-09-01 00:00:00
abstract::The American Association of Physicists in Medicine recommends that the reference dose-rate distribution, used for treatment planning for low-energy photon brachytherapy sources in routine clinical use, must be based on at least two independent determinations: one using experimentally measured dose rates and one using ...
journal_title:Medical physics
pub_type: 指南,杂志文章
doi:10.1118/1.1690712
更新日期:2004-05-01 00:00:00
abstract:PURPOSE:The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET∕MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4757911
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To investigate the feasibility of using the high Zeff storage phosphor material BaFBrI:Eu2+ in conjunction with the low Zeff storage phosphor material KCl:Eu2+ for simultaneous proton dose and linear energy transfer (LET) measurements by 1) measuring the fundamental optical and dosimetric properties of BaFBrI:E...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14748
更新日期:2021-02-01 00:00:00
abstract::The nucletron Leipzig applicator is designed for (HDR) 192Ir brachy radiotherapy of surface lesions. The dosimetric characteristics of this applicator were investigated using simulation method based on Monte Carlo N-particle (MCNP) code and phantom measurements. The simulation method was validated by comparing calcula...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1812609
更新日期:2004-12-01 00:00:00
abstract::Molecular imaging is the direct or indirect noninvasive monitoring and recording of the spatial and temporal distribution of in vivo molecular, genetic, and/or cellular processes for biochemical, biological, diagnostic, or therapeutic applications. Molecular images that indicate the presence of malignancy can be acqui...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4819818
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). METHODS:Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963213
更新日期:2016-10-01 00:00:00
abstract::A method is described for obtaining S values between a tumor and its host organ for use with the MIRD formalism. It applies the point-source specific absorbed fractions for an infinite water medium, tabulated by Berger, to a rectangular solid of arbitrary dimensions which contains a rectangular tumor of arbitrary dime...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596732
更新日期:1991-05-01 00:00:00
abstract::Our purpose in this paper is to present an in vivo dosimetry program designed both for measuring the rectal dose and for avoiding misadministrations in gynecological intracavitary implants. A device containing an energy compensated diode was specially designed for these measurements. Our calibration procedure as well ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598598
更新日期:1999-05-01 00:00:00
abstract::The authors are investigating the concept of a direct-conversion flat-panel imager with avalanche gain for low-dose x-ray imaging. It consists of an amorphous selenium (a-Se) photoconductor partitioned into a thick drift region for x-ray-to-charge conversion and a relatively thin region called high-gain avalanche rush...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.3002314
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:Colitis refers to inflammation of the inner lining of the colon that is frequently associated with infection and allergic reactions. In this paper, we propose deep convolutional neural networks methods for lesion-level colitis detection and a support vector machine (SVM) classifier for patient-level colitis dia...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12399
更新日期:2017-09-01 00:00:00
abstract::Three-dimensional water phantoms are routinely used when acquiring the data necessary to commission medical linear accelerators. A new water phantom controller has been developed at our institution that is unique in several aspects. The water phantom controller is based on an IBM XT compatible computer. This has been ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596414
更新日期:1989-01-01 00:00:00
abstract::A double-mirror multilayer monochromator was developed for the purpose of irradiating live cell cultures at the Synchrotron Radiation Center, University of Wisconsin-Madison. The monochromator is designed for the soft x-ray region with photon energies between 270 and 2400 eV. Multilayer mirrors with 55 bilayers of W/C...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598259
更新日期:1998-05-01 00:00:00
abstract:PURPOSE:Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based te...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4935199
更新日期:2015-12-01 00:00:00
abstract::The objective of this work is to assess the suitability and performance of a new dosimeter system with a novel geometry for the quality assurance (QA) of volumetric modulated arc therapy (VMAT). The new dosimeter system consists of a hollow cylinder (15 and 25 cm inner and outer diameters) with 124 diodes embedded in ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3117563
更新日期:2009-05-01 00:00:00