Abstract:
PURPOSE:To develop an individually optimized contrast-enhanced (CE) 4D-computed tomography (CT) for radiotherapy simulation in pancreatic ductal adenocarcinomas (PDA). METHODS:Ten PDA patients were enrolled. Each underwent three CT scans: a 4D-CT immediately following a CE 3D-CT and an individually optimized CE 4D-CT using test injection. Three physicians contoured the tumor and pancreatic tissues. Image quality scores, tumor volume, motion, tumor-to-pancreas contrast, and contrast-to-noise ratio (CNR) were compared in the three CTs. Interobserver variations were also evaluated in contouring the tumor using simultaneous truth and performance level estimation. RESULTS:Average image quality scores for CE 3D-CT and CE 4D-CT were comparable (4.0 and 3.8, respectively; P = 0.082), and both were significantly better than that for 4D-CT (2.6, P < 0.001). Tumor-to-pancreas contrast results were comparable in CE 3D-CT and CE 4D-CT (15.5 and 16.7 Hounsfield units (HU), respectively; P = 0.21), and the latter was significantly higher than in 4D-CT (9.2 HU, P = 0.001). Image noise in CE 3D-CT (12.5 HU) was significantly lower than in CE 4D-CT (22.1 HU, P = 0.013) and 4D-CT (19.4 HU, P = 0.009). CNRs were comparable in CE 3D-CT and CE 4D-CT (1.4 and 0.8, respectively; P = 0.42), and both were significantly better in 4D-CT (0.6, P = 0.008 and 0.014). Mean tumor volumes were significantly smaller in CE 3D-CT (29.8 cm3, P = 0.03) and CE 4D-CT (22.8 cm3, P = 0.01) than in 4D-CT (42.0 cm3). Mean tumor motion was comparable in 4D-CT and CE 4D-CT (7.2 and 6.2 mm, P = 0.17). Interobserver variations were comparable in CE 3D-CT and CE 4D-CT (Jaccard index 66.0% and 61.9%, respectively) and were worse for 4D-CT (55.6%) than CE 3D-CT. CONCLUSIONS:CE 4D-CT demonstrated characteristics comparable to CE 3D-CT, with high potential for simultaneously delineating the tumor and quantifying tumor motion with a single scan.
journal_name
Med Physjournal_title
Medical physicsauthors
Choi W,Xue M,Lane BF,Kang MK,Patel K,Regine WF,Klahr P,Wang J,Chen S,D'Souza W,Lu Wdoi
10.1118/1.4963213subject
Has Abstractpub_date
2016-10-01 00:00:00pages
5659issue
10eissn
0094-2405issn
2473-4209journal_volume
43pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::A simple approach was developed that calculates the output factors and tissue maximum ratio of an asymmetric field at any point within the open field, and specifically both at the central axis (when the jaws do not shadow it) and at the effective center of the open field, using the existing tables for symmetric fields...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597524
更新日期:1995-01-01 00:00:00
abstract:PURPOSE:The purpose of the paper was to use a virtual phantom to identify a set of radiomic features from T1-weighted and T2-weighted magnetic resonance imaging (MRI) of the brain which is stable to variations in image acquisition parameters and to evaluate the effect of image preprocessing on radiomic features stabili...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13834
更新日期:2019-11-01 00:00:00
abstract::Luminance scatter fractions were measured for patients and phantoms in various regions of the chest film. Scatter fractions were found to be highly variable, being quite high in the regions of the chest with a large equivalent tissue thickness (e.g. mediastinum, chest wall, and subdiaphragmatic areas). For example, ap...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595027
更新日期:1981-09-01 00:00:00
abstract:OBJECTIVES:To evaluate the performance of RapidArc® (Eclipse 10.0.28) and SmartArc® (Pinnacle 9.0) radiotherapy plans for lung stereotactic body radiation therapy (SBRT) in terms of dosimetric plan quality, delivery efficiency, inhomogeneity corrections and accuracy of dose delivery using a custom-built heterogeneity i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740172
更新日期:2012-07-01 00:00:00
abstract::A 4 x 500 mm2 "cloverleaf" low energy germanium detector array has been assembled for the purpose of in vivo bone lead measurement through x-ray fluorescence. Using 109Cd as an exciting source, results are reported from a leg phantom simulating measurement of lead in a human tibia. For high activity (4.0-4.4 GBq) and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2436973
更新日期:2007-03-01 00:00:00
abstract::Previous ultrasound tomography work conducted by our group showed a direct correlation between measured sound speed and physical density in vitro, and increased in vivo sound speed with increasing mammographic density, a known risk factor for breast cancer. Building on these empirical results, the purpose of this work...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2964092
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:To examine schemes to grade the severity of metal susceptibility artifacts on image quality using cardiac MRI pulse sequences. METHODS:A post-thoracotomy patient was simulated with a stainless steel sternal wire (Syneture,MA; size=6, diameter=48mm), placed securely on an ACR MRI phantom. Phantom was scanned on...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734785
更新日期:2012-06-01 00:00:00
abstract::The dose received in the buildup region outside the primary beam has been measured for 60Co gamma rays and 6- and 18-MV X rays. The variation of this dose with field size and depth was evaluated. The effect of blocking trays and the importance of their design was determined. ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595508
更新日期:1984-05-01 00:00:00
abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598325
更新日期:1998-08-01 00:00:00
abstract:PURPOSE:To correlate the Cole relaxation frequencies obtained from measurements of the electrical properties of breast tissue to the presence or absence of cancer. METHODS:Four-lead impedance measurements were obtained on ex vivo specimens extracted during surgery from 187 volunteer patients. Data were acquired with a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4725172
更新日期:2012-07-01 00:00:00
abstract:PURPOSE:To find an upper bound on the maximum dose reduction possible for any reconstruction algorithm, analytic or iterative, that result from the inclusion of the data statistics. The authors do not analyze noise reduction possible from prior knowledge or assumptions about the object. METHODS:The authors examined th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4941954
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:Coronary x-ray computed tomography angiography (CCTA) is used to non-invasively assess coronary artery geometry and has, combined with computational modeling, demonstrated the potential to identify physiologically significant lesions. These measurements require robust and accurate coronary imaging and delineati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12295
更新日期:2017-07-01 00:00:00
abstract:PURPOSE:Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3426000
更新日期:2010-08-01 00:00:00
abstract:PURPOSE:Adding magnetic resonance (MR)-derived information to standard transrectal ultrasound (TRUS) images for guiding prostate biopsy is of substantial clinical interest. A tumor visible on MR images can be projected on ultrasound (US) by using MR-US registration. A common approach is to use surface-based registratio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4917481
更新日期:2015-05-01 00:00:00
abstract::Due to practical limitations such as inter- and intraleaf transmission, nondivergent leaf end design, and leaf scatter, multileaf collimators (MLCs) are unable to accurately produce the ideal fluence patterns generated by inverse planning systems. Consequently, low dose regions receive substantially more radiation tha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2779862
更新日期:2007-10-01 00:00:00
abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13299
更新日期:2019-02-01 00:00:00
abstract::Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are pre...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2198168
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:Multiple anatomy optimization (MAO) utilizing deformable dose accumulation on entire 4DCT data sets is implemented to overcome ambiguity between optimal dose defined on a single anatomy and optimal accumulated dose resulting from dose delivery to moving and deforming anatomy. METHODS:Six lung cancer patients a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735744
更新日期:2012-06-01 00:00:00
abstract::Stereotactic Body Radiation Therapy (SBRT) is an important form of cancer therapy with increasingly broad application across a spectrum of tumor types in primary and metastatic settings. In this presentation the radiation biology, clinical experience from various trials, and cautionary updates on normal tissue toleran...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735812
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905050
更新日期:2015-02-01 00:00:00
abstract::We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in t...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1949750
更新日期:2005-08-01 00:00:00
abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13643
更新日期:2019-09-01 00:00:00
abstract:PURPOSE:To reduce image noise and radiation dose in Digital Breast Tomosynthesis (DBT) reconstructions. METHODS:A retrospective study was performed on clinical data sets acquired at a normal dose with Hologic Selenia Dimensions DBT systems. The Prior Image Constrained Compressed Sensing (PICCS) algorithm was used to r...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735982
更新日期:2012-06-01 00:00:00
abstract::We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a w...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596402
更新日期:1989-01-01 00:00:00
abstract:PURPOSE:The goal of this work is to propose a new multichannel method correcting for systematic thickness disturbances and to evaluate its precision in relevant radiation dosimetry applications. METHODS:The eigencolor ratio technique is introduced and theoretically developed to provide a method correcting for thicknes...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.14742
更新日期:2021-02-01 00:00:00
abstract:PURPOSE:Accurate calculation of proton stopping power ratio (SPR) relative to water is crucial to proton therapy treatment planning, since SPR affects prediction of beam range. Current standard practice derives SPR using a single CT scan. Recent studies showed that dual-energy CT (DECT) offers advantages to accurately ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12796
更新日期:2018-04-01 00:00:00
abstract::Statistical image reconstruction (SIR) methods have shown potential to substantially improve the image quality of low-dose x-ray computed tomography (CT) as compared to the conventional filtered back-projection (FBP) method. According to the maximum a posteriori (MAP) estimation, the SIR methods are typically formulat...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1002/mp.13123
更新日期:2018-10-01 00:00:00
abstract:PURPOSE:Distortions in magnetic resonance imaging (MRI) compromise spatial fidelity, potentially impacting delineation and dose calculation. We characterized 2D and 3D large field of view (FOV), sequence-independent distortion at various positions in a 1.0 T high-field open MR simulator (MR-SIM) to implement correction...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4930245
更新日期:2015-10-01 00:00:00
abstract:PURPOSE:We propose a new metric called Distance Discordance (DD), which is defined as the distance between two anatomic points from two moving images, which are co-located on some reference image, when deformed onto another reference image. METHODS:To demonstrate the concept of DD, we created a reference software phan...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4736139
更新日期:2012-06-01 00:00:00
abstract::A method to significantly reduce the exposure area product in fluoroscopy using a pre-patient region-of-interest (ROI) attenuator is presented. The attenuator has a thin central region and a gradually increasing thickness away from the center. It is shown that the unwanted brightening artifact caused by the attenuator...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1470205
更新日期:2002-05-01 00:00:00